The value of the scaling parameter $E_{\text{eff}}$ of the temperature dependence for current generated in silicon bulk is investigated for highly irradiated devices.
Measurements of devices irradiated to fluences above $1 \times 10^{15} n_{\text{eq}} \text{cm}^{-2} $ have shown a different temperature scaling behaviour than devices irradiated to lower fluences. This paper presents the determination of the parameter $E_{\text{eff}}$ for diodes irradiated with protons up to fluences of $3 \times 10^{15} n_{\text{eq}} \text{cm}^{-2}$ in the bias range from $0$V to $1000$V at temperatures from $-36 ^{\circ}\text{C}$ to $0 ^{\circ}\text{C}$ at different stages of annealing. It is shown that $E_{\text{eff}}$ for highly irradiated devices depends on the applied electric field: below depletion voltage, $E_{\text{eff}}$ is observed to have a lower value than above depletion voltage
Capacitance-voltage (CV) measurements are a widely used technique in silicon detector physics. It gives direct information about the full depletion voltage and the effective doping concentration. However, for highly irradiated sensors, the measured data differs significantly from the usual shape which makes the extraction of the afore mentioned parameters less precise to not possible. We present an explanation for the obseved frequency dependence and based on that, a method to extract the desired sensor parameters.
The understanding of the weighting field of irradiated silicon sensors is essential for calculating the response of silicon detectors in the radiation environment at accelerators like at the CERN LHC. Using 1-D calculations of non-irradiated pad sensors and 1-D TCAD simulations of pad sensors before and after irradiation, it is shown that the time-dependence of the weighting field is related to the resistivity of low field regions with ohmic behaviour in the sensor. A simple formula is derived, which relates the time constant of the time-dependent weighting field, $τ$, with the resistivity and…
A method is presented which allows to obtain the position-dependent electric field and charge density by fits to velocity profiles from edge-TCT data from silicon strip-detectors. The validity and the limitations of the method are investigated by simulations of non-irradiated $n^+p$ pad sensors and by the analysis of edge-TCT data from non-irradiated $n^+p$ strip-detectors. The method is then used to determine the position dependent electric field and charge density in $n^+p$ strip detectors irradiated by reactor neutrons to fluences between 1 and $10 \times 10^{15}$ cm$^{-2}$ for forward-bias…
We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states and the trapping of charge carriers can be tuned to produce a good description of the measured charge collection profiles in the fluence range from 0.5x10^{14} Neq/cm^2 to 5.9x10^{14} Neq/cm^2. The model correctly predicts the variation in the profiles as the temperature is changed from -10C to -25C. The measured charge collection profiles are inconsistent wit…
Future experiments are using silicon detectors in a high radiation environment and in high magnetic fields. The radiation tolerance of silicon improves by cooling it to temperatures below 180 K. At low temperatures the mobility increases, which leads to larger deflections of the charge carriers by the Lorentz force. A good knowledge of the Lorentz angle is needed for design and operation of silicon detectors. We present measurements of the Lorentz angle between 77 K and 300 K before and after irradiation with a primary beam of 21 MeV protons.
An external magnetic field exerts a Lorentz force on drifting electric charges inside a silicon strip sensor and thus shifts the cluster position of the collected charge. The shift can be related to the Lorentz angle which is typically a few degrees for holes and a few tens of degrees for electrons in a 4 T magnetic field. The Lorentz angle depends upon magnetic field, electric field inside the sensor and temperature. In this study the sensitivity to radiation for fluences up to 10^16 n/cm^2 has been studied. The Lorentz shift has been measured by inducing ionization with 670 nm red or 1070 nm…
A new method for the extraction of the electric field in the bulk of heavily irradiated silicon pixel sensors is presented. It is based on the measurement of the Lorentz deflection and mobility of electrons as a function of depth. The measurements were made at the CERN H2 beam line, with the beam at a shallow angle with respect to the pixel sensor surface. The extracted electric field is used to simulate the charge collection and the Lorentz deflection in the pixel sensor. The simulated charge collection and the Lorentz deflection is in good agreement with the measurements both for non-irradia…
The Silicon Drift Detectors will equip two of the six cylindrical layers of high precision position sensitive detectors in the ITS of the ALICE experiment at LHC. In this paper we report the beam test results of a SDD irradiated with 1 GeV electrons. The aim of this test was to verify the radiation tolerance of the device under an electron fluence equivalent to twice particle fluence expected during 10 years of ALICE operation.
High-energy physics detectors, like Low Gain Avalanche Detectors (LGADs) that will be used as fast timing detectors in the High Luminosity LHC experiments, have to exhibit a significant radiation tolerance. Thereby the impact of radiation on the highly boron-doped gain layer that enables the internal charge multiplication, is of special interest, since due to the so-called Acceptor Removal Effect (ARE) a radiation-induced deactivation of active boron dopants takes place. In this paper we present defect-spectroscopy measurements (Deep-Level Transient Spectroscopy and Thermally Stimulated Curren…
In this paper the results of a beam test characterization campaign of 3D trench silicon pixel sensors are presented. A time resolution in the order of 10 ps was measured both for non-irradiated and irradiated sensors up to a fluence of $2.5 \cdot 10^{16}\,1\,MeV\, n_{eq}\,cm^{-2}$. This feature and a detection efficiency close to $99\%$ make this sensors one of the best candidates for 4D tracking detectors in High-Energy-Physics experiments.
The radiation hardness of the AToM chips of the BaBar Silicon Vertex Tracker has been investigated by means of irradiations with photons from a 60Co source and 0.9 GeV electrons. The increase in noise and the decrease in gain of the amplifier have been measured as a function of the applied capacitive load and the absorbed dose. Different beam intensities have been used to study the effect of different dose rates to the AToM radiation damage. The chip digital functionalities have been tested up to a dose of 5.5 Mrads for the 60Co photons and 9 Mrads for the 0.9 GeV electrons. In addition a pede…
Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Although the physics of Compton scatter is well established, the effects of Compton interactions in the detector on image quality for an edge-on-irradiated silicon detector have still not been thoroughly investigated. Purpose: To investigate and explain effects of Compt…
We are investigating the feasibility of using CMOS foundries to fabricate silicon detectors, both for pixels and for large-area strip sensors. The availability of multi-layer routing will provide the freedom to optimize the sensor geometry and the performance, with biasing structures in poly-silicon layers and MIM-capacitors allowing for AC coupling. A prototyping production of strip test-structures and RD53A compatible pixel sensors was recently completed at LFoundry in a 150$\,$nm CMOS process. This paper will focus on the characterization of irradiated and non-irradiated pixel modules, comp…
We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states and the trapping of charge carriers can be tuned to produce a good description of the measured charge collection profiles in the fluence range from 0.5x10^{14} Neq/cm^2 to 5.9x10^{14} Neq/cm^2. The model correctly predicts the variation in the profiles as the temperature is changed from -10C to -25C. The measured charge collection profiles are inconsistent wit…
We are developing monolithic pixel sensors based on a 0.2 $μ$m fully-depleted Silicon-on-Insulator (SOI) technology for HEP experiment applications. The total ionizing dose (TID) effect is the major issue in the applications for hard radiation environments in HEP experiments. To compensate for TID damage, we have introduced a Double SOI structure which has a Middle Silicon layer (SOI2 layer) in addition. We studied the recovery from TID damage induced by $\mathrm{^{60}Co}~γ$'s and other characteristics of an Integration-type Double SOI sensor. The Double SOI sensor irradiated to 100 kGy showed…
Planar silicon pixel sensors with modified n$^+$-implantation shapes based on the IBL pixel sensor were designed in Dortmund. The sensors with a pixel size of $250\,μ$m $\times$ $50\,μ$m are produced in n$^+$-in-n sensor technology. The charge collection efficiency should improve with electrical field strength maxima created by the different n$^+$-implantation shapes. Therefore, higher particle detection efficiencies at lower bias voltages could be achieved. The modified pixel designs and the IBL standard design are placed on one sensor to test and compare the designs. The sensor can be read o…
During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. Thus, to upgrade the tracker to required performance level, comprehensive measurements and simulations studies have already been carried out. Essential information of the performance of an irradiated silicon detector is obtained by monitoring its charge collection efficiency (CCE). From the evolu…
The absorption length, $λ_{abs}$, of light with wavelengths between 0.95 and 1.30$~μ$m in silicon irradiated with 24$~$GeV/c protons to 1$~$MeV neutron equivalent fluences between 0 and $8.6 \times 10^{15}~$cm$^{-2}$ has been measured. It is found that $λ_{abs}$ decreases with fluence due to radiation-induced defects. A phenomenological parametrisation of the radiation-induced change of $λ_{abs}$ as a function of wavelength and neutron equivalent fluence at room temperature is given. The observation of the decrease of $λ_{abs}$ with irradiation is confirmed by edge-TCT measurements on irradiat…
Within CERN RD50 Collaboration, MCz Si was identified as a best material for the detector used in the high luminosity collider experiments. The n in p Si detectors were utmost radiation hard detectors, which can be used for the phase 2 upgrade plan of the new Compact Muon Solenoid tracker detector in 2026. The choice of n or p-MCz Si material depends upon the high electrical charge collection efficiency performance of these detectors over n or p-FZSi detectors. The bulk radiation damage model for n, p-MCz Si need to develop for the designing, development and optimization of the advanced detect…
In this paper we discuss the measurement of charge collection in irradiated silicon pixel sensors and the comparison with a detailed simulation. The simulation implements a model of radiation damage by including two defect levels with opposite charge states and trapping of charge carriers. The modeling proves that a doubly peaked electric field generated by the two defect levels is necessary to describe the data and excludes a description based on acceptor defects uniformly distributed across the sensor bulk. In addition, the dependence of trap concentrations upon fluence is established by com…
The unique electrical and material properties of 4H-silicon-carbide (4H-SiC) make it a promising candidate material for high rate particle detectors. In contrast to the ubiquitously used silicon (Si), 4H-SiC offers a higher carrier saturation velocity and larger breakdown voltage, enabling a high intrinsic time resolution and mitigating pile-up effects. Additionally, as radiation hardness requirements grow more demanding, wide-bandgap materials such as 4H-SiC could offer better performance. In this work, the detector performance of 50 micron thick 4H-SiC p-in-n planar pad sensors was investiga…
While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.
Charge collection measurements performed on heavily irradiated p-spray dofz pixel sensors with a grazing angle hadron beam provide a sensitive determination of the electric field within the detectors. The data are compared with a complete charge transport simulation of the sensor which includes signal trapping and charge induction effects. A linearly varying electric field based upon the standard picture of a constant type-inverted effective doping density is inconsistent with the data. A two-trap double junction model implemented in ISE TCAD software can be tuned to produce a doubly-peaked el…
The high-luminosity operation of the Tracker in the Compact Muon Solenid (CMS) detector at the Large Hadron Collider (LHC) experiment calls for the development of silicon-based sensors. This involves implementation of AC-coupling to micro-scale pixel sensor areas to provide enhanced isolation of radiation-induced leakage currents. The motivation of this study is the development of AC-pixel sensors with negative oxides (such as aluminium oxide - Al$_2$O$_3$ and hafnium oxide - HfO$_2$) as field insulators that possess good dielectric strength and provide radiation hardness. Thin films of Al$_2$…
The CMS experiment at the LHC includes a hybrid silicon pixel detector for the reconstruction of charged tracks and of the interaction vertices. The barrel region consists of n-in-n sensors with 100X150 um^2 cell size processed on diffusion oxygenated float zone silicon. A biasing grid is implemented and pixel isolation is achieved with the moderated p-spray technique. An extensive test program was carried out on the H2 beam line of the CERN SPS. In this paper we describe the sensor layout, the beam test setup and the results obtained with both irradiated and non-irradiated prototype devices. …
The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$μ\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order…
Charge collection measurements performed on heavily irradiated p-spray DOFZ pixel sensors with a grazing angle hadron beam provide a sensitive determination of the electric field within the detectors. The data are compared with a complete charge transport simulation of the sensor which includes signal trapping and charge induction effects. A linearly varying electric field based upon the standard picture of a constant type-inverted effective doping density is inconsistent with the data. A two-trap double junction model implemented in the ISE TCAD software can be tuned to produce a doubly-peake…
During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. To upgrade the tracker to required performance level, extensive measurements and simulations studies have already been carried out. A defect model of Synopsys Sentaurus TCAD simulation package for the bulk properties of proton irradiated devices has been producing simulations closely matching wit…
Pixel detectors are used in the innermost part of multi purpose experiments at the Large Hadron Collider (LHC) and are therefore exposed to the highest fluences of ionising radiation, which in this part of the detectors consists mainly of charged pions. The radiation hardness of the detectors has thoroughly been tested up to the fluences expected at the LHC. In case of an LHC upgrade the fluence will be much higher and it is not yet clear up to which radii the present pixel technology can be used. In order to establish such a limit, pixel sensors of the size of one CMS pixel readout chip (PSI4…
The foreseen upgrade of the LHC to its high luminosity phase (HL-LHC), will maximize the physics potential of the facility. The upgrade is expected to increase the instantaneous luminosity by a factor of 5 and deliver an integrated luminosity of 3000 fb-1 after 10 years of operation. As a result of the corresponding increase in radiation and pileup, the electromagnetic calorimetry in the CMS endcaps will sustain maximum integrated doses of 1.5 MGy and neutron fluences above 1e16 neq/cm2, necessitating their replacement for HL-LHC operation. The CMS collaboration has decided to replace the exis…
The ATLAS Forward Physics (AFP) project plans to install 3D silicon pixel detectors about 210 m away from the interaction point and very close to the beamline (2-3 mm). This implies the need of slim edges of about 100-200 $μ$m width for the sensor side facing the beam to minimise the dead area. Another challenge is an expected non-uniform irradiation of the pixel sensors. It is studied if these requirements can be met using slightly-modified FE-I4 3D pixel sensors from the ATLAS Insertable B-Layer production. AFP-compatible slim edges are obtained with a simple diamond-saw cut. Electrical char…
Silicon pixel detectors developed to meet LHC requirements were tested in a beam at CERN in the framework of the ATLAS collaboration. The experimental behaviour of irradiated and not-irradiated sensors in a magnetic field is discussed. The measurement of the Lorentz angle for these sensors at different operating conditions is presented. A simple model of the charge drift in silicon before and after irradiation is presented. The good agreement between the model predictions and the experimental results is shown.
The ATLAS experiment at the LHC will replace its current inner tracker system for the HL-LHC era. 3D silicon pixel sensors are being considered as radiation-hard candidates for the innermost layers of the new fully silicon-based tracking detector. 3D sensors with a small pixel size of $\mathrm{50 \times 50~μm^{2}}$ and $\mathrm{25 \times 100~μm^{2}}$ compatible with the first prototype ASIC for the HL-LHC, the RD53A chip, have been studied in beam tests after uniform irradiation to $\mathrm{5 \times 10^{15}~n_{eq}/cm^{2}}$. An operation voltage of only 50 V is needed to achieve a 97% hit effic…
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator (SOI) technology has already been characterized in terms of radiation hardness to TID (Total Ionizing Dose) and charge collection after a moderate neutron irradiation. In this article we present results of an extensive irradiation hardness study with neutrons up to a fluence of 1x10e16 neq/cm2. Charge collection in a passive pixelated structure was measured by …
HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the $4^{\mathrm{th}}$ generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between $1\cdot 10^{14}$ and $5\cdot 10^{15}$ 1-MeV-n$_\textrm{eq}$/cm$^2$. T…
Temperature dependence of the long-term annealing behavior of neutron irradiated diodes from 8-inch p-type silicon wafers
CERN(欧洲核子研究组织);Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院);Heidelberg University(海德堡大学);Uppsala University(乌普萨拉大学);Al-Farabi Kazakh National University(阿尔法拉比哈萨克国立大学);An Najah National University(安纳贾赫国立大学);HAN University of Applied Sciences(汉应用科学大学)
In view of the LHC upgrade phases towards the High Luminosity LHC (HL-LHC), the ATLAS experiment plans to upgrade the Inner Detector with an all-silicon system. Because of its radiation hardness and cost effectiveness, the n-on-p silicon technology is a promising candidate for a large area pixel detector. The paper reports on the joint development, by LPNHE and FBK of novel n-on-p edgeless planar pixel sensors, making use of the active trench concept for the reduction of the dead area at the periphery of the device. After discussing the sensor technology, a complete overview of the electrical …
A method is proposed for determining the electric field in highly-irradiated silicon pad diodes using admittance-frequency (Y-f ), and current measurements (I). The method is applied to Y-f and I data from square n+p diodes of 25mm2 area irradiated by 24 GeV/c protons to four 1MeV neutron equivalent fluences between 3E15 cm^2 and 13E15 cm^2. The measurement conditions were: Reverse voltages between 1V and 1000V, frequencies between 100Hz and 2MHz and temperatures of -20°C and -30°C. The position dependence of the electric field is parameterised by a linear dependence at the two sides of the di…
Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor tolerance to radiation. At room temperature the large increase in dark count rate makes single photon detection practically impossible already at 10$^{11}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence. The neutron fluences foreseen by many subdetectors to be operated at the high luminosity LHC range up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent. In this paper we presen…
Experiments at the European X-ray Free Electron Laser (XFEL) require silicon pixel sensors which can withstand X-ray doses up to 1 GGy. For the investigation of X-ray radiation damage up to these high doses, MOS capacitors and gate-controlled diodes built on high resistivity n-doped silicon with crystal orientations <100> and <111> produced by two vendors, CiS and Hamamatsu, have been irradiated with 12 keV X-rays at the DESY DORIS III synchrotron light source. Using capacitance/conductance-voltage, current-voltage and thermal dielectric relaxation current measurements, the surface densities o…
The barrel region of the CMS pixel detector will be equipped with ``n-in-n'' type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the pixel area to be less sensitive to particles. In order to quantify this inefficiency prototype pixel sensors irradiated to particle fluences between $4.7\times 10^{13}$ and $2.6\times 10^{15} \Neq$ have been bump bonded to un-irradiated readout chips and tested using high energy pions at the H2 beam line of the CERN SPS. The readout chip allows a non zero s…
Stable Charge Collection and Sub-45 ps Time Resolution in a 4H-SiC PIN Detector Irradiated With Low Fluence 16.5 MeV/u Ta Ions
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Qufu Normal University(曲阜师范大学);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);Liaoning University(辽宁大学)
For the high-luminosity phase of the Large Hadron Collider (HL-LHC), at the expected position of the innermost pixel detector layer of the CMS and ATLAS experiments, the estimated equivalent neutron fluence after 3000 fb$^{-1}$ is 2$\cdot$10$^{16}$ n$_{eq}$/cm$^2$, and the IEL (Ionizing Energy Loss) dose in the SiO$_2$ 12 MGy. The optimisation of the pixel sensors and the understanding of their performance as a function of fluence and dose makes a radiation damage model for TCAD simulations, which describes the available experimental data, highly desirable. The currently available bulk-damage …
The current understanding of radiation tollerance of Silicon Photomultipliers (SiPMs) is reviewd. Radiation damage in silicon sensors is briefly introduced, surface and bulk effects are separately addressed. Results on the operation of irradiated SiPMs with X-ray, gamma, electron, proton and neutron sources are presented. The most critical effect of radiation on SiPMs is the increase of dark count rate, which makes it impossible to resolve signals generated by a single photon from the noise. Methods to characterize irradiated SiPMs after their single photo-electron resolution is lost are discu…
Thin pad detectors made from 75 $μ$m thick epitaxial silicon on low resistivity substrate were irradiated with reactor neutrons to fluences from 2.5$\times 10^{16}$ n/cm$^2$ to 1$\times 10^{17}$ n/cm$^2$. Edge-TCT measurements showed that the active detector thickness is limited to the epitaxial layer and does not extend into the low resistivity substrate even after the highest fluence. Detector current was measured under reverse and forward bias. The forward current was higher than the reverse at the same voltage but the difference gets smaller with increasing fluence. Rapid increase of curre…
A new module concept for future ATLAS pixel detector upgrades is presented, where thin n-in-p silicon sensors are connected to the front-end chip exploiting the novel Solid Liquid Interdiffusion technique (SLID) and the signals are read out via Inter Chip Vias (ICV) etched through the front-end. This should serve as a proof of principle for future four-side buttable pixel assemblies for the ATLAS upgrades, without the cantilever presently needed in the chip for the wire bonding. The SLID interconnection, developed by the Fraunhofer EMFT, is a possible alternative to the standard bump-bonding. …
Bare reverse biased silicon photodiodes were exposed to 3eV He+, Ne+, Ar+, N2+, N+ and H2O+ ions. In all cases an increase of the reverse current through the diode was observed. This effect and its dependence on the ionization energy of the incident ions and on other factors are qualitatively explained in the framework of Auger-type surface neutralization theory. Amplification of the ion-induced charge was observed with an avalanche photodiode under high applied bias. The observed effect can be considered as ion-induced internal potential electron emission into the conduction band of silicon. …
CVD diamond is an attractive material option for LHC vertex detectors because of its strong radiation-hardness causal to its large band gap and strong lattice. In particular, pixel detectors operating close to the interaction point profit from tiny leakage currents and small pixel capacitances of diamond resulting in low noise figures when compared to silicon. On the other hand, the charge signal from traversing high energy particles is smaller in diamond than in silicon by a factor of about 2.2. Therefore, a quantitative determination of the signal-to-noise ratio (S/N) of diamond in compariso…