放射治疗自动计划:一项跨模态与方案研究

Automatic treatment planning for radiotherapy: a cross-modality and protocol study

Gregory Szalkowski, Xuanang Xu, Shiva Das, Pew-Thian Yap, Jun Lian

AI总结:

本研究验证了仅用IMRT计划训练的UNet模型可跨模态生成剂量预测,并表明将预测作为约束整合进MCO工作流比直接剂量模拟更灵活,能缩短计划时间并降低质量差异。

摘要:

本研究探讨了在一种模态上训练的模型所生成的三维剂量预测在跨模态自动计划工作流中的适用性。此外,我们还探索了整合多准则优化器对将预测适配到不同临床偏好的影响。利用先前创建的内部三阶段UNet模型(该模型在2020年AAPM OpenKBP挑战数据集上训练,包含340例头颈部计划,采用9野静态IMRT计划),我们回顾性地为20例患者生成了剂量预测。这些剂量预测被用于通过Raystation中的回退计划功能生成可交付的IMRT、VMAT和Tomotherapy计划。可交付计划基于主要临床目标与剂量预测进行了评估。还使用基于MCO的优化生成了一组新计划,其中将预测剂量值作为约束条件。模拟方法在不同模态间准确复现了预测的剂量分布,仅在脊髓和外轮廓最大剂量上存在轻微偏差。MCO定制显著降低了我院优先考虑的OAR所受剂量,同时保持了靶区覆盖。所有测试计划均满足临床可交付性标准,交付QA伽马分析通过率高于98%。我们的研究结果表明,仅在IMRT计划上训练的模型能够为多种模态的计划制定做出贡献。此外,将预测作为约束条件整合到基于MCO的工作流中,而非直接进行剂量模拟,为治疗计划提供了一种灵活的、热启动的方法。综合来看,这些方法有潜力显著缩短计划周转时间并降低质量差异,无论是在能够训练内部模型的高资源医疗中心,还是在能够以最小工作量适配其他机构模型的小型中心。

英文摘要:

This study investigates the applicability of 3D dose predictions from a model trained on one modality to a cross-modality automated planning workflow. Additionally, we explore the impact of integrating a multi-criteria optimizer on adapting predictions to different clinical preferences. Using a previously created three-stage UNet in-house model trained on the 2020 AAPM OpenKBP challenge dataset (340 head and neck plans, planned using 9-field static IMRT), we retrospectively generated dose predictions for 20 patients. These dose predictions were used to generate deliverable IMRT, VMAT, and Tomotherapy plans using the fallback plan functionality in Raystation. The deliverable plans were evaluated against the dose predictions based on primary clinical goals. A new set of plans was also generated using MCO-based optimization with predicted dose values as constraints. The mimicking approach accurately replicated the predicted dose distributions across different modalities, with slight deviations in spinal cord and external contour maximum doses. MCO customization significantly reduced doses to OARs prioritized by our institution while maintaining target coverage. All tested plans met clinical deliverability standards, evidenced by a delivery QA gamma analysis passing rate above 98%. Our findings show that a model trained only on IMRT plans can contribute to planning across various modalities. Additionally, integrating predictions as constraints in an MCO-based workflow, rather than direct dose mimicking, enables a flexible, warm-start approach for treatment planning. Together, these approaches have the potential to significantly decrease plan turnaround time and quality variance, both at high resource medical centers that can train in-house models, and smaller centers that can adapt a model from another institution with minimal effort.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑