临床靶区分布加权放疗优化的影响

Implications of Clinical Target Distribution Weighted Radiotherapy Optimization

Ivar Bengtsson, Anders Forsgren, Albin Fredriksson

AI总结:

本文通过理论框架与一维、三维模体实验,将 CTD 加权放疗计划同不同 CTV 外扩边界比较,揭示其在保护危及器官时的剂量维持优势及计算效率。

摘要:

在放射治疗中,针对疑似含有微观肿瘤细胞的区域进行勾画和计划设计,本质上是一项充满不确定性的任务。最近提出的 clinical target distribution(CTD,临床靶区分布)是传统 clinical target volume(CTV,临床靶区)的一种替代方案,并已展现出初步前景。此前,在计划中使用 CTD 主要是与常规界定的 CTV 进行比较评估。我们提议将 CTD 方法与不同大小的 CTV 外扩边界进行比较,这些边界取决于肿瘤浸润概率被认为具有相关性的阈值。首先,本文提出一个理论框架,关注在充分靶区覆盖概率与高剂量相关惩罚之间优化权衡。我们从该框架推导出传统的基于 CTV 的计划设计,并将其与 CTD 方法进行对比。通过与处理几何不确定性的既有方法相比较,进一步阐明这些方法的适用情境。其次,在一维和三维模体上,我们将通过改变靶区目标函数权重而生成的一组 CTD 计划,与通过同时改变靶区权重和 CTV 外扩边界大小而生成的一组计划进行比较。结果表明,在近最低靶区剂量为最高优先级的情形下,基于 CTD 的计划在各评价标准之间产生的权衡略缺乏效率。然而,在保护邻近危及器官至关重要的情形下,CTD 更善于在靶区中心方向维持足够高的剂量。我们得出结论:基于 CTD 的计划设计是一种针对勾画不确定性进行计划设计的计算高效方法,但其对剂量分布不可避免的影响不应被忽视。

英文摘要:

Delineating and planning with respect to regions suspected to contain microscopic tumor cells is an inherently uncertain task in radiotherapy. The recently proposed \textit{clinical target distribution} (CTD) is an alternative to the conventional \textit{clinical target volume} (CTV), with initial promise. Previously, using the CTD in planning has primarily been evaluated in comparison to a conventionally defined CTV. We propose to compare the CTD approach against CTV margins of various sizes, dependent on the threshold at which the tumor infiltration probability is considered relevant. First, a theoretical framework is presented, concerned with optimizing the trade-off between the probability of sufficient target coverage and the penalties associated with high dose. From this framework we derive conventional CTV-based planning and contrast it with the CTD approach. The approaches are contextualized further by comparison with established methods for managing geometric uncertainties. Second, for both a one- and a three-dimensional phantom, we compare a set of CTD plans created by varying the target objective function weight against a set of plans created by varying both the target weight and the CTV margin size. The results show that CTD-based planning gives slightly inefficient trade-offs between the evaluation criteria for a case in which near-minimum target dose is the highest priority. However, in a case when sparing a proximal organ at risk is critical, the CTD is better at maintaining sufficiently high dose toward the center of the target. We conclude that CTD-based planning is a computationally efficient method for planning with respect to delineation uncertainties, but that the inevitable effects on the dose distribution should not be disregarded.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑