Intercomparison of Monte Carlo calculated dose enhancement ratios for gold nanoparticles irradiated by X-rays: assessing the uncertainty and correct methodology for extended beams
H. Rabus, W. B. Li, C. Villagrasa, J. Schuemann, P. A. Hepperle, L. de la Fuente Rosales, M. Beuve, S. Di Maria, A. P. Klapproth, C. Y. Li, F. Poignant, B. Rudek, H. Nettelbeck
Results of a Monte Carlo code intercomparison exercise for simulations of the dose enhancement from a gold nanoparticle (GNP) irradiated by X-rays have been recently reported. To highlight potential differences between codes, the dose enhancement ratios (DERs) were shown for the narrow-beam geometry used in the simulations, which leads to values significantly higher than unity over distances in the order of several tens of micrometers from the GNP surface. As it has come to our attention that the figures in our paper have given rise to misinterpretation as showing 'the' DERs of GNPs under diagnostic X-ray irradiation, this article presents estimates of the DERs that would have been obtained with realistic radiation field extensions and presence of secondary particle equilibrium (SPE). These DER values are much smaller than those for a narrow-beam irradiation shown in our paper, and significant dose enhancement is only found within a few hundred nanometers around the GNP. The approach used to obtain these estimates required the development of a methodology to identify and, where possible, correct results from simulations whose implementation deviated from the initial exercise definition. Based on this methodology, literature on Monte Carlo simulated DERs has been critically assessed.
An intercomparison exercise is described that examines Monte Carlo modelling of anthropomorphic voxel phantoms in an idealized ground-contamination photon exposure scenario. Thirteen participants calculated and submitted organ and effective dose rates for comparison against a set of verified reference solutions. The effective dose rates are shown to agree with the reference value to within reasonable statistical uncertainties in five of the cases, though in only one of those was similar agreement also demonstrated in the evaluation of all requested organ dose rates. Orders-of-magnitude differe…
Organized by the European Radiation Dosimetry Group (EURADOS), a Monte Carlo code intercomparison exercise was conducted where participants simulated the emitted electron spectra and energy deposition around a single gold nanoparticle (GNP) irradiated by X-rays. In the exercise, the participants scored energy imparted in concentric spherical shells around a spherical volume filled with gold or water as well as the spectral distribution of electrons leaving the GNP. Initially, only the ratio of energy deposition with and without GNP was to be reported. During the evaluation of the exercise, how…
Carbon ion is the mostly common used particle in heavy ion radiotherapy. In this paper, carbon ion dose in tumor treatment for human eye was simulated with FLUKA code, 80 MeV/u carbon beam was irradiated into the human eye from two directions, The first is from the lateral-forward direction which was a typical therapeutic condition, maximum dose was deposited in the tumor volume. The second one was that beam irradiated into eyes from the forward direction which may cause certain medical accident. The calculated results are compared with other reports. The agreement indicates that this method c…
Ion chamber dosimetry is being used to calibrate dose for cell irradiations designed to investigate photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. This study performed a dosimetry intercomparison for synchrotron-produced monochromatic x-ray beams at 25 and 35 keV. Ion chamber depth-dose measurements in a PMMA phantom were compared with the product of MCNP5 Monte Carlo calculations of dose per fluence and measured incident fluence. Monochromatic beams of 25 and 35 keV were generated on the tomography beamline at CAMD. A cylindrical, air-equiva…
Laser-accelerated protons have a great potential for innovative experiments in radiation biology due to the sub-picosecond pulse duration and high dose rate achievable. However, the broad angular divergence makes them not optimal for applications with stringent requirements on dose homogeneity and total flux at the irradiated target. The strategy otherwise adopted to increase the homogeneity is to increase the distance between the source and the irradiation plane or to spread the beam with flat scattering systems or through the transport system itself. Such methods considerably reduce the prot…
We study the propagation of nucleons and nuclei in tissue-like media within a Monte Carlo Model for Heavy-ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.2). The model takes into account fragmentation of projectile nuclei and secondary interactions of produced nuclear fragments. Model predictions are validated with available experimental data obtained for water and PMMA phantoms irradiated by monoenergetic carbon-ion beams. The MCHIT model describes well (1) the depth-dose distributions in water and PMMA, (2) the doses measured for fragments of certain charge, (3) the distributions …
We propose a methodology to perform dose measurements using gafchromic films which can span several decades of dose levels. The technique is based on a rescaling approach using different films irradiated at different dose levels. This is combined with a registration protocol correcting positioning and scaling factors for each film.
The application of metal nanoparticles as sensitization materials is a common strategy that is used to study dose enhancement in radiotherapy. Recent in vitro tests have revealed that magnetic gold nanoparticles can be used in cancer therapy under a magnetic field to enhance the synergistic efficiency in radiotherapy and photothermal therapy. However, magnetic gold nanoparticles have rarely been studied as sensitization materials. In this study, we obtained further results of the sensitization properties of magnetic gold nanoparticles using the Monte Carlo method TOPAS and TOPAS-nBio. We analy…
We have developed a novel in-vivo dosimeter based on glass encapsulated TLD rods. These encapsulated rods can be injected into mice and used for validating doses to an individual mouse in a protracted irradiation scenario where the mouse is free to move in an inhomogenous radiation field. Data from 30 irradiated mice shows a reliable dose reconstruction within 10% of the nominal delivered dose.
With increasing patient and staff X-ray radiation awareness, many efforts have been made to develop accurate patient dose estimation methods. To date, Monte Carlo (MC) simulations are considered golden standard to simulate the interaction of X-ray radiation with matter. However, sensitivity of MC simulation results to variations in the experimental or clinical setup of image guided interventional procedures are only limited studied. In particular, the impact of patient material compositions is poorly investigated. This is mainly due to the fact, that these methods are commonly validated in pha…
The SHIELD-HIT transport code, in several versions, has been used for modeling the interaction of therapeutic beams of light nuclei with tissue-equivalent materials for a long time. All versions of the code include useful option of decomposition of the absorbed dose by the linear energy transfer (LET), but this option has not been described and published so far. In this work the procedure of decomposition of the absorbed dose by LET is described and illustrated by using the decomposition of the Bragg curve in water phantom, irradiated by beams of protons, alpha particles, and of ions lithium, …
This work investigates the dose-response curves of GAFCHROMIC EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University CAMD synchrotron facility. Monochromatic beams of 25, 30, and 35 keV were generated on the tomography beamline at CAMD. Ion chamber depth-dose measurements were used to determine the dose delivered to films irradiated at depths from 0.7 to 8.5 cm in a 10x10x10-cm3 PMMA phantom. AAPM TG-61 protocol was applied to conver…
Purpose: The purpose of this work is to develop a new approach for high spatial resolution dosimetry based on Raman micro-spectroscopy scanning of radiochromic film (RCF). We generate dose calibration curves over an extended dose range from 0-50 Gy and with improved sensitivity to low (<2 Gy) doses, in addition to evaluating uncertainties. Methods: Samples of RCF (EBT3) were irradiated at a broad dose-range of 0.03 Gy-50 Gy. Raman spectra were acquired with a custom-built Raman micro-spectroscopy setup involving a 500 mW, multimode 785 nm laser. The depth of focus of 34 um enabled the concurre…
Carbon ion therapy have the ability to overcome the limitation of convertional radiotherapy due to its most energy deposition in selective depth, usually called Bragg peak, which results in increased biological effectiness. During carbon ion therapy, lots positron emitters such as $^{11}$C, $^{15}$O, $^{10}$C are generated in irradiated tissues by nuclear reactions. Immediately after patient irradiation, PET scanners can be used to measure the spatial distribution of positron emitters, which can track the carbon beam to the tissue. In this study, we designed and evaluated an dual-plate in-room…
This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of parti…
The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle(GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy sources. Dose distribution in the tumor and healthy tissues have been taken into account for both mentioned brachytherapy sources. Also, in a certain point of the eye, the ratio of the absorbed dose by t…
Hadrontherapy is an emerging technique in cancer therapy that uses beams of charged particles. To meet the improved capability of hadrontherapy in matching the dose release with the cancer position, new dose monitoring techniques need to be developed and introduced into clinical use. The measurement of the fluxes of the secondary particles produced by the hadron beam is of fundamental importance in the design of any dose monitoring device and is eagerly needed to tune Monte Carlo simulations. We report the measurements done with charged secondary particles produced from the interaction of a 80…
We have used an inexpensive 3D printer mounting an inexpensive pre-irradiated silicon diode to measure the 2D dose distribution of a small (approximately 10mm FWHM) proton beam. z was measured with high resolution whereas x was changed on a 2mm grid for a total of 12 scans and 2 repeats in 20 minutes. The peak dose to the diode was approximately 530 cGy/s, and no degradation in diode sensitivity was observed. We present beam profiles and a 2D beam contour derived from these data. Most of the scan time was spent changing x by hand, and a more appropriate 3D printer along with an improved setup …