arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2310.12499physics.med-ph
收藏

使用低剂量动态对比增强CT的肝脏灌注研究中同时进行空间与时间正则化的定量评估

Quantitative evaluation of simultaneous spatial and temporal regularization in liver perfusion studies using low-dose dynamic contrast-enhanced CT

Kenya Murase, Atsushi Nakamoto, Noriyuki Tomiyama

AI总结:

本研究定量评估了低剂量DCE-CT肝脏灌注中不同时空正则化器的性能,发现结合LRSD的总广义变分(LTGV)在估计准确性上最优,有助于选择合适的正则化方法和参数。

摘要:

本研究旨在定量评估在基于低剂量动态对比增强计算机断层扫描(DCE-CT)的肝脏灌注研究中,不同同时空间与时间正则化器的性能。基于临床数据,使用数字肝脏体模模拟慢性肝病(CLD)和肝细胞癌(HCC)。使用正则化器和原始-对偶算法重建低剂量DCE-CT图像。随后,使用双输入单室模型和线性最小二乘法生成肝脏灌注参数(HPP)图像。在CLD模型中,通过计算输入函数(IFs)的曲线下面积(AUCs)来检查正则化器对IFs的影响,并通过计算上述方法获得的HPP值与真实值之间的误差和变异系数(CV)来评估HPP估计的准确性。在HCC模型中,计算肿瘤内外HPP平均值的比率。IFs的AUCs随着正则化参数(RP)值的增加而降低。尽管动脉IF的AUC不显著依赖于正则化器,但门静脉IF的AUC却显著依赖。使用低秩稀疏分解(LRSD)降低了误差和CV。在CLD和HCC模型中,结合LRSD的总广义变分(TGV)(LTGV)在HPP估计准确性和可用RP值范围方面通常优于其他正则化器。然而,由TGV和LTGV获得的HPP图像中的条纹伪影比其他正则化器更显著。结果表明,LRSD和LTGV有助于提高使用低剂量DCE-CT进行HPP估计的准确性并增强其实用性。本研究将有助于为低剂量DCE-CT肝脏灌注研究选择合适的正则化器和/或RP值。

英文摘要:

The purpose of this study was to quantitatively evaluate the performance of different simultaneous spatial and temporal regularizers in liver perfusion studies using low-dose dynamic contrast-enhanced computed tomography (DCE-CT). A digital liver phantom was used to simulate chronic liver disease (CLD) and hepatocellular carcinoma (HCC) based on clinical data. Low-dose DCE-CT images were reconstructed using regularizers and a primal-dual algorithm. Subsequently, hepatic perfusion parameter (HPP) images were generated using a dual-input single-compartment model and linear least-squares method. In the CLD model, the effect of regularizers on the input functions (IFs) was examined by calculating the areas under the curves (AUCs) of the IFs, and the HPP estimation accuracy was evaluated by calculating the error and coefficient of variation (CV) between the HPP values obtained by the above methods and true values. In the HCC model, the ratios of the mean HPP values inside and outside the tumor were calculated. The AUCs of IFs decreased with increasing regularization parameter (RP) values. Although the AUC of arterial IF did not significantly depend on the regularizers, that of portal IF did. The error and CV were reduced using low-rank and sparse decomposition (LRSD). Total generalized variation (TGV) combined with LRSD (LTGV) was generally superior to the other regularizers in terms of HPP estimation accuracy and range of available RP values in both the CLD and HCC models. However, striped artifacts were more remarkable in the HPP images obtained by the TGV and LTGV than in those obtained by the other regularizers. The results suggest that the LRSD and LTGV are useful for improving the accuracy of HPP estimation using low-dose DCE-CT and for enhancing its practicality. This study will help select a suitable regularizer and/or RP value for low-dose DCE-CT liver perfusion studies.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑