190 Pt α衰变half-life的一种新的精密测量方法

A new precision measurement of the α-decay half-life of 190Pt

Miháy Braun, Yordan M. Georgiev, Tommy Schönherr, Heinrich Wilsenach, Kai Zuber

摘要:

使用低背景弗里希栅格电离室对$^{190}$ Pt的$α$ -衰变半衰期进行了实验室测量。在75.9天的时间里,已经测量了总量为216.60(17)mg的天然铂。由此得出的半衰期为$(4.97\pm0.16)\times 10^{11}$年,总不确定度为3.2%。这一数字与使用地质比较法获得的半衰期非常一致。

英文摘要:

A laboratory measurement of the $α$-decay half-life of $^{190}$Pt has been performed using a low background Frisch grid ionisation chamber. A total amount of 216.60(17) mg of natural platinum has been measured for 75.9 days. The resulting half-life is $(4.97\pm0.16)\times 10^{11}$ years, with a total uncertainty of 3.2%. This number is in good agreement with the half-life obtained using the geological comparison method.