Advanced microgrids consisting of distributed energy resources interfaced with multi-inverter systems are becoming more common. Consequently, the effectiveness of voltage and frequency regulation in microgrids using conventional droop-based methodologies is challenged by uncertainty in the sizeand schedule of loads. This article proposes an isochronous architecture of parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter based distributed energyresources (DERs). In spite of not employing explicit control for frequency regulation, this architecture allows even sharing of reactive power while maintaining reduced circulating currents between inverters. The performance is achieved even when there are mismatches between commanded reference and power demanded from the actual load in the network. The isochronous architecture is implemented by employing a global positioning system (GPS) to disseminate timing signals that enable the microgrid to maintain nominal system frequency in the entire network. This enables direct control of active power through voltage source inverter (VSI) output voltage regulation, even in the presence of system disturbances. A small signal eigenvalue analysis of a multi-inverter system near the steady-state operating point is presented to evaluate the stability of the multi-inverter system with the proposed VP-D control. Simulation studies and hardware experiments on an 1.2 kVA prototype are conducted. The effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios are demonstrated. Results of the hardware experiments corroborate the viability of the proposed VP-D control architecture.
This paper presents the novel Droop-e grid-forming inverter control strategy, which establishes an active power-frequency relationship based on an exponential function of the inverter power dispatch. The advantages of this control strategy include an increased utilization of available headroom, mitigated system frequency dynamics, and a natural limiting behavior, all of which are directly compared to the hitherto standard static droop approach. First, the small signal stability of the Droop-e control is assessed on a 3-bus system and found stable across all possible inverter power dispatches. …
We consider the problem of stability analysis for distribution grids with droop-controlled inverters and dynamic distribution power lines. The inverters are modeled as voltage sources with controllable frequency and amplitude. This problem is very challenging for large networks as numerical simulations and detailed eigenvalue analysis are impactical. Motivated by the above limitations, we present in this paper a systematic and computationally efficient framework for stability analysis of inverter-based distribution grids. To design our framework, we use tools from singular perturbation and Lya…
An islanded microgrid supplied by multiple distributed energy resources (DERs) often employs droop-control mechanisms for power sharing. Because microgrids do not include inertial elements, and low pass filtering of noisy measurements introduces lags in control, droop-like controllers may pose significant stability concerns. This paper aims to understand the effects of droop-control on the small-signal stability and transient response of the microgrid. Towards this goal, we present a compendium of results on the small-signal stability of droop-controlled inverter-based microgrids with heteroge…
Recovery of power flow to critical infrastructures, after grid failure, is a crucial need arising in scenarios that are increasingly becoming more frequent. This article proposes a power transition and recovery strategy by proposing a mode-dependent droop control-based inverters. The control strategy of inverters achieves the following objectives 1) regulate the output active and reactive power by the droop-based inverters to a desired value while operating in on-grid mode 2) seamless transition and recovery of power flow injections into the critical loads in the network by inverters operating…
Due to the rise of distributed energy resources, the control of networks of grid-forming inverters is now a pressing issue for power system operation. Droop control is a popular control strategy in the literature for frequency control of these inverters. In this paper, we analyze transient stability in droop-controlled inverter networks that are subject to multiple operating constraints. Using a physically-meaningful Lyapunov-like function, we provide two sets of criteria (one mathematical and one computational) to certify that a post-fault trajectory achieves frequency synchronization while r…
This paper presents a novel control structure and control synthesis method for regulating the output voltage/frequency and power injection of DC-AC inverters. The traditional droop method offers attractive solution to achieve compromise between clashing power and voltage/frequency regulation objectives. However, it relies on use of nonlinear power variables through slow outer control loop. In this paper we formulate the traditional droop method as a feedback control problem based on static power-flow equations and show how neglecting the dynamics of inverter and transmission line restricts the…
Autonomous droop control PV inverters have improved voltage regulation compared to the inverters without grid support functions, but more flexible control techniques will be required as the number of solar photovoltaic (PV) installations increases. This paper studies three inverter future deployment scenarios with droop control inverters, non-exporting inverters, and coordinated inverter control (CIC). The network operation and the interaction between various inverter control methods are studied by simulating inverter operation on two low-voltage networks. Considering 30% PV penetration as the…
The energy mix of future power systems will include high shares of wind power and solar PV. These generation facilities are generally connected via power-electronic inverters. While conventional generation responds dynamically to the state of the electric power system, inverters are power electronic hardware and need to be programmed to react to the state of the system. Choosing an appropriate control scheme and the corresponding parameters is necessary to guarantee that the system operates safely. A prominent control scheme for inverters is droop control, which mimics the response of conventi…
This letter proposes a general decentralized control of cascaded inverters-power factor angle droop control. Compared to the existing control strategies, it has the following attractive benefits: 1) it is suitable for both grid-connected and islanded modes; 2) Seamless transition between different modes can be obtained; 3) stability condition in the grid-connected mode is independent of the transmission line impedance; 4) it is suited for any types of loads in islanded modes; 5) multi-equilibrium point problem is avoided; 6) it is suitable for four quadrant operation. The small signal stabilit…
Inverter-based resources (IBR) have been widely studied for their advantages on the current power systems. This increase in the penetration of renewable energy has raised some concerns about the stability of the existing grid. Historically, power systems are dominated by synchronous generators that can easily react to system instability due to high inertia and damping characteristics. However, with IBR, the control of the inverter plays a crucial role in contributing to the system stability and enhancing the functionality of the inverters. One of these novel control methods is droop control. D…
A new method for the stability assessment of inverter-based microgrids is presented in this paper. Directly determining stability boundaries by searching the multidimensional space of inverters' droop gains is a computationally prohibitive task. Instead, we build a certified stability region by utilizing a generalized Laplacian matrix eigenvalues, which are a measure of proximity to stability boundary. We establish an upper threshold for the eigenvalues that determines the stability boundary of the entire system and demonstrate that this value depends only on the network's R/X ratio but does n…
Hybrid systems combine both discrete and continuous state dynamics. Power electronic inverters are inherently hybrid systems: they are controlled via discrete-valued switching inputs which determine the evolution of the continuous-valued current and voltage state dynamics. Hybrid systems analysis could prove increasingly useful as large numbers of renewable energy sources are incorporated to the grid with inverters as their interface. In this work, we explore a hybrid systems approach for the stability analysis of power and power electronic systems. We provide an analytical proof showing that …
Unlike conventional generators, inverter-based generation do not possess any rotational inertia. While grid-forming inverters can synthesize small (virtual) inertia via advanced feedback control loops, additional control mechanisms are needed to ensure safety and security of the power grid during transients. In this paper, we propose novel real-time safety-constrained feedback controllers ("safety filters") for droop-based (grid-forming) inverters to ensure transient security of the grid. The safety filter acts as a buffer between the network operational layer and the inverter-control layer, a…
With increased attention on grid-forming inverters as a power system stabilizing device during periods of high shares of inverter-based resource operations, there is a present need for a transparent and rigorous investigation of the inverted and direct power to frequency control capabilities, and associated impacts, of these devices on hybrid systems. Here, analysis of the frequency dynamics of the droop controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for no…
Virtual oscillator control is the latest control technique for grid-forming inverters. Virtual Oscillator based Controllers (VOCs) provide all the steady-state droop functionalities of conventional droop controllers and, in addition, the time-domain synchronization with a connected electrical network. However, existing literature does not consider the aspect of dynamic control over the voltage stiffness of a VOC. Voltage stiffness is a vital parameter for a grid-forming inverter. If the voltage stiffness is too high, the inverter picks up all the reactive power demand of the PCC. In contrast, …
For power grids predominantly featuring large synchronous generators (SGs), there exists a significant body of work bridging optimization and control tasks. A generic workflow in such efforts entails: characterizing the steady state of control algorithms and SG dynamics; assessing the optimality of the resulting operating point with respect to an optimal dispatch task; and prescribing control parameters to ensure that (under reasonable ambient perturbations) the considered control nudges the system steady state to optimality. Well studied instances of the aforementioned approach include design…
This paper investigates the transient stability of power systems co-dominated by different types of grid-forming (GFM) devices. Synchronous generators (SGs and VSGs) and droop-controlled inverters are typical GFM devices in modern power systems. SGs/VSGs are able to provide inertia while droop-controlled inverters are generally inertialess. The transient stability of power systems dominated by homogeneous GFM devices has been extensively studied. Regarding the hybrid system jointly dominated by heterogeneous GFM devices, the transient stability is rarely reported. This paper aims to fill this …
A new method for stability assessment of inverter-based microgrids is presented in this paper. It leverages the notion of critical clusters -- a localized group of inverters with parameters having the highest impact on the system stability. The spectrum of the weighted network admittance matrix is proposed to decompose a system into clusters and rank them based on their distances from the stability boundary. We show that each distinct eigenvalue of this matrix is associated with one cluster, and its eigenvectors reveal a set of inverters that participate most in the corresponding cluster. The …
The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated the accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low inertia offered by the power electronics interfaced energy resources however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop controller paramet…
A widely embraced approach to mitigate the dynamic degradation in low-inertia power systems is to mimic generation response using grid-connected inverters to restore the grid's stiffness. In this paper, we seek to challenge this approach and advocate for a principled design based on a systematic analysis of the performance trade-offs of inverter-based frequency control. With this aim, we perform a qualitative and quantitative study comparing the effect of conventional control strategies --droop control (DC) and virtual inertia (VI)-- on several performance metrics induced by $\mathcal L_2$ and…
Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt-Var and Volt-Watt control curves are used to analytically derive a stability criterion using \lyapnouv analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be repres…
Power electronic converters for integrating renewable energy resources into power systems can be divided into grid-forming and grid-following inverters. They possess certain similarities, but several important differences, which means that the relationship between them is quite subtle and sometimes obscure. In this article, a new perspective based on duality is proposed to create new insights. It successfully unifies the grid interfacing and synchronization characteristics of the two inverter types in a symmetric, elegant, and technology-neutral form. Analysis shows that the grid-forming and g…
In commercial inverters, an LCL filter is considered an integral part to filter out the switching harmonics and generate a sinusoidal output voltage. The existing literature on the averaged virtual oscillator controller (VOC) dynamics is for current feedback before the output LCL filter that contains the switching harmonics or for inductive filters ignoring the effect of filter capacitance. In this work, a new version of averaged VOC dynamics is presented for islanded inverters with current feedback after the LCL filter thus avoiding the switching harmonics going into the VOC. The embedded dro…
A Control Architecture for Fast Frequency Regulation with Increasing Penetration of Inverter Based Resources (Extended Version)
Massachusetts Institute of Technology(麻省理工学院);King Fahd University of Petroleum & Minerals(法赫德国王石油与矿产大学);King Abdulaziz City for Science and Technology(阿卜杜勒阿齐兹国王科学与技术城)
As more inverter-connected renewable resources are integrated into the grid, frequency stability may degrade because of the reduction in mechanical inertia and damping. A common approach to mitigate this degradation in performance is to use the power electronic interfaces of the renewable resources for primary frequency control. Since inverter-connected resources can realize almost arbitrary responses to frequency changes, they are not limited to reproducing the linear droop behaviors. To fully leverage their capabilities, reinforcement learning (RL) has emerged as a popular method to design n…
The issues of uncertainty and frequency security could become significantly serious in power systems with the high penetration of volatile inverter-based renewables (IBRs). These issues make it necessary to consider the uncertainty and frequency-related constraints in the economic dispatch (ED) programs. However, existing ED studies rarely proactively optimize the control parameters of inverter-based resources related to fast regulation (e.g., virtual inertia and droop coefficients) in cooperation with other dispatchable resources to improve the system frequency security and dispatch reliabili…