arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2102.12332eess.SYcs.SY
收藏

电力电子主导的电力系统中并网逆变器与同步发电机相互作用的功频动态特性

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

Rick Wallace Kenyon, Amirhossein Sajadi, Matt Bossart, Andy Hoke, Bri-Mathias Hodge

摘要:

随着越来越多的注意力在电网形成逆变器作为电力系统稳定设备期间的逆变器为基础的资源操作的高份额,有一个目前需要一个透明的和严格的调查逆变和直接的功率频率控制能力,以及相关的影响,这些设备上的混杂系统。在这里,下垂控制的并网逆变器和同步发电机的频率动态分析阐明了逆变的有功功率-频率关系和频率响应阶数减少,形成了新的非线性频率下垂控制方法的基础。设备级电磁暂态域仿真证实了降阶的结果,建立了一个适当设计的直流侧系统有一个可以忽略不计的动态影响有功功率传输,不会妨碍频率调节,并确认频率响应的改善与非线性控制。9节点和39节点测试系统的仿真验证了大型网络中频率的最低点和变化率的降阶和相关解耦。主系统振荡模式证实了高份额的电网形成逆变器和增加模式频率和阻尼之间的相关性;阻尼急剧下降,观察份额超过80%,无论是在大型网络或额定值变化的电网形成设备的数量在一个小的测试系统。最后,在夏威夷毛伊岛的仿真结果表明,一阶频率响应与电网形成逆变器的趋势,进一步证实了分析结果和网络的影响。

英文摘要:

With increased attention on grid-forming inverters as a power system stabilizing device during periods of high shares of inverter-based resource operations, there is a present need for a transparent and rigorous investigation of the inverted and direct power to frequency control capabilities, and associated impacts, of these devices on hybrid systems. Here, analysis of the frequency dynamics of the droop controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, non-linear frequency droop control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed DC-side system has a negligible dynamical impact on active power transfer and will not impede frequency regulation, and confirm the frequency response improvement with non-linear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in large networks. The primary system oscillatory mode confirms the correlation between high shares of grid-forming inverters and increased mode frequency and damping; a sharp decrease in damping is observed at shares above 80%, whether by grid-forming device quantity in large networks or rating variations in a small test system. Finally, simulation results on the Hawaiian island of Maui show a trend towards a first order frequency response with a grid-forming inverter, further corroborating the analytic findings and network impacts.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑