通过传播基相位对比技术实现婴儿肺部低剂量高分辨率CT

Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast

Monash University(莫纳什大学);Hudson Institute of Medical Research(哈德森医学研究所);ANSTO, based at the Imaging and Medical Beamline of the Australian Synchrotron(澳大利亚核科学和技术组织(位于澳大利亚同步辐射中心成像与医疗光束线))

James A. Pollock, Kaye Morgan, Linda C. P. Croton, Emily J. Pryor, Kelly J. Crossley, Christopher J. Hall, Daniel Hausermann, Anton Maksimenko, Stuart B. Hooper, Marcus J. Kitchen

AI总结:

利用传播基相位对比成像技术,优化了婴儿肺部CT成像的分辨率与辐射剂量,实现了比现有高分辨率CT更优的图像质量,符合澳大利亚婴儿胸部CT辐射标准。

摘要:

许多肺部疾病需要详细的可视化以实现准确的诊断和治疗。高分辨率计算机断层扫描(CT)是无创肺部疾病检测的黄金标准技术,但其较高的离子化辐射剂量对患者构成风险。利用X射线相位信息可能在相等或更低的辐射水平下提高图像分辨率。传播基相位对比成像需要对现有医疗系统进行最小的调整,并且由于肺部空气界面引入的强相位梯度,非常适合肺部成像。本文展示了在澳大利亚同步辐射光源的成像和医疗光束线上的羊群作为儿科患者的模型,使用单色辐射和光子计数探测器。图像质量,相对于辐射剂量进行归一化,作为束能量和传播距离的函数进行了优化,使用最佳条件测试了在极低辐射剂量下的可用图像质量。所得CT图像显示出比现有高分辨率CT系统更优的分辨率,将剂量推至量子极限,以符合当前澳大利亚婴儿胸部CT暴露的<2.5 mSv有效剂量标准。构成的原始投影显示出显著比例的零光子计数像素,这在传统CT中会导致严重的信息损失。相位检索使在传统CT重建的剂量降低1,225±31%的情况下,能够清晰可视化较小的肺部气道, voxel大小仅为75μm。

英文摘要:

Many lung diseases require detailed visualisation for accurate diagnosis and treatment. High-resolution computed tomography (CT) is the gold-standard technique for non-invasive lung disease detection, but it presents a risk to the patient through the relatively high ionising radiation dose required. Utilising the X-ray phase information may allow improvements in image resolution at equal or lower radiation levels than current clinical imaging. Propagation-based phase-contrast imaging requires minimal adaption of existing medical systems, and is well suited to lung imaging due to the strong phase gradients introduced by the lung-air material interfaces. Herein, propagation-based phase contrast CT is demonstrated for large animals, namely lambs, as a model for paediatric patients, using monochromatic radiation and a photon-counting detector at the Imaging and Medical Beamline of the Australian Synchrotron. Image quality, normalised against radiation dose, was optimised as a function of the beam energy and propagation distance, with the optimal conditions used to test the available image quality at very low radiation dose. The resulting CT images demonstrate superior resolution to existing high-resolution CT systems, pushing dose to the quantum limit to comply with current Australian guidelines for infant chest CT exposure of $<2.5\:\text{mSv}$ effective dose. Constituent raw projections are shown to have significant proportions of pixels with zero photon counts that would create severe information loss in conventional CT. Phase retrieval enabled clear visualisation of minor lung airways at doses up to 1,225$\pm$31\% times lower than conventional CT reconstruction, at a voxel size of just 75$\mathrmμ$m.