本研究针对仅透射束质子FLASH计划正常组织保护不足的问题,提出透射束结合单能展宽布拉格峰的混合逆向优化方法,经肺部病例验证,该方法在维持靶区剂量均匀性与FLASH剂量率覆盖的同时可提升危及器官保护效果。

摘要:

仅采用透射束(TBs)的超高剂量率(FLASH)质子计划在正常组织保护方面存在局限性。已有研究证实,具备FLASH剂量率的单能展宽布拉格峰(SESOBPs)可用于质子FLASH计划。本研究开发了一种混合逆向优化方法,将TBs与SESOBPs结合(TB-SESOBP)用于FLASH计划。SESOBPs通过预先设计的通用条形脊形滤波器展宽布拉格峰(BPs)生成,并通过射程移位器放置在靶区中心,以实现靶区内均匀剂量。优化过程中对SESOBPs和TBs逐野全采样,支持自动点选择与权重调整。针对5例肺部病例,从三维剂量与剂量率分布方面,将TB-SESOBP计划与仅透射束(TB-only)计划、透射束结合布拉格峰(TB-BP)计划进行对比验证。与TB-only计划相比,TB-SESOBP计划的脊髓平均D1.2cc大幅降低41%,肺平均V7Gy与V7.4Gy中度降低最高达17%,靶区剂量均匀性略有提升。TB-SESOBP计划与TB-BP计划的剂量均匀性相当。此外,对于靶区相对较大的病例,TB-SESOBP计划在肺部保护方面较TB-BP计划有显著提升。三种计划的靶区均完全覆盖FLASH剂量率。对于危及器官(OARs),TB-only计划实现了V40Gy/s=100%,另外两种计划的V40Gy/s>85%。本研究证实,TB-SESOBP混合计划可实现质子治疗的FLASH剂量率。该混合计划在维持高靶区剂量均匀性的同时,在改善危及器官保护方面具有巨大潜力,且有望应用于自适应放疗。

英文摘要:

Ultra-high dose rate (FLASH) proton planning with only transmission beams (TBs) has limitations in normal tissue sparing. The single-energy spread-out Bragg peaks (SESOBPs) of FLASH dose rate have been demonstrated feasible for proton FLASH planning. A hybrid inverse optimization method was developed to combine the TBs and SESOBPs (TB-SESOBP) for FLASH planning. The SESOBPs were generated from spreading out the BPs by pre-designed general bar ridge filters and placed at the central target by range shifters to obtain a uniform dose within the target. The SESOBPs and TBs were fully sampled field-by-field allowing automatic spot selection and weighting in the optimization process. The TB-SESOBP plans were validated in comparison with the TB only (TB-only) plans and the plans with the combination of TBs and BPs (TB-BP) regarding 3D dose and dose rate distributions for five lung cases. Comparing to the TB-only plans, the mean spinal cord D1.2cc drastically reduced 41%, the mean lung V7Gy and V7.4Gy moderately reduced by up to 17% and the target dose homogeneity slightly increased in the TB-SESOBP plans. Comparable dose homogeneity was achieved in both TB-SESOBP and TB-BP plans. Besides, prominent improvements were achieved in lung sparing for the cases of relatively large targets by the TB-SESOBP plans comparing to the TB-BP plans. The targets were fully covered with the FLASH dose rate in all the three plans. For the OARs, V40Gy/s = 100% was achieved by the TB-only plans while V40Gy/s > 85% was obtained by the other two plans. We have demonstrated that the hybrid TB-SESOBP planning was feasible to achieve FLASH dose rate for proton therapy. The hybrid TB-SESOBP planning has great potential in improving OAR sparing while maintaining high target dose homogeneity, and can be potentially implemented for adaptive radiotherapy.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑