基于深度学习的实时容积成像用于肺立体定向体部放射治疗:概念验证研究

Deep learning-based Real-time Volumetric Imaging for Lung Stereotactic Body Radiation Therapy: A Proof of Concept Study

Yang Lei, Zhen Tian, Tonghe Wang, Kristin Higgins, Jeffrey D. Bradley, Walter J. Curran, Tian Liu, Xiaofeng Yang

摘要:

由于呼吸运动的内部和内部变化,非常期望在肺立体定向体放射治疗(SBRT)的治疗递送期间提供实时体积图像以用于准确和主动的运动管理。在这项概念验证研究中,我们提出了一种新的生成对抗网络,结合感知监督,从单个2D投影中获得瞬时体积图像。我们提出的网络,名为TransNet,由三个模块组成,即,编码、变换和解码模块。不是仅使用所生成的3D图像与地面真实3D CT图像之间的像距损失来监督网络,而是将特征空间中的感知损失集成到损失函数中以迫使TransNet产生准确的肺边界。对抗性监督也用于提高生成的3D图像的真实感。我们对20例在我们机构接受肺SBRT治疗并接受4D-CT模拟的患者进行了模拟研究,并评估了我们的方法在四种不同投影角度下的有效性和一致性,即,0、30、60和90度。对于每个呼吸时相的3D CT图像集,我们模拟其在这些角度下的2D投影,然后对于每个投影角度,使用患者的9个时相的3D CT图像和相应的2D投影数据进行训练,剩余的时相用于测试。平均绝对误差、归一化MAE、峰值信噪比和结构相似性指数分别为99.3 HU、0.032、23.4 dB和0.949。这些结果证明了我们的2D到3D方法对肺癌患者的可行性和有效性,这为治疗中的实时机载体积成像提供了一种潜在的解决方案,以确保肺SBRT治疗的有效性。

英文摘要:

Due to the inter- and intra- variation of respiratory motion, it is highly desired to provide real-time volumetric images during the treatment delivery of lung stereotactic body radiation therapy (SBRT) for accurate and active motion management. In this proof-of-concept study, we propose a novel generative adversarial network integrated with perceptual supervision to derive instantaneous volumetric images from a single 2D projection. Our proposed network, named TransNet, consists of three modules, i.e., encoding, transformation and decoding modules. Rather than only using image distance loss between the generated 3D images and the ground truth 3D CT images to supervise the network, perceptual loss in feature space is integrated into loss function to force the TransNet to yield accurate lung boundary. Adversarial supervision is also used to improve the realism of generated 3D images. We conducted a simulation study on 20 patient cases, who had received lung SBRT treatments in our institution and undergone 4D-CT simulation, and evaluated the efficacy and consistency of our method for four different projection angles, i.e., 0, 30, 60 and 90 degree. For each 3D CT image set of a breathing phase, we simulated its 2D projections at these angles.Then for each projection angle, a patient's 3D CT images of 9 phases and the corresponding 2D projection data were used for training, with the remaining phase used for testing. The mean absolute error, normalized MAE, peak signal-to-noise ratio and structural similarity index metric achieved by our method are 99.3 HU, 0.032, 23.4 dB and 0.949, respectively. These results demonstrate the feasibility and efficacy of our 2D-to-3D method for lung cancer patients, which provides a potential solution for in-treatment real-time on-board volumetric imaging for accurate dose delivery to ensure the effectiveness of lung SBRT treatment.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑