摘要:
使用超低本底双弗里希栅电离室(TF-GIC)对$^{147}$ Sm的α衰变进行了研究。在超高真空中用脉冲激光沉积法制备了四种天然钐样品。用电感耦合等离子体质谱法测定了$^{147}$ Sm同位素的丰度。测量了147 Sm的联合半衰期值为$1.079(26)\times{}10^{11}$年。使用$γ$光谱法对$^{143}$ Nd的第一激发态的α衰变进行了研究,得到了$T_{1/2} > 3.1 \times{}10^{18}$年的半衰期下限(90% C. L.)。
英文摘要:
An investigation of the α-decay of $^{147}$Sm was performed using an ultra low-background Twin Frisch-Grid Ionisation Chamber (TF-GIC). Four natural samarium samples were produced using pulsed laser deposition in ultra high vacuum. The abundance of the $^{147}$Sm isotope was mea- sured using inductively coupled plasma mass spectrometry. A combined half-life value for 147Sm of $1.079(26)\times{}10^{11}$ years was measured. A search for the α-decay into the first excited state of $^{143}$Nd has been performed using $γ$-spectroscopy, resulting in a lower half-life limit of $T_{1/2} > 3.1 \times{}10^{18}$ years (at 90% C.L.).