First application of combined isochronous and Schottky mass spectrometry: Half-lives of fully ionized 49Cr24+ and 53Fe26+ atoms
X. L. Tu, X. C. Chen, J. T. Zhang, P. Shuai, K. Yue, X. Xu, C. Y. Fu, Q. Zeng, X. Zhou, Y. M. Xing, J. X. Wu, R. S. Mao, L. J. Mao, K. H. Fang, Z. Y. Sun, M. Wa… 展开作者
X. L. Tu, X. C. Chen, J. T. Zhang, P. Shuai, K. Yue, X. Xu, C. Y. Fu, Q. Zeng, X. Zhou, Y. M. Xing, J. X. Wu, R. S. Mao, L. J. Mao, K. H. Fang, Z. Y. Sun, M. Wang, J. C. Yang, Yu. A. Litvinov, K. Blaum, Y. H. Zhang, Y. J. Yuan, X. W. Ma, X. H. Zhou, H. S. Xu
用等熵肖特基质谱法测量了储存环CSRe中b衰变高电荷态离子的寿命。在58 Ni原束的射弹碎裂过程中产生了完全电离的49 Cr和53 Fe离子,并将其存储在调谐到等离子光学模式的CSRe中。利用这种新型的共振肖特基探测器对49 Cr24+和53 Fe 26+离子的存储强度进行了测量。提取半衰期T1/2(49 Cr 24+)= 44.0(27)min和T1/2(53 Fe 26+)= 8.47(19)min与针对禁用电子捕获分支校正的文献半衰期值非常一致。这是实现在未来储存环设施上同时测量奇异核的质量和寿命的重要的原理验证步骤。
英文摘要:
Lifetime measurements of b -decaying highly charged ions have been performed in the storage ring CSRe by applying the isochronous Schottky mass spectrometry. The fully ionized 49Cr and 53Fe ions were produced in projectile fragmentation of 58Ni primary beam and were stored in the CSRe tuned into the isochronous ion-optical mode. The new resonant Schottky detector was applied to monitor the intensities of stored uncooled 49Cr24+ and 53Fe26+ ions. The extracted half-lives T1/2(49Cr24+) = 44.0(27) min and T1/2(53Fe26+) = 8.47(19) min are in excellent agreement with the literature half-life values corrected for the disabled electron capture branchings. This is an important proof-of-principle step towards realizing the simultaneous mass and lifetime measurements on exotic nuclei at the future storage ring facilities.
Charge resolution in the isochronous mass spectrometry and the mass of $^{51}$Co
重离子储存环等离子体质谱(IMS)是测量短寿命核质量的有力工具。在IMS实验中,通过精确测量储存在环中的离子的旋转时间来确定质量。然而,对于具有几乎相同的质荷比(m/q)的粒子,无法解析旋转时间。为了克服这一限制并提取m/q比非常接近的离子种类对的准确旋转时间,在我们早期的粒子识别工作中,我们分析了基于发射的检测器的定时信号的幅度。次级电子。这里,通过考虑信号幅度、检测效率和环中存储的离子的数量,进一步改进了先前的数据分析方法。在数据分析中引入了一个敏感的Z依赖性参数,导致$^{34}$ Ar $^{18+}$和$^{51}$ Co $^{27+}$的更好分辨率,A/Z=17/9。虽然$^{34}$ Ar $^{18+}$和$^{51}$ Co $^{27+}$的时间差仅为1.8 ps,但它们的平均公转时间却被推导出来。这些离子的未校正的重叠峰具有7.7ps的半峰全宽。$^{51}$ Co的质量过剩被确定为-27332(41)keV,这与先前的值-27342(48)keV一致。
Charge and frequency resolved isochronous mass spectrometry in storage rings: First direct mass measurement of the short-lived neutron-deficient $^{51}$Co nuclide
储存环中单个离子的旋转频率测量需要复杂的定时探测器。用于这种检测器的常见方法之一是检测由于所存储的离子的穿透而从薄箔释放的次级电子。提出了一种基于次级电子强度分析的新方法,该方法可以在测量离子旋转频率的同时确定离子的电荷。虽然$^{51}$ Co $^{27+}$和$^{34}$ Ar $^{18+}$离子的质荷比几乎相同,因而不能在储存环中分辨,但应用新方法首次确定了短寿命$^{51}$ Co的质量过剩为ME($^{51}$ Co)=-27342(48)keV.壳模型计算的$fp$壳核相比,新的数据表明,需要包括同位旋非守恒力。