基于时间非局部均值方法的四维锥束CT重建与增强

Four-dimensional Cone Beam CT Reconstruction and Enhancement using a Temporal Non-Local Means Method

Xun Jia, Zhen Tian, Yifei Lou, Jan-Jakob Sonke, Steve B. Jiang

摘要:

四维锥形束计算机断层成像(4D-CBCT)已开发用于在图像引导放射治疗(IGRT)中提供呼吸相位分辨体积成像。每个相位箱中的投影数量不足导致低质量的4D-CBCT图像具有明显的条纹伪影。在这项工作中,我们提出了两个新的4D-CBCT算法:迭代重建算法和增强算法,利用时间非局部均值(TNLM)方法。我们为给定的4D-CBCT图像集定义TNLM能量项。该项的最小化有利于那些4D-CBCT图像,使得在一个相位的一个空间点处的任何解剖特征可以在相邻相位的附近空间点中找到。通过最小化包含数据保真度项和TNLM能量项的总能量来实现4D-CBCT重建。对于图像增强,通过最小化TNLM函数来增强由FDK算法生成的4D-CBCT图像,同时保持增强图像接近FDK结果。采用前向-后向分裂算法和高斯-雅可比迭代法求解该问题。该算法在GPU上实现,以实现较高的计算效率。重建算法和增强算法生成视觉上相似的4D-CBCT图像,均优于FDK结果。定量评价表明,与FDK结果相比,该重建方法的对比度噪声比(CNR)提高了2.56~3.13倍,增强方法的CNR提高了2.75~3.33倍。该增强方法还从FDK结果中去除了超过80%的条纹伪影。在NVIDIA Tesla C1060 GPU卡上,重建算法的总计算时间约为460秒,增强算法的总计算时间约为610秒。

英文摘要:

Four-dimensional Cone Beam Computed Tomography (4D-CBCT) has been developed to provide respiratory phase resolved volumetric imaging in image guided radiation therapy (IGRT). Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. In this work, we propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. We define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms are implemented on GPU to achieve a high computational efficiency. The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56~3.13 and our enhancement method increases the CNR by 2.75~3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is ~460 sec for the reconstruction algorithm and ~610 sec for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑