利用瞬发γ射线和次级中子作为替代物测量FLASH束流的时间结构
Measurement of the time structure of FLASH beams using prompt gamma rays and secondary neutrons as surrogates
AI总结:
本研究利用AdvaPIX-TPX3和Minipix-TPX3像素化探测器,以瞬发γ射线和次级中子为替代物测量FLASH放疗束流时间结构,验证了在线监测照射时间和扫描时间的可行性,测量精度最高可达0.1%。
摘要:
本研究旨在探究使用像素化半导体探测器在线监测FLASH放疗照射时间(IRT)和扫描时间的可行性。我们采用快速像素化能谱探测器AdvaPIX-TPX3和Minipix-TPX3开展FLASH照射时间结构的测量,其中Minipix-TPX3的部分传感器涂有中子敏感材料。两款探测器几乎无死时间,且具备分辨时间间隔仅数十纳秒的事件的能力,只要避免堆积效应,就能准确测定照射时间。为避免堆积,我们将探测器放置在布拉格峰之外或大散射角位置。\n我们采集了瞬发γ射线和次级中子,基于首个(束流开启)和最后一个(束流关闭)带电粒子的时间戳计算照射时间,同时测量了x、y及对角线方向的扫描时间。我们针对单点、小动物照射野、患者照射野以及脊形过滤器优化照射野开展了上述测量,以验证照射时间的在体在线监测能力,所有测量结果均与设备供应商的日志文件进行了比对。\n单点、小动物照射野和患者照射野的测量值与日志文件的偏差分别在1%、0.3%和1%以内。照射时间的在体监测中,AdvaPIX-TPX3的准确率在0.1%以内,Minipix-TPX3的准确率在6.1%以内。x、y和对角线方向的扫描时间分别为4.0 ms、3.4 ms和4.0 ms。总体而言,AdvaPIX-TPX3测量FLASH照射时间的精度可达1%以内,表明瞬发γ射线是初级质子的良好替代物;Minipix-TPX3的偏差更大,有待进一步研究。y方向60 mm距离下的扫描时间(3.4±0.05 ms)短于x方向24 mm距离下的扫描时间(4.0±0.06 ms),证实了Y磁铁的扫描速度远快于X磁铁。
英文摘要:
We aim to investigate the feasibility of online monitoring of irradiation time (IRT) and scan time for FLASH radiotherapy using a pixelated semiconductor detector. Measurements of the time structure of FLASH irradiations were performed using fast, pixelated spectral detectors, AdvaPIX-TPX3 and Minipix-TPX3. The latter has a fraction of its sensor coated with a neutron sensitive material. With little or no dead time and an ability to resolve events that are closely spaced in time (tens of ns), both detectors can accurately determine IRTs as long as pile-ups are avoided. To avoid pile-ups, we placed the detectors beyond the Bragg peak or at a large scattering angle. We acquired prompt gamma rays and secondary neutrons and calculated IRTs based on timestamps of the first (beam-on) and the last (beam-off) charged species. We also measured scan times in x, y, and diagonal directions. We performed these measurements for a single spot, a small animal field, a patient field, and a ridge filter optimized field to demonstrate in vivo online monitoring of IRT. All measurements were compared to vendor log files. Differences between measurements and log files for a single spot, a small animal field, and a patient field were within 1%, 0.3% and 1%, respectively. In vivo monitoring of IRTs was accurate within 0.1% for AdvaPIX-TPX3 and within 6.1% for Minipix-TPX3. The scan times in x, y, and diagonal directions were 4.0, 3.4, and 4.0 ms, respectively. Overall, the AdvaPIX-TPX3 can measure FLASH IRTs within 1% accuracy, indicating that prompt gamma rays are a good surrogate for primary protons. The Minipix-TPX3 showed a higher discrepancy, suggesting a need for further investigation. The scan times (3.4 \pm 0.05 ms) in the 60-mm distance of y-direction were less than (4.0 \pm 0.06 ms) in the 24-mm distance of x-direction, confirming the much faster scanning speed of the Y magnets than that of X.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。