With increasing patient and staff X-ray radiation awareness, many efforts have been made to develop accurate patient dose estimation methods. To date, Monte Carlo (MC) simulations are considered golden standard to simulate the interaction of X-ray radiation with matter. However, sensitivity of MC simulation results to variations in the experimental or clinical setup of image guided interventional procedures are only limited studied. In particular, the impact of patient material compositions is poorly investigated. This is mainly due to the fact, that these methods are commonly validated in phantom studies utilizing a single anthropomorphic phantom. In this study, we therefore investigate the impact of patient material parameters mapping on the outcome of MC X-ray dose simulations. A computation phantom geometry is constructed and three different commonly used material composition mappings are applied. We used the MC toolkit Geant4 to simulate X-ray radiation in an interventional setup and compared the differences in dose deposition, scatter distributions and resulting X-ray images. The evaluation shows a discrepancy between different material composition mapping up to 20 % concerning directly irradiated organs. These results highlight the need for standardization of material composition mapping for MC simulations in a clinical setup.
We study the energy deposition by light and heavy nuclei in tissue-like media as used for cancer therapy. The depth-dose distributions for protons, $^{3}$He, $^{12}$C, $^{20}$Ne, and $^{58}$Ni nuclei are calculated within a Monte Carlo model based on the GEANT4 toolkit. These distributions are compared with each other and with available experimental data. It is demonstrated that nuclear fragmentation reactions essentially reduce the peak-to-plateau ratio of the dose profiles for deeply penetrating energetic ions heavier than $^{3}$He. On the other hand, all projectiles up to $^{20}$Ne were fou…
PURPOSE: Permanent breast seed implant (PBSI) using 103Pd is emerging as an effective adjuvant radiation technique for early-stage breast cancer. However, clinical dose evaluations follow the water-based TG-43 approach with its considerable approximations. Towards clinical adoption of advanced TG-186 model-based dose evaluations, this study presents a comprehensive investigation for PBSI considering both target and normal tissue doses. METHODS: Dose calculations are performed with the free open-source Monte Carlo (MC) code, egs_brachy, using 2 types of virtual patient models: TG43sim (simulate…
Monte Carlo simulation with PENELOPE (v.~2003) is applied to calculate Leksell Gamma Knife$^{\circledR}$ dose distributions for heterogeneous phantoms. The usual spherical water phantom is modified with a spherical bone shell simulating the skull and an air-filled cube simulating the frontal or maxillary sinuses. Different simulations of the 201 source configuration of the Gamma Knife have been carried out with a simplified model of the geometry of the source channel of the Gamma Knife recently tested for both single source and multisource configurations. The dose distributions determined for …
The SHIELD-HIT transport code, in several versions, has been used for modeling the interaction of therapeutic beams of light nuclei with tissue-equivalent materials for a long time. All versions of the code include useful option of decomposition of the absorbed dose by the linear energy transfer (LET), but this option has not been described and published so far. In this work the procedure of decomposition of the absorbed dose by LET is described and illustrated by using the decomposition of the Bragg curve in water phantom, irradiated by beams of protons, alpha particles, and of ions lithium, …
Objectives: A new dosimetric variable, dose dropping speed (DDS), was proposed and used to evaluate normal tissue sparing among stereotactic radiosurgery (SRS) plans with different prescription isodose lines. Methods: Forty plans were generated for 8 intracranial SRS cases, prescribing to isodose levels (IDLs) ranging from 50% to 90% in 10% increments. Whilst maintaining similar coverage and conformity, plans at different IDLs were evaluated in terms of normal tissue sparing using the proposed DDS. The DDS was defined as the greater decay coefficient in a double exponential decay fit of the do…
It has long been known that radiation biology plays an important role and it is necessary for radiotherapy treatments. The radiation effects on normal and malignant tissues after exposure range from a femtosecond to months and years thereafter [1,2]. Therefore, to optimize treatment, it is crucial to explain and understand these mechanisms [3-5]. Providing a conceptual basis for radiotherapy and identifying the mechanisms and processes that underlie the tumor and normal tissue responses to irradiation can help to explain the observed phenomena [6]. Examples include understanding hypoxia, reoxy…
A novel dose calculation approach was designed based on the application of LSTM network that processes the 3D patient/phantom geometry as a sequence of 2D computed tomography input slices yielding a corresponding sequence of 2D slices that forms the respective 3D dose distribution. LSTM networks can propagate information effectively in one direction, resulting in a model that can properly imitate the mechanisms of proton interaction in matter. The study is centered on predicting dose on a single pencil beam level, avoiding the averaging effects in treatment plans comprised of thousands pencil …
The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle(GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy sources. Dose distribution in the tumor and healthy tissues have been taken into account for both mentioned brachytherapy sources. Also, in a certain point of the eye, the ratio of the absorbed dose by t…
For a century, clinical X-ray imaging has visualised only the attenuation properties of tissue, which fundamentally limits the contrast, particularly in soft tissues like the breast. Imaging based on refraction can overcome this limitation, but so far has been constrained to high-dose ex-vivo applications or required highly coherent X-ray sources, like synchrotrons. It has been predicted that grating interferometry (GI) could eventually allow computed tomography (CT) to be more dose-efficient. However, the benefit of refraction in clinical CT has not been demonstrated so far. Here we show that…
There is experimental and histological evidence that chronic irritation and cell death may cause hyperplasia in the exposed tissue. As the heterogeneous deposition of inhaled radon progeny results in high local doses at the peak of the bronchial bifurcations, it was proposed earlier that hyperplasia occurs in these deposition hot spots upon chronic radon exposure. The objective of the present study is to quantify how the induction of basal cell hyperplasia modulates the microdosimetric consequences of a given radon exposure. For this purpose, numerical epithelium models were generated with sph…
Therapeutic ultrasound is an investigational modality which could potentially be used for minimally invasive treatment of prostate cancer. Computational simulations were used to study the effect of natural physiological variations in tissue parameters on the efficacy of therapeutic ultrasound treatment in the prostate. The simulations were conducted on a clinical ultrasound therapy system using patient computed tomography (CT) data. The values of attenuation, perfusion, specific heat capacity and thermal conductivity were changed within their biological ranges to determine their effect on peak…
Purpose: To propose a theory for the differential tissue sparing of FLASH ultra high dose rates (UHDR) through inter-track reaction-diffusion mechanism. Methods: We calculate the time-evolution of particle track-structures using a system of coupled reaction-diffusion equations on a random network designed for molecular transport in porous and disordered media. The network is representative of the intra- and inter-cellular diffusion channels in tissues. Spatial cellular heterogeneities over the scale of track spacing have been constructed by incorporating random fluctuations in the connectivity…
Purpose: To obtain individualized internal doses with a Monte Carlo method in patients undergoing diagnostic FCH-PET studies and to compare such doses with the MIRD method calculations. Methods: A patient cohort of 17 males were imaged after intravenous administration of a mean FCH activity of 244.3 MBq. The resulting PET/CT images were processed in order to generate individualized input source and geometry files for dose computation with the MC tool GATE. The resulting dose estimates were studied and compared to the MIRD method with two different computational phantoms. Mass correction of the…
Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experienc…
The mechanism responsible for the FLASH effect, normal tissue sparing by ultra-high dose rate (UHDR) irradiation with isoeffective tumor control compared to conventional dose rate (CDR) irradiation, remains undetermined. Here we investigate the contribution of interspur interactions (interactions between radiolytic species of individual particle tracks) to overall radiochemical interactions as a function of irradiation parameters, and suggest an increase in interspur interaction as a potential mechanism for tissue sparing in FLASH radiation therapy. We construct a model that analytically repre…
The effects of gold nanoparticles in 125I brachytherapy dose enhancement on choroidal Melanoma are examined using the Monte Carlo simulation technique. Usually, Monte Carlo ophthalmic brachytherapy dosimetry is performed in a water phantom. However, here, the compositions of human eye have been considered instead of water. Both human eye and water phantoms have been simulated with MCNP5 code. These simulations were performed for a fully-loaded 16 mm COMS eye plaque containing 13 125I seeds. The dose delivered to the tumor and healthy tissues have been calculated in both phantoms, with and with…
This work summarises the results of a comparison organized by EURADOS focused on the usage of the ICRP Reference Computational Phantoms. This activity aimed to provide training for the implementation of voxel phantoms in Monte Carlo radiation transport codes and the calculation of the dose equivalent in organs and the effective dose. This particular case describes a scenario of immersion in a 16N beta source distributed in the air of a room with concrete walls where the phantom is located. Seven participants took part in the comparison of results using GEANT4, TRIPOLI-4 and MCNP family codes, …
Proton scattering in some water and tissue equivalent phantom materials was measured to evaluate their simulation accuracy of water and respective human biological tissues. The measurements were performed on the medical facility of the ITEP synchrotron, proton energy was 219 MeV, a narrow beam was formed by a 3 mm collimator. A stack of plastic slabs was set closely to the collimator hole as a scatterer. Three types of Plastic Water (PW, PW LR and PW DT), lung, cortical bone, adipose and muscle plastics (CIRS Inc., USA) were used in the experiments as the substitutes under investigation and li…
Novel radiotherapy techniques like synchrotron X-ray microbeam radiation therapy (MRT), require fast dose distribution predictions that are accurate at the sub-mm level, especially close to tissue/bone/air interfaces. Monte Carlo physics simulations are recognised to be one of the most accurate tools to predict the dose delivered in a target tissue but can be very time consuming and therefore prohibitive for treatment planning. Faster dose prediction algorithms are usually developed for clinically deployed treatments only. In this work, we explore a new approach for fast and accurate dose esti…
High Intensity Focused Ultrasound (HIFU) is a promising therapy for thermal ablation and hyperthermia, characterised by it noninvasiveness, high penetration depth. Effective HIFU thermo-therapy requires the ability to accurately predict temperature elevation and corresponding thermal dose distribution in target tissues. We report a parametric numerical study of the thermal response and corresponding of thermal dose in a bio-tissue in response to ultrasound. We compared the predictions of tissue models with two, three and seven layers, to ultrasound induced heating at duty cycles ranging from 0…
Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present the design of a new tracking device for monitoring on-line the dose in ion therapy through the detection of secondary charged particles produced by the beam interactions in the patient tissues. In fact, the charged particle emission shape can be correlated with the spatial dose release and the Bragg peak position. The detector uses the information provided …
Background. Absorbed radiation dose to the mandible is an important risk factor in the development of mandibular osteoradionecrosis (ORN) in head and neck cancer (HNC) patients treated with radiotherapy (RT). The prediction of mandibular ORN may not only guide the RT treatment planning optimisation process but also identify which patients would benefit from a closer follow-up post-RT for an early diagnosis and intervention of ORN. Existing mandibular ORN prediction models are based on dose-volume histogram (DVH) metrics that omit the spatial localisation and dose gradient and direction informa…
In the case of radon exposure, the spatial distribution of deposited radioactive particles is highly inhomogeneous in the central airways. The objective of this research is to investigate the consequences of this heterogeneity regarding cellular burdens in the bronchial epithelium and to study the possible biological effects on tissue level. Applying a computational fluid dynamics program, the deposition distribution of inhaled radon daughters has been determined in a bronchial airway model for 23 minutes of work in the New Mexico uranium mine corresponding to 0.0129 WLM exposure. A numerical …
Purpose: To compare two methods that use x-ray spectral information to image externally administered contrast agents: K-edge subtraction and basis-function decomposition (the A-space method), Methods: The K-edge method uses narrow band x-ray spectra with energies infinitesimally below and above the contrast material K-edge energy. The A-space method uses a broad spectrum x-ray tube source and measures the transmitted spectrum with photon counting detectors with pulse height analysis. The methods are compared by their signal to noise ratio (SNR) divided by the patient dose for an imaging task t…
We study the propagation of nucleons and nuclei in tissue-like media within a Monte Carlo Model for Heavy-ion Therapy (MCHIT) based on the GEANT4 toolkit (version 8.2). The model takes into account fragmentation of projectile nuclei and secondary interactions of produced nuclear fragments. Model predictions are validated with available experimental data obtained for water and PMMA phantoms irradiated by monoenergetic carbon-ion beams. The MCHIT model describes well (1) the depth-dose distributions in water and PMMA, (2) the doses measured for fragments of certain charge, (3) the distributions …
Purpose: The presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy-tissue sparing, particularly for techniques like pencil-beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this degraded four-dimensional (4D) dose, they typically have one or more deficiencies such as ... Methods: To quickly compute the 4D-dose, the three main tasks of the calculator were run on graphics processing units (GPUs). These tasks were: simulating the delivery of the plan using…
This study analyses the dose difference for a variety of phantom materials that can be used for Leksell Gamma Knife. These materials have properties that are very similar to the human tissue not including the skull bone. Geant4 was employed in the analysis the dose distributions for collimator helmet sizes of 4mm and 8mm. The phantom had a radius of 80mm. Water, brain, PMMA (Poly-methyl methacrylate) and polystyrene were used as the material types. Results showed no considerable differences for radiation dosimetries depending on the material types. In addition, the polystyrene and PMMA (Poly-m…
Secondary radiation in a radiation therapy environment is considered a cause for post-treatment side effects including secondary carcinogenesis. In a proton-therapy setup, neutrons deliver a considerable extra dose to the patient. Various measurements and calculations of neutron dose suggest a wide range of values for this quantity. This paper provides a comparison between the previously published values and analyzes the Monte Carlo calculated neutron dose from the present work using the neutron cross-section data. The purpose is to provide a range for the convergence of several neutron-absorb…
{\bf Purpose}: To develop a first principle and multi-scale model for normal tissue complication probability (NTCP) as a function of dose and LET for proton and in general for particle therapy with a goal of incorporating nano-scale radio-chemical to macro-scale cell biological pathways, spanning from initial DNA damage to tissue late effects. {\bf Methods}: The method is combination of analytical and multi-scale computational steps including (1) derivation of functional dependencies of NTCP on DNA driven cell lethality in nanometer and mapping to dose and LET in millimeter, and (2) 3D-surface…
In this study, two proton beam delivery designs, passive scattering proton therapy (PSPT) and pencil beam scanning (PBS), were quantitatively compared in terms of dosimetric indices. The GATE Monte Carlo code was used to simulate the proton beam system; and the developed simulation engines were benchmarked with respect to the experimental measurements. A water phantom was used to simulate system energy parameters using a set of depth-dose data in the energy range of 120-235 MeV. To compare the performance of PSPT against PBS, multiple dosimetric parameters including FWHM, peak position, range,…
Carbon ions offer significant advantages for deep-seated local tumors therapy due to their physical and biological properties. Secondary particles, especially neutrons caused by heavy ion reactions should be carefully considered in treatment process and radiation protection. For radiation protection purposes, the FLUKA Code was used in order to evaluate the radiation field at deep tumor therapy room of HIRFL in this paper. The neutron energy spectra, neutron dose and energy deposition of carbon ion and neutron in tissue-like media was studied for bombardment of solid water target by 430MeV/u C…
Purpose: Variations in proton Relative Biological Effectiveness (RBE) with Linear Energy Transfer (LET) remain one of the largest sources of uncertainty in proton radiotherapy. This work seeks to identify physics-based metrics which can be applied to reduce this biological uncertainty. Materials and Methods: Three different physical metrics - dose, dose $\times$ LET and a complexity-weighted dose (CWD, Dose $\times$ (1+$κLET_D$) ) were compared with in vitro experimental studies of proton RBE and clinical treatment plans analysed using RBE models. The biological effects of protons in each syst…
BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and detailed TRT dose calculation. METHODS: The novel application egs_mird is introduced, including its structure and variation reduction approaches. A new egs++ source class egs_internal_source and a mo…
Cancer is a primary cause of morbidity and mortality worldwide. The radiotherapy plays a more and more important role in cancer treatment. In the radiotherapy, the dose distribution maps in patient need to be calculated and evaluated for the purpose of killing tumor and protecting healthy tissue. Monte Carlo (MC) radiation transport calculation is able to account for all aspects of radiological physics within 3D heterogeneous media such as the human body and generate the dose distribution maps accurately. However, an MC calculation for doses in radiotherapy usually takes a great mass of time t…
Purpose: To assess the effects of brain movements induced by heartbeat on dose distributions in synchrotron micro- and mini-beam radiaton therapy and to develop a model to help guide decisions and planning for future clinical trials. Methods: The Monte Carlo code PENELOPE was used to simulate the irradiation of a human head phantom with a variety of micro- and mini-beam arrays, with beams narrower than 100mum and above 500mum, respectively, and with radiation fields of 1cmx2cm and 2cmx2cm. The dose in the phantom due to these beams was calculated by superposing the dose profiles obtained for a…
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater…
This paper consists of two parts.In the first part, the scatter components of computed tomograpahy dose profiles are modeled using various functions including the solution to Riccati's differential equation. These scatter functions are combined with primary components such as a trapezoidal function and a constructed function that uses the analytic continuation of Heaviside step function. A mathematical theory is developed in Banach space. The modeled function is used to accurately fit data from the O-arm cone beam imaging system. In a second part of the paper, an approach to dosimtery is devel…
Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger proximal and distal planned target volume margins. Proton CT can potentially reduce these uncertainties by directly measuring proton stopping power. We aim to demonstrate proton CT imaging with complex porcine samples, to analyze in detail three-dimensional regions of interest, and to compare proton stopping powers directly measured by proton CT to those determined…