arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2409.16982physics.med-ph
收藏

针对肺癌的质子弧形治疗(PAT)结合早期能量层与斑点分配(ELSA)与传统调强治疗(IMPT)的剂量学与鲁棒性分析

A dosimetric and robustness analysis of Proton Arc Therapy (PAT) with Early Energy Layer and Spot Assignment (ELSA) for lung cancer versus conventional Intensity modulated therapy (IMPT)

Macarena S. Chocan, Sophie Wuyckens, Damien Dasnoy, Dario Di Perri, Elena Borderias Villarruel, Erik Engwall, John A. Lee, Ana M. Barragán-Montero, Edmond Sterpin

AI总结:

本研究比较了ELSA-PAT与IMPT在肺癌治疗中的剂量学与鲁棒性,发现两者靶区覆盖相当,PAT适形度更好但心脏毒性增加且对相互作用效应鲁棒性较低。

摘要:

背景与目的:IMPT在肺癌治疗中面临挑战,例如在摆位误差、射程误差和相互作用效应下维持运动肿瘤的计划鲁棒性。质子弧形治疗(PAT)是一种替代方案,可维持靶区覆盖,潜在改善危及器官(OAR)的 sparing,减少束流递送时间(BDT),并提升患者体验。我们旨在进行IMPT与ELSA-PAT之间的系统计划比较研究,以评估其在肺癌治疗中的潜力。材料与方法:回顾性比较了14例肺ELSA-PAT计划与IMPT计划。执行了4D最坏情况极小极大鲁棒优化,包含84种场景(3%,3 mm)。剂量学评估包括标称和最坏情况场景下的靶区(CTV)和重要OAR。评估了最相关的正常组织并发症概率(NTCP)、靶区覆盖对相互作用效应的鲁棒性以及束流递送时间(BDT)。结果:CTV D95%和D98%在比较中无显著差异。PAT表现出更好的适形度,提高了66%(p = 0.00012),但心脏平均剂量(HMD)更高(23%)。PAT的NTCP 2年死亡风险增加了2%。各技术的总BDT相当。考虑D1%(1.0±0.8 Gy vs 1.1±1.4 Gy)和D98%带宽(0.9±0.9 Gy vs 1.1±1.3 Gy),IMPT对相互作用效应的鲁棒性优于PAT。解释:两种技术对靶区体积提供相似的剂量覆盖水平。尽管PAT改善了剂量适形度,但较高的HMD转化为增加的心脏毒性,推测归因于所选计划方法和OAR与靶区的邻近。增加的能量层和斑点提高了PAT的束流递送时间,尽管这可能改善日常治疗工作流程。

英文摘要:

Background and purpose: IMPT faces challenges in lung cancer treatment, like maintaining plan robustness for moving tumors against setup, range errors, and interplay effects. Proton Arc Therapy (PAT) is an alternative to maintain target coverage, potentially improving organ at risk (OAR) sparing, reducing beam delivery time (BDT), and enhancing patient experience. We aim to perform a systematic plan comparison study between IMPT and ELSA-PAT to assess its potential for lung cancer treatment. Material and Methods: 14 Lung ELSA-PAT plans were compared retrospectively with IMPT plans. 4D worst-case minimax robust optimization was performed, including 84 scenarios (3%,3 mm). Dosimetry assessment included target (CTV) and important OARs, on nominal and worst-case scenarios. Most relevant normal tissue complication probabilities (NTCP), target coverage robustness against interplay effect and beam delivery time (BDT) were evaluated. Results: CTV D95% and D98% showed no significant difference in comparison. PAT demonstrated better conformality by 66% (p = 0.00012) but delivered a higher heart mean dose (HMD,23%). There was a 2% increase in NTCP 2-year mortality risk with PAT. Total BDT was comparable among techniques. IMPT was more robust than PAT against interplay effect, considering both D1% (1,0 $\pm$ 0.8 Gy vs 1.1 $\pm$ 1.4 Gy) and D98% bandwidths (0.9$\pm$0.9 Gy vs 1.1 $\pm$ 1.3 Gy). Interpretation: both techniques provide a similar level of dose coverage to the target volume. Although PAT improved dose conformality, higher HMD translated into increased heart toxicity, presumably due to chosen planning methodology and OAR proximity to target. Increased energy layers and spots raised PAT beam delivery time, although it could improve daily treatment workflow.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑