An improvement of isochronous mass spectrometry: Velocity measurements using two time-of-flight detectors
P. Shuai, X. Xu, Y. H. Zhang, H. S. Xu, Yu. A. Litvinov, M. Wang, X. L. Tu, K. Blaum, X. H. Zhou, Y. J. Yuan, X. L. Yan, X. C. Chen, R. J. Chen, C. Y. Fu, Z. Ge… 展开作者
P. Shuai, X. Xu, Y. H. Zhang, H. S. Xu, Yu. A. Litvinov, M. Wang, X. L. Tu, K. Blaum, X. H. Zhou, Y. J. Yuan, X. L. Yan, X. C. Chen, R. J. Chen, C. Y. Fu, Z. Ge, W. J. Huang, Y. M. Xing, Q. Zeng
备注:
Accepted by Nuclear Inst. and Methods in Physics Research, B
Isochronous mass spectrometry (IMS) in storage rings is a powerful tool for mass measurements of exotic nuclei with very short half-lives down to several tens of microseconds, using a multicomponent secondary beam separated in-flight without cooling. However, the inevitable momentum spread of secondary ions limits the precision of nuclear masses determined by using IMS. Therefore, the momentum measurement in addition to the revolution period of stored ions is crucial to reduce the influence of the momentum spread on the standard deviation of the revolution period, which would lead to a much improved mass resolving power of IMS. One of the proposals to upgrade IMS is that the velocity of secondary ions could be directly measured by using two time-of-flight (double TOF) detectors installed in a straight section of a storage ring. In this paper, we outline the principle of IMS with double TOF detectors and the method to correct the momentum spread of stored ions.
Accurately accounting for effects on times-of-flight caused by finite field-transition times during the ejection of ions from a storage trap: A study for TOF and MRTOF mass spectrometry
Accurate Reporting of Ion Time-of-Flight during HiPIMS with Gated Front-End Mass Spectrometry
Laboratory for Surface Science and Coating Technologies, Empa − Swiss Federal Laboratories for Materials Science and Technology(表面科学与涂层技术实验室,瑞士联邦材料科技研究院)
The TRAPSENSOR Facility: an Open-Ring 7-Tesla Penning Trap for Laser-Based Precision Experiments
Penning阱电子探测技术提供了质谱法所要求的精确度和灵敏度,用于核物理和粒子物理的基础研究,但尚未被证明是通用的。这激发了Penning阱设备的构建,其旨在实现一种新的检测方法,包括通过来自$^{40}$ Ca $^+$中的4s $^2$ S $_{1/2}\rightarrow $ 4 p $^2$ P $_{1/2}$原子跃迁的荧光光子来测量强磁场中单电荷捕获离子的运动频率。该设施的关键要素是一个已建成并已充分表征的开环潘宁阱,该阱在上游与一个与放射性离子束设施所建阱相似的制备潘宁阱相连。运动频率测量存储在开环阱中的被困离子已进行了应用外部偶极和四极场共振与离子的本征运动,结合飞行时间识别。观察$^{40}$ Ca $^+$荧光光子的基础设施,包括7特斯拉所需的12束激光束,以及在高灵敏度CCD传感器中记录图像的2米长的系统,也已通过光学观察捕获的$^{40}$ Ca $^+$离子成功地进行了测试。这证明了该设施的能力,拟议的基于激光的质谱技术,并介绍了它作为一个独特的平台,以执行激光光谱实验,在不同的物理领域的影响。
ToF-PAX-RIXS: A Time-of-Flight Spectrometer for combined ARPES and RIXS
Karlsruhe Institute of Technology(卡尔斯鲁厄理工学院);Johannes Gutenberg-Universität(约翰内斯·古腾堡大学);Deutsches Elektronen-Synchrotron DESY(德国电子同步加速器);Stockholm University(斯德哥尔摩大学);Christian-Albrechts-Universität zu Kiel(基尔大学)