arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 1609.00740physics.med-ph
收藏

使用基于体素的剂量预测和剂量模拟方法的头颈部放射治疗全自动治疗计划

Fully Automated Treatment Planning for Head and Neck Radiotherapy using a Voxel-Based Dose Prediction and Dose Mimicking Method

Chris McIntosh, Mattea Welch, Andrea McNiven, David A. Jaffray, Thomas G. Purdie

摘要:

最近在自动放射治疗计划中的工作已经使用基于历史治疗计划的机器学习来直接从计划图像推断新患者的空间剂量分布。我们提出了一种基于图谱的方法,该方法在训练数据库中学习每个患者的剂量预测模型(图谱),然后学习将新患者与最相关的图谱相匹配。该方法创建空间剂量目标,其指定期望的每体素剂量,并且因此取代指定剂量体积目标的任何要求,以传达治疗计划的目标。概率剂量分布从最相关的图谱中推断,并使用条件随机场进行定标,以确定最可能的剂量空间分布,从而为相关的感兴趣区域产生特定的剂量先验(直方图)。然后,基于体素的剂量模拟将预测的剂量分布转换为可递送的治疗计划剂量分布。在这项研究中,我们研究了接受IMRT和VMAT治疗的右侧orbiliaynx头颈部患者的自动计划。我们使用54个训练和12个独立测试患者的数据库比较了我们的剂量预测管道的四个版本。我们的初步结果是有希望的;与临床相比,自动计划在7例患者中实现了更多的剂量评价标准,在4例患者中实现了相同数量的剂量评价标准。总体而言,自动化计划达到的标准相对数量高于临床(17 vs 8),自动化计划显示出对风险器官的保留增加(52 vs 44)和更好的靶覆盖/均匀性(41 vs 31)。

英文摘要:

Recent works in automated radiotherapy treatment planning have used machine learning based on historical treatment plans to infer the spatial dose distribution for a novel patient directly from the planning image. We present an atlas-based approach which learns a dose prediction model for each patient (atlas) in a training database, and then learns to match novel patients to the most relevant atlases. The method creates a spatial dose objective, which specifies the desired dose-per-voxel, and therefore replaces any requirement for specifying dose-volume objectives for conveying the goals of treatment planning. A probabilistic dose distribution is inferred from the most relevant atlases, and is scalarized using a conditional random field to determine the most likely spatial distribution of dose to yield a specific dose prior (histogram) for relevant regions of interest. Voxel-based dose mimicking then converts the predicted dose distribution to a deliverable treatment plan dose distribution. In this study, we investigated automated planning for right-sided oropharaynx head and neck patients treated with IMRT and VMAT. We compare four versions of our dose prediction pipeline using a database of 54 training and 12 independent testing patients. Our preliminary results are promising; automated planning achieved a higher number of dose evaluation criteria in 7 patients and an equal number in 4 patients compared with clinical. Overall, the relative number of criteria achieved was higher for automated planning versus clinical (17 vs 8) and automated planning demonstrated increased sparing for organs at risk (52 vs 44) and better target coverage/uniformity (41 vs 31).

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑