Modern safety-critical energy infrastructures are increasingly operated in a hierarchical and modular control framework which allows for limited data exchange between the modules. In this context, it is important for each module to synthesize and communicate constraints on the values of exchanged information in order to assure system-wide safety. To ensure transient safety in inverter-based microgrids, we develop a set invariance-based distributed safety verification algorithm for each inverter module. Applying Nagumo's invariance condition, we construct a robust polynomial optimization problem to jointly search for safety-admissible set of control set-points and design parameters, under allowable disturbances from neighbors. We use sum-of-squares (SOS) programming to solve the verification problem and we perform numerical simulations using grid-forming inverters to illustrate the algorithm.
This paper proposes a novel transient stability assessment tool for networked microgrids based on neural Lyapunov methods. Assessing transient stability is formulated as a problem of estimating the dynamic security region of networked microgrids. We leverage neural networks to learn a local Lyapunov function in the state space. The largest security region is estimated based on the learned neural Lyapunov function, and it is used for characterizing disturbances that the networked microgrids can tolerate. The proposed method is tested and validated in a grid-connected microgrid, three networked …
This work explores the usage of a supplementary controller for improving the transient performance of inverter$\unicode{x2013}$based resources (IBR) in microgrids. The supplementary controller is trained using a reinforcement learning (RL)$\unicode{x2013}$based algorithm to minimize transients in a power converter connected to a microgrid. The controller works autonomously to issue adaptive, intermediate set points based on the current state and trajectory of the observed or tracked variable. The ability of the designed controller to mitigate transients is verified on a medium voltage test sys…
We consider the problem of guaranteeing that the transient voltages and currents stay within prescribed bounds in Direct Current (DC) microgrids, when the controller does not have access to accurate system dynamics due to the load being unknown and/or time-varying. To achieve this, we propose an optimization based controller design using control barrier functions. We show that the proposed controller has a decentralized structure and is robust with respect to the uncertainty in the precise values of the system parameters, such as the load.
Modularized Koopman Bilinear Form (M-KBF) is presented to model and predict the transient dynamics of microgrids in the presence of disturbances. As a scalable data-driven approach, M-KBF divides the identification and prediction of the high-dimensional nonlinear system into the individual study of subsystems; and thus, alleviating the difficulty of intensively handling high volume data and overcoming the curse of dimensionality. For each subsystem, Koopman bilinear form is applied to efficiently identify its model by developing eigenfunctions via the extended dynamic mode decomposition method…
Whenever stability of a system is concerned, transient stability is given the highest priority. For analysis purpose transient stability is checked with the help of Critical Clearing Time (CCT). With the continuous growth of Distributed Generation (DG) concept, the need of a stable industrial microgrid is a necessity. This paper studies the effect of Solar PV as DG unit on CCT during islanded operation of an industrial microgrid system. In primary analysis a single centralized Solar PV unit along with the Synchronous Generator (SG) is used. Then multiple PV units distributed at random location…
A Physics-Informed Dynamic Graph Neural Network (PIDGeuN) is presented to accurately, efficiently and robustly predict the nonlinear transient dynamics of microgrids in the presence of disturbances. The graph-based architecture of PIDGeuN provides a natural representation of the microgrid topology. Using only the state information that is practically measurable, PIDGeuN employs a time delay embedding formulation to fully reproduce the system dynamics, avoiding the dependency of conventional methods on internal dynamic states such as controllers. Based on a judiciously designed message passing …
Critical energy infrastructures are increasingly relying on advanced sensing and control technologies for efficient and optimal utilization of flexible energy resources. Algorithmic procedures are needed to ensure that such systems are designed to be resilient to a wide range of cyber-physical adversarial events. This paper provides a robust optimization framework to quantify the range of adversarial perturbations that a system can accommodate without violating pre-specified resiliency metrics. An inner-approximation of the set of adversarial events which can be mitigated by the available flex…
An islanded microgrid supplied by multiple distributed energy resources (DERs) often employs droop-control mechanisms for power sharing. Because microgrids do not include inertial elements, and low pass filtering of noisy measurements introduces lags in control, droop-like controllers may pose significant stability concerns. This paper aims to understand the effects of droop-control on the small-signal stability and transient response of the microgrid. Towards this goal, we present a compendium of results on the small-signal stability of droop-controlled inverter-based microgrids with heteroge…
When planning the investment in Microgrids (MGs), usually static security constraints are included to ensure their resilience and ability to operate in islanded mode. However, unscheduled islanding events may trigger cascading disconnections of Distributed Energy Resources (DERs) inside the MG due to the transient response, leading to a partial or full loss of load. In this paper, a min-max-min, hybrid, stochastic-robust investment planning model is proposed to obtain a resilient MG considering both High-Impact-Low-Frequency (HILF) and Low-Impact-High-Frequency (LIHF) uncertainties. The HILF u…
This paper proposes a holistic framework for parameter coordination of a power electronic-interfaced microgrid interconnection against natural disasters. The paper identifies a transient stability issue in a microgrid interconnection. Based on recent advances in control theory, we design a framework that can systematically coordinate system parameters, such that post-disaster equilibrium points of microgrid interconnections are asymptotically stable. The core of the framework is a stability assessment algorithm using sum of squares programming. The efficacy of the proposed framework is tested …
The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated the accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low inertia offered by the power electronics interfaced energy resources however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop controller paramet…
This research addresses distributed proportional power sharing of inverter-based Distributed Generators (DGs) in microgrids under variations in maximum power capacity of DGs. A microgrid can include renewable energy resources such as wind turbines, solar panels, fuel cells, etc. The intermittent nature of such energy resources causes variations in their maximum power capacities. Since DGs in microgrids can be regarded as Multi-Agent-Systems (MASs), a consensus algorithm is designed to have the DGs generate their output power in proportion to their maximum capacities under capacity fluctuations…
In this study, we propose a decision-making strategy for pinning-based distributed multi-agent (PDMA) automatic generation control (AGC) in islanded microgrids against stochastic communication disruptions. The target microgrid is construed as a cyber-physical system, wherein the physical microgrid is modeled as an inverter-interfaced autonomous grid with detailed system dynamic formulation, and the communication network topology is regarded as a cyber-system independent of its physical connection. The primal goal of the proposed method is to decide the minimum number of generators to be pinned…
Inverter-connected resources can improve transient stability in low-inertia grids by injecting active power to minimize system frequency deviations following disturbances. In practice, most generation and load disturbances are step changes and the engineering figure-of-merit is often the peak overshoot in frequency resulting from these step disturbances. In addition, the inverter-connected resources tend to saturate much more easily than conventional synchronous machines. However, despite these challenges, standard controller designs must deal with averaged quantities through $H_2$ or $H_\inft…
This project discusses the control schemes for distribution grids with a large amount of wind penetration. Microgrids are constantly gaining popularity, especially in the countries, where there is energy crisis. Various systems, including synchronous generators, grid and loads, have been investigated in this project. Major focus is placed on active and reactive power sharing. Droop control for multiple synchronous generators is explored. The phenomenon of load transients has also been reviewed and associated simulations have been carried out on SimPower Systems. Constant wind power has been in…
Unlike conventional generators, inverter-based generation do not possess any rotational inertia. While grid-forming inverters can synthesize small (virtual) inertia via advanced feedback control loops, additional control mechanisms are needed to ensure safety and security of the power grid during transients. In this paper, we propose novel real-time safety-constrained feedback controllers ("safety filters") for droop-based (grid-forming) inverters to ensure transient security of the grid. The safety filter acts as a buffer between the network operational layer and the inverter-control layer, a…
Invariance is Compositional for Continuous-time Systems: From Sleekness to Lebesgue Density
College of Computing, University Mohammed VI Polytechnic (UM6P)(Mohammed VI Polytechnic大学计算学院);Univ. Grenoble Alpes(格勒诺布尔阿尔卑斯大学);CNRS(法国国家科学研究中心);Grenoble INP(格勒诺布尔国立理工学院);Laboratory of Signals and Systems (L2S)(信号与系统实验室);CentraleSupélec(中央理工-高等电力学院);Paris-Saclay University(巴黎萨克雷大学)
This paper presents an improved active disturbance rejection control scheme (IFO-ADRC) with an improved fractional-order extended state observer (IFO-ESO). The structural information of the system is utilized in IFO-ESO rather than buried as in the typical fractional-order extended state observer (FO-ESO) and help significantly improve the performance of IFO-ESO and closed-loop system. Compared with the integer-order active disturbance rejection controller (IO-ADRC), the auxiliary tracking controller of IFO-ADRC has a simpler form and fewer parameters need to be tuned. Frequency-domain analysi…
In this paper, we consider the problem of verifying safety constraint satisfaction for single-input single-output systems with uncertain transfer function coefficients. We propose a new type of barrier function based on a vector norm. This type of barrier function has a measurable upper bound without full state availability. An identifier-based estimator allows an exact bound for the uncertainty-based component of the barrier function estimate. Assuming that the system is safe initially allows an exponentially decreasing bound on the error due to the estimator transient. Barrier function and e…
The current context of launchers reusability requires the improvement of control algorithms for their liquid-propellant rocket engines. Their transient phases are generally still performed in open loop. In this paper, it is aimed at enhancing the control performance and robustness during the fully continuous phase of the start-up transient of a generic gas-generator cycle. The main control goals concern end-state tracking in terms of combustion-chamber pressure and chambers mixture ratios, as well as the verification of a set of hard operational constraints. A controller based on a nonlinear p…