灌注成像与单材料重建在多能X射线计数CT中的应用
Perfusion Imaging and Single Material Reconstruction in Polychromatic Photon Counting CT
AI总结:
本文提出VI-PRISM算法,用于低剂量灌注CT中的单材料重建,实现比传统方法更精确且更高效的对比剂浓度成像。
摘要:
背景:灌注计算机断层扫描(CT)用于成像对比剂在体内的动态变化,并是医学影像中X射线剂量最高的扫描类型。最近,一种基于单调变分不等式(VI)的理论验证重建算法被提出用于单材料多能X射线计数CT,并在低剂量成像中显示出有希望的早期结果。目的:我们适应这种重建算法用于灌注CT,以在静态背景组织已知的情况下重建对比剂浓度图;我们将这种方法称为VI-PRISM(基于VI的灌注成像和单材料重建)。我们使用具有不同浓度水和碘的数字假体来评估其在低剂量灌注CT中的潜力。方法:模拟的碘浓度范围从0.05到2.5 mg/ml。模拟的X射线源发射最高至100 keV的光子,平均强度从10^5下降到10^2个光子每探测器元素。断层投影的数量从984减少到8,以表征光子分配在视图和强度之间的权衡。结果:我们比较了VI-PRISM与滤波反投影(FBP),发现VI-PRISM在所有测试的源强度水平下都能以低于0.4 mg/ml的误差恢复碘浓度。即使与FBP相比,剂量减少10到100倍,VI-PRISM的重建质量仍与FBP相当。结论:在所有测试的光子预算和角度采样密度下,VI-PRISM实现了更低的RMSE、更少的噪声和更高的信噪比,优于滤波反投影。即使在极端光子受限和稀疏采样条件下,VI-PRISM也能以低于0.4 mg/ml的误差恢复碘浓度,表明VI-PRISM可以支持在光子计数CT中的准确且高效的灌注成像。
英文摘要:
Background: Perfusion computed tomography (CT) images the dynamics of a contrast agent through the body over time, and is one of the highest X-ray dose scans in medical imaging. Recently, a theoretically justified reconstruction algorithm based on a monotone variational inequality (VI) was proposed for single material polychromatic photon-counting CT, and showed promising early results at low-dose imaging. Purpose: We adapt this reconstruction algorithm for perfusion CT, to reconstruct the concentration map of the contrast agent while the static background tissue is assumed known; we call our method VI-PRISM (VI-based PeRfusion Imaging and Single Material reconstruction). We evaluate its potential for dose-reduced perfusion CT, using a digital phantom with water and iodine of varying concentration. Methods: Simulated iodine concentrations range from 0.05 to 2.5 mg/ml. The simulated X-ray source emits photons up to 100 keV, with average intensity ranging from $10^5$ down to $10^2$ photons per detector element. The number of tomographic projections was varied from 984 down to 8 to characterize the tradeoff in photon allocation between views and intensity. Results: We compare VI-PRISM against filtered back-projection (FBP), and find that VI-PRISM recovers iodine concentration with error below 0.4 mg/ml at all source intensity levels tested. Even with a dose reduction between 10x and 100x compared to FBP, VI-PRISM exhibits reconstruction quality on par with FBP. Conclusion: Across all photon budgets and angular sampling densities tested, VI-PRISM achieved consistently lower RMSE, reduced noise, and higher SNR compared to filtered back-projection. Even in extremely photon-limited and sparsely sampled regimes, VI-PRISM recovered iodine concentrations with errors below 0.4 mg/ml, showing that VI-PRISM can support accurate and dose-efficient perfusion imaging in photon-counting CT.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。