This paper describes the dose delivery system used at the Centro Nazionale di Adroterapia Oncologica (CNAO) for ion beam modulated scanning radiotherapy. CNAO Foundation, INFN and University of Torino have developed and commissioned a Dose Delivery System (DDS) to monitor and guide ion beams accelerated by a synchrotron and to distribute the dose with a 3D scanning technique. The target volume, segmented in several layers orthogonally to the beam direction, is irradiated by thousands of pencil beams which must be steered and held to the prescribed positions until the prescribed number of particles has been delivered. At CNAO, these operations are performed by the DDS. The main components of this system are 2 independent beam monitoring detectors (BOX1 and BOX2), interfaced with 2 control systems performing real-time control, and connected to the scanning magnets and the beam chopper. As a reaction to any potential hazard, a DDS interlock signal is sent to the Patient Interlock System which immediately stops the irradiation. The tasks and operations performed by the DDS are described following the data flow from the Treatment Planning System through the end of the treatment delivery. The ability of the DDS to guarantee a safe and accurate treatment was validated during the commissioning phase by means of checks of the charge collection efficiency, gain uniformity of the chambers and 2D dose distribution homogeneity and stability. A high level of reliability and robustness has been proven by 3 years of system activity. The DDS described in this paper is one among the few worldwide existing systems to operate ion beam for modulated scanning radiotherapy. It has proven to guide and control the therapeutic pencil beams with accuracy and stability showing dose deviations lower than the acceptance threshold of 5% and 2.5% respectively during daily Quality Assurance measurements.
In radiotherapy, a trade-off exists between computational workload/speed and dose calculation accuracy. Calculation methods like pencil-beam convolution can be much faster than Monte-Carlo methods, but less accurate. The dose difference, mostly caused by inhomogeneities and electronic disequilibrium, is highly correlated with the dose distribution and the underlying anatomical tissue density. We hypothesize that a conversion scheme can be established to boost low-accuracy doses to high-accuracy, using intensity information obtained from computed tomography (CT) images. A deep learning-driven f…
Dose painting has been developed to modulate the required dose in the target area without increasing the toxicity in healthy areas. Apart from determining the accurate location and size of tumors, quantitative functional imaging can be used to implement the dose painting. Functional imaging, such as multi-parameter MRI and PET CT, allows us to achieve biological dose escalation by increasing the dose in certain areas or voxels that are therapy-resistant in the gross tumor volume while reducing the dose in the less aggressive area or voxels. Functional imaging can serve as an indicator of thera…
Voxel-Based Conversion of Hypofractionated Radiotherapy Dose Distributions to 2 Gy-Equivalent OAR Constraints: Proof-of-Concept Demonstrating the Radiobiological Benefits of Hypofractionation in a Prostate Radiotherapy Case
Healthy Innovations;Holy Family University(圣家大学);Tripoli Governmental Hospital and Doctors Center(的黎波里政府医院和医生中心)
In carbon-ion radiotherapy, single-beam delivery each day in alternate directions has been commonly practiced for operational efficiency, taking advantage of the Bragg peak and the relative biological effectiveness (RBE) for uniform dose conformation to a tumor. The treatment plans are usually evaluated with total RBE-weighted dose, which is however deficient in relevance to the biological effect in the linear-quadratic model due to its quadratic-dose term, or the dose-fractionation effect. In this study, we reformulate the extrapolated response dose (ERD), or synonymously BED, which normalize…
Purpose: Various dose calculation algorithms are available for radiation therapy for cancer patients. However, these algorithms are faced with the tradeoff between efficiency and accuracy. The fast algorithms are generally less accurate, while the accurate dose engines are often time consuming. In this work, we try to resolve this dilemma by exploring deep learning (DL) for dose calculation. Methods: We developed a new radiotherapy dose calculation engine based on a modified Hierarchically Densely Connected U-net (HD U-net) model and tested its feasibility with prostate intensity-modulated rad…
To enable magnetic resonance (MR)-only radiotherapy and facilitate modelling of radiation attenuation in humans, synthetic-CT (sCT) images need to be generated. Considering the application of MR-guided radiotherapy and online adaptive replanning, sCT generation should occur within minutes. This work aims at assessing whether an existing deep learning network can rapidly generate sCT images to be used for accurate MR-based dose calculations in the entire pelvis. A study was conducted on data of 91 patients with prostate, rectal and cervical cancer who underwent external beam radiotherapy acquir…
Ultra high dose rate electron beams also known as FLASH radiotherapy is becoming of importance in several preclinial cancer treatment studies. However, due to the dose rate used during the irradiation sessions, no real time dose monitoring device exists to date. In this work, we present the development of a beam current transformer (BCT), from the choice of the ferromagnetic component and the realisation of the shielding to the design of a front-end electronics based on a trans-impedance circuit in order to perform a low noise optimization of the detector. The BCT prototype is able to monitor …
Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of tr…
Purpose: Variations in proton Relative Biological Effectiveness (RBE) with Linear Energy Transfer (LET) remain one of the largest sources of uncertainty in proton radiotherapy. This work seeks to identify physics-based metrics which can be applied to reduce this biological uncertainty. Materials and Methods: Three different physical metrics - dose, dose $\times$ LET and a complexity-weighted dose (CWD, Dose $\times$ (1+$κLET_D$) ) were compared with in vitro experimental studies of proton RBE and clinical treatment plans analysed using RBE models. The biological effects of protons in each syst…
It has long been known that radiation biology plays an important role and it is necessary for radiotherapy treatments. The radiation effects on normal and malignant tissues after exposure range from a femtosecond to months and years thereafter [1,2]. Therefore, to optimize treatment, it is crucial to explain and understand these mechanisms [3-5]. Providing a conceptual basis for radiotherapy and identifying the mechanisms and processes that underlie the tumor and normal tissue responses to irradiation can help to explain the observed phenomena [6]. Examples include understanding hypoxia, reoxy…
Automating the radiotherapy treatment planning process is a technically challenging problem. The majority of automated approaches have focused on customizing and inferring dose volume objectives to used in plan optimization. In this work we outline a multi-patient atlas-based dose prediction approach that learns to predict the dose-per-voxel for a novel patient directly from the computed tomography (CT) planning scan without the requirement of specifying any objectives. Our method learns to automatically select the most effective atlases for a novel patient, and then map the dose from those at…
The RefleXion X1 is the first biology-guided radiotherapy (BgRT) system. Its dual 90-degree PET detector collects fewer pair production events compared to a full-ring diagnostic PET system. In the proposed BgRT workflow, a short scan is acquired before treatment delivery to ensure image quality and consistency. The shorter scan time, a quarter of the simulation scan time, also leads to fewer coincidence events and hence reduced image quality. In this study, we proposed a patient-specific mean teacher UNet (MT-UNet) to enhance PET image quality and low-dose PET reconstruction on RefleXion X1. P…
The next great leap toward improving treatment of cancer with radiation will require the combined use of online adaptive and magnetic resonance guided radiation therapy techniques with automatic X-ray beam orientation selection. Unfortunately, by uniting these advancements, we are met with a substantial expansion in the required dose information and consequential increase to the overall computational time imposed during radiation treatment planning, which cannot be handled by existing techniques for accelerating Monte Carlo dose calculation. We propose a deep convolutional neural network appro…
The aim of this study is to investigate the dose-deposition enhancement by alpha-particle irradiation in a cellular model using carbon and oxygen chemical compositions.A simulation study was performed to study dose enhancement due to carbon and oxygen for a human cell where Geant4 code used for the alpha-particle irradiation to the cellular phantom. The characteristic of dose enhancement in the nucleus and cytoplasm by the alpha-particle radiation was investigated based on concentrations of the carbon and oxygen compositions and was compared with those by gold and gadolinium.The results show t…
Dose painting of hypoxic tumour sub-volumes using positron-emission tomography (PET) has been shown to improve tumour control in silico in several sites. Pancreatic cancer presents a more stringent challenge, given its proximity to critical organs-at-risk (OARs) and anatomic motion. A radiobiological model was developed to estimate clonogen survival fraction (SF), using 18F-fluoroazomycin arabinoside PET (FAZA PET) images from ten patients with pancreatic cancer to quantify oxygen enhancement effects. For each patient, four simulated five-fraction stereotactic body radiotherapy (SBRT) plans we…
Background and purpose: To investigate the possible contribution of indirect damage and damage saturation to tumour control obtained with SBRT/SRS treatments for early-stage NSCLC and brain metastases. Methods and Materials: We have constructed a dataset of early-stage NSCLC and brain metastases dose-response. These data were fitted to models based on the linear-quadratic (LQ), the linear-quadratic-linear (LQL), and phenomenological modifications of the LQ-model to account for indirect cell damage. We use the Akaike-Information-Criterion formalism to compare performance, and studied the stabil…
\item[Purpose] A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45\%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. \item[Methods] Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles, for each of which the dose and the relative biological effectiveness (RBE) were estimated at a tumor depth in the middle of spread-out Bragg peak. Assuming exponential behavior for atte…
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose esti…
Toward CT-Equivalent Image Quality in Low-Dose Radiotherapy Planning: Conditional Diffusion-Based CBCT-to-CT Synthesis and the Impact of CBCT Input Representation
Jordan University of Science and Technology(约旦科技大学);University of Dundee(邓迪大学);NHS Ninewells Dundee(NHS邓迪奈恩韦尔斯医院);University of Glasgow(格拉斯哥大学)
Cancer is a primary cause of morbidity and mortality worldwide. The radiotherapy plays a more and more important role in cancer treatment. In the radiotherapy, the dose distribution maps in patient need to be calculated and evaluated for the purpose of killing tumor and protecting healthy tissue. Monte Carlo (MC) radiation transport calculation is able to account for all aspects of radiological physics within 3D heterogeneous media such as the human body and generate the dose distribution maps accurately. However, an MC calculation for doses in radiotherapy usually takes a great mass of time t…
Purpose: The purpose of the present article is to propose a modified version of the D-shaped collimator used at the Univ. Hosp. of Essen for retinoblastoma treatment that reduces even further the irradiation field with the scope to reduce the risk of radio-induced secondary malignancies. The new dedicated D-shaped collimator is easier to build and produces dose distributions that only differ on the field size with respect to the dose distributions obtained by the current collimator in use. Methods: The Monte Carlo code PENELOPE was used to study the effect that the structural elements of the c…
This research considers potential dose increase in target due to cisplatin (Pt) concentration and radiation type. Cisplatin concentrations from 0.003 to 120 mM were used. Monte-Carlo simulation of Linear accelerator (Elekta Synergy) and X-ray tube (Xstrahl300) was carried out using Geant4 and PClab. As the first step of this research, we performed simulation of energy spectrum from radiotherapy units (spectrum model). The next step was the modeling of linear accelerator head and X-ray tube, and the distribution of dose in the water phantom (PDD model). At the second stage, dose changes were in…
Purpose: To investigate the validity of two Monte Carlo simulation absolute dosimetry approaches in the case of a small field dedicated `D'-shaped collimator used for the retinoblastoma treatment with external photon beam radiotherapy. Methods: The Monte Carlo code {\sc penelope} is used to simulate the linac, the dedicated collimator and a water phantom. The absolute doses (in Gy per monitor unit) for the field sizes considered are obtained within the approach of Popescu {\it et al.} in which the tallied backscattered dose in the monitor chamber is accounted for. The results are compared to e…
With the continued evolution of modern radiation therapy towards high precision delivery of high therapeutic doses to the tumour while optimally sparing surrounding healthy tissue, imaging becomes a crucial component to identify the intended target, properly position it at the treatment site and, in more advanced research applications, visualize the treatment delivery. This contribution reviews the main role of imaging in modern external beam radiation therapy, with special emphasis on emerging ion beam therapy techniques, which aim at exploiting the favourable properties of ion interaction in…
FLASH is a new treatment modality that requires optimization of dose, dose rate, and LET. Here we validate these three quantities under FLASH conditions, which includes the quantum uncertainty in the time-dependent instantaneous dose rate (IDR) curves and LET spectra that underlie the newly proposed integrated optimization framework. Measurements of dose, IDR, and LET were performed at the Emory Proton Therapy Center using a FLASH proton beam with a nominal energy of 250 MeV and a 3D printed ridge filter. Because 3D printing resin is made from a proprietary chemical formula, we developed a met…
Compact dose delivery of laser-accelerated high-energy electron beams towards radiotherapy applications