用于理化学研究所稀有放射性同位素环质量测量的大面积时序与位置灵敏箔片-微通道板探测器的研制

Development of a large-area timing and position-sensitive foil-MCP detector for mass measurements at the Rare-RI Ring in RIKEN

Zhuang Ge

AI总结:

本研究为RIKEN稀有放射性同位素环的TOF质量测量研制了大面积箔片-MCP位置灵敏静电探测器,通过探测二次电子实现测量,经优化后获得了优异的时序、位置分辨率及探测效率,可兼顾束流监测等用途。

摘要:

为通过飞行时间(TOF)方法——高分辨率束流线磁刚度飞行时间(B$ρ$-TOF)和环内等时性质谱(IMS)——实现对奇特原子核质量测量的高精度与高准确度,日本理化学研究所仁科中心放射性同位素束工厂(RIBF)的稀有放射性同位素环(Rare-RI Ring)研制了一款同时具备高位置分辨率和良好时序分辨率的大面积静电探测器。除TOF质量测量外,该探测器系统还将用于稀有放射性同位素环的束流线与环内的重离子束轨迹监测或动量测量。\n重离子的位置与时序测量通过探测离子穿过转换箔片时发射的二次电子(SEs)来实现。二次电子经静电场加速并以$90^{\text{o}}$角偏转到与位置灵敏延迟线阳极耦合的微通道板(MCP)电子倍增器上。研究人员通过模拟与实验系统研究了时序和位置分辨率对探测器电位板所加高压的依赖关系,并选取探测器静电场中二次电子传输的等时条件来优化探测器结构,以实现高性能。\n目前取得的最佳性能为:时序分辨率优于50 ps(以$σ$计),二维位置分辨率约1 mm(以$σ$计)。对重离子束的整体效率约为95$\text{%}$,对$^{241}$Am源产生的$α$粒子的整体效率约为75$\text{%}$。

英文摘要:

To achieve high precision and accuracy for mass measurements of exotic nuclei by Time-of-flight (TOF) methods: high-resolution beam-line magnetic-rigidity time-of-flight (B$ρ$-TOF) and in-ring isochronous mass spectrometry (IMS), a large-area electrostatic detector which possesses high position resolution and good timing resolution at the same time is developed at the Rare-RI Ring in RIBF, RIKEN Nishina Center, Japan. Besides TOF mass measurements, the detector system will also be used for heavy ion beam trajectory monitoring or momentum measurements for both beam-line and in-ring at the Rare-RI Ring. The position and timing measurements of heavy ions are performed by detecting the secondary electrons (SEs) emitted from a conversion foil during the passage of the ion. The SEs are accelerated and bent with an angle of $90^{\circ}$ by electrostatic fields onto a micro-channel-plate (MCP) electron multiplier which is coupled with a position-sensitive delay-line anode. The dependence of the timing and position resolution on applied high voltages of the detector potential plates has been studied systematically via simulation and experimentally. An isochronous condition of secondary electron transmission in the electrostatic field of the detector is chosen to optimize the structure of the detector for high performance. The best achieved timing resolution is less than 50 ps (in $σ$) and position resolution $\sim$ 1 mm (in $σ$) for 2 dimensions, respectively. The overall efficiency is $\sim$ 95$\%$ for heavy ion beam and $\sim$ 75$\%$ for $α$ particle from $^{241}$Am source.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑