Ultra-high dose rate (FLASH) proton planning with only transmission beams (TBs) has limitations in normal tissue sparing. The single-energy spread-out Bragg peaks (SESOBPs) of FLASH dose rate have been demonstrated feasible for proton FLASH planning. A hybrid inverse optimization method was developed to combine the TBs and SESOBPs (TB-SESOBP) for FLASH planning. The SESOBPs were generated from spreading out the BPs by pre-designed general bar ridge filters and placed at the central target by range shifters to obtain a uniform dose within the target. The SESOBPs and TBs were fully sampled field-by-field allowing automatic spot selection and weighting in the optimization process. The TB-SESOBP plans were validated in comparison with the TB only (TB-only) plans and the plans with the combination of TBs and BPs (TB-BP) regarding 3D dose and dose rate distributions for five lung cases. Comparing to the TB-only plans, the mean spinal cord D1.2cc drastically reduced 41%, the mean lung V7Gy and V7.4Gy moderately reduced by up to 17% and the target dose homogeneity slightly increased in the TB-SESOBP plans. Comparable dose homogeneity was achieved in both TB-SESOBP and TB-BP plans. Besides, prominent improvements were achieved in lung sparing for the cases of relatively large targets by the TB-SESOBP plans comparing to the TB-BP plans. The targets were fully covered with the FLASH dose rate in all the three plans. For the OARs, V40Gy/s = 100% was achieved by the TB-only plans while V40Gy/s > 85% was obtained by the other two plans. We have demonstrated that the hybrid TB-SESOBP planning was feasible to achieve FLASH dose rate for proton therapy. The hybrid TB-SESOBP planning has great potential in improving OAR sparing while maintaining high target dose homogeneity, and can be potentially implemented for adaptive radiotherapy.
Current Views on Mechanisms of the FLASH Effect in Cancer Radiotherapy
Peking University(北京大学);the Second Affiliated Hospital of Wenzhou Medical University(温州医科大学附属第二医院);College of Chemistry and Molecular Engineering, Peking University(北京大学化学与分子工程学院);Sun Yat-sen University(中山大学);KIRI Precision Particle Therapy Flash Technologies Research Center(基锐精准粒子治疗闪速技术研究中心);The University of Hong Kong-Shenzhen Hospital(香港大学深圳医院)
An in-silico study of conventional and FLASH radiotherapy iso-effectiveness: Radiolytic oxygen depletion and its potential impact on tumor control probability
Instituto de Investigación Sanitaria de Santiago (IDIS)(圣地亚哥卫生研究所);Universidade de Santiago de Compostela(圣地亚哥德孔波斯特拉大学);Complexo Hospitalario Universitario de Santiago(圣地亚哥大学医院综合体)
Beam monitoring for radiotherapy from conventional to FLASH dose rates using Low Gain Avalanche Silicon detectors
Universidad de Sonora(索诺拉大学);University of Kansas(堪萨斯大学);Washington University School of Medicine(华盛顿大学医学院);Rice University(莱斯大学);University of Kansas Cancer Center(堪萨斯大学癌症中心);The University of Texas MD Anderson Cancer Center(德克萨斯大学安德森癌症中心)
Potential pof laser-driven VHEEs towards FLASH radiotherapy: Monte Carlo dosimetric study of single-field pencil beam scanning of a brain tumor
Intense Laser Irradiation Laboratory, CNR-INO(强激光辐照实验室,CNR-INO);Istituto Nazionale di Fisica Nucleare, Sezione di Pisa(意大利国家核物理研究所,比萨分部);Clinica S.Rossore(S.Rossore诊所);CNR-IFC;Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室)
Review of oxygen measurement and relevance to the mechanisms of FLASH radiotherapy
Thayer School of Engineering at Dartmouth(达特茅斯学院泰耶尔工程学院);Giesel School of Medicine at Dartmouth(达特茅斯学院吉塞尔医学院);University of Wisconsin School of Medicine and Public Health(威斯康星大学医学院和公共卫生学院)
Dependence of the Radical Dynamics on the Beam Temporal Profile in FLASH Radiotherapy
State Key Laboratory of Nuclear Physics and Technology and Institute of Heavy Ion Physics, School of Physics, Peking University(北京大学物理学院重离子物理研究所核物理与技术国家重点实验室);Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education), Department of Radiation Oncology, Peking University Cancer Hospital & Institute(北京大学肿瘤医院暨肿瘤研究所放射肿瘤科教育部癌变与转化研究重点实验室);Department of Health Technology and Informatics, The Hong Kong Polytechnic University(香港理工大学健康技术与信息学系);Beijing Laser Acceleration Innovation Center(北京激光加速器创新中心);State Key Laboratory of Heavy Oil Processing, China University of Petroleum(中国石油大学(华东)重油加工国家重点实验室);Guangdong Institute of Laser Plasma Accelerator Technology(广东激光等离子体加速器技术研究所)
Low noise optimization of an electron beam current transformer for conventional radiotherapy up to ultra high dose rate irradiations
超高剂量率电子束,也称为FLASH放射治疗,在一些临床前癌症治疗研究中变得越来越重要。然而,由于在辐照会话期间使用的剂量率,迄今为止不存在实时剂量监测装置。在这项工作中,我们提出了一个束电流互感器(BCT)的发展,从铁磁组件的选择和实现的屏蔽的前端电子设计的基础上的跨阻抗电路,以执行低噪声优化的检测器。BCT样机能够监测1.2 \textmu A ~ 200 mA的束流,信号的上升时间常数优于20 ns,下降速率低于0.05 $\cdot$ s $^{-1}$。初步的现场测量也提出。目标是将实时测量射束电流的BCT系统与监测射束形状和位置的电离室相结合,以提供可靠的剂量监测系统。
Back with Weight: Revisiting Very Heavy Ions for Precision Radiotherapy
GSI Helmholtzzentrum für Schwerionenforschung(GSI重离子研究中心);University of Santiago de Compostela(圣地亚哥德孔波斯特拉大学);Institut Curie, Université PSL(居里研究所,巴黎文理研究大学);Université Paris-Saclay(巴黎萨克雷大学);Technische Universität Darmstadt(达姆施塔特工业大学);University Federico II(那不勒斯费德里科二世大学)
Mixed Ion Beams Enable Simultaneous Treatment and Real-Time Imaging in Carbon Ion Therapy
GSI Helmholtzzentrum für Schwerionenforschung(GSI亥姆霍兹重离子研究中心);University College London(伦敦大学学院);Centro Nazionale di Adroterapia Oncologica (CNAO)(国家肿瘤质子治疗中心);Technische Universität Darmstadt(达姆施塔特工业大学);University Federico II(那不勒斯费德里科二世大学)
An Integrated Biological Optimization framework for proton SBRT FLASH treatment planning allows dose, dose rate, and LET optimization using patient-specific ridge filters
Pulse-Width-Specific Phase Space Informed Universal Beam Modeling for UHDR electron LINAC in FLASH-RT
Thayer School of Engineering, Dartmouth College(达特茅斯学院泰勒工程学院);Dartmouth Cancer Center(达特茅斯癌症中心);School of Medicine, University of Missouri(密苏里大学医学院);IntraOp Medical Corporation(IntraOp医疗公司)
Charge Collection Efficiency in Air-Vented Plane-Parallel Ionisation Chambers at Ultra-High Dose Rates: A Self-Consistent Garfield++ Monte Carlo Model Including Space-Charge Effects and Ion Recombination
Université libre de Bruxelles (ULB)(布鲁塞尔自由大学);Ion Beam Applications SA(离子束应用公司)