Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Upon reducing the dose 300 fold, the phase-retrieved SNR was still almost 10 times larger than the absorption contrast data. This reveals the potential for dose reduction factors in the tens of thousands without loss in image quality, which would have a profound impact on medical and industrial imaging applications.
Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast
Monash University(莫纳什大学);Hudson Institute of Medical Research(哈德森医学研究所);ANSTO, based at the Imaging and Medical Beamline of the Australian Synchrotron(澳大利亚核科学和技术组织(位于澳大利亚同步辐射中心成像与医疗光束线))
CD16: a MATLAB-based application for estimating radiation doses from x-ray guided cardiac catheterizations in children
CD 16是一个基于MATLAB的剂量测定系统,设计用于快速估计X射线引导的心脏导管插入术的器官剂量。CD 16主要用于流行病学研究,其中需要对数千名队列成员进行剂量估计,通常基于有限的暴露信息。剂量估计所需的最低数据为(1)总检查比释动能面积积(PKA),(2)患者体型(年龄或体重),(3)由半值层(HVL,单位mm Al)表示的X射线光谱和(4)检查类型。这些数据可以使用Excel电子表格输入。器官剂量估计值输出到相同的电子表格中。使用将PKA与器官剂量相关的k因子的查找表,针对宽范围的射束角度、六种患者尺寸和两种射野尺寸来估计剂量。使用Monte Carlo代码PCXMC V2.0计算这些K因子。CD 16最初计算由4.8 mm Al HVL表示的射束能量的器官剂量,然后调整到其他射束能量(如果指定)。如果已知,则可以指定光束角度,否则CD 16将根据检查类型分配光束角度。CD 16是使用PCXMC的该剂量测定系统的最终版本。未来的版本将使用通用蒙特卡罗代码MCNP和混合体。
Towards order of magnitude X-ray dose reduction in breast cancer imaging using phase contrast and deep denoising
The University of Melbourne(墨尔本大学);The University of Sydney(悉尼大学);Eastern Health(东部健康);Monash Health(莫纳什健康);Monash University(莫纳什大学);Australian Synchrotron, ANSTO(澳大利亚同步辐射中心,ANSTO);Commonwealth Scientific and Industrial Research Organisation(澳大利亚联邦科学与工业研究组织)
GPU-based Low-dose 4DCT Reconstruction via Temporal Non-local Means
四维计算机断层成像(4DCT)在肿瘤放疗中得到了广泛的应用,可以对胸部和上腹部的肿瘤进行精确的靶区勾画和运动测量。然而,4DCT模拟与比传统CT模拟高得多的成像剂量相关,这是其临床应用中的主要问题。传统上,使用滤波反投影(FBP)算法独立地重建4DCT的每个相位。新算法的基本思想是利用不同相位之间的共同信息,减少重建高质量图像所需的输入信息,从而减少成像剂量。我们提出了一种时间非局部均值(TNLM)方法来探索相位间的相似性。通过最小化由数据保真度项和TNLM正则化项组成的代价函数,同时重建4DCT图像的所有相位。我们利用一个向前向后分裂算法和高斯-雅可比迭代法,有效地解决了最小化问题。该算法还在图形处理器(GPU)上实现,以实现较高的计算速度。我们的重建算法已经过测试的数字NCAT胸部体模在三个低剂量的情况下。与标准FBP算法相比,我们的新算法生成的CT图像视觉效果更好,图像噪声和条纹伪影更少。定量分析表明,使用该算法可以获得更高的对比度噪声比和信噪比。在NVIDIA Tesla C1060 GPU卡上,切片的所有10个相位的总重建时间范围为90至140秒。
Perfusion Imaging and Single Material Reconstruction in Polychromatic Photon Counting CT
School of Industrial and Systems Engineering(工业与系统工程学院);Georgia Institute of Technology(佐治亚理工学院);School of Electrical and Computer Engineering(电气与计算机工程学院);Department of Radiology and Imaging Sciences(放射学与影像科学系);Emory University School of Medicine(埃默里大学医学院);Winship Cancer Institute(Winship癌症研究所);Emory University(埃默里大学);Department of Biomedical Engineering(生物医学工程系)