Gas Analysis and Monitoring Systems for the RPC Detector of CMS at LHC
M. Abbrescia, A. Colaleo, R. Guida, G. Iaselli, R. Liuzzi, F. Loddo, M. Maggi, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, A. Ranieri, F. Romano, R. Trenta… 展开作者
M. Abbrescia, A. Colaleo, R. Guida, G. Iaselli, R. Liuzzi, F. Loddo, M. Maggi, B. Marangelli, S. Natali, S. Nuzzo, G. Pugliese, A. Ranieri, F. Romano, R. Trentadue, L. Benussi, M. Bertani, S. Bianco, M. A. Caponero, D. Colonna, D. Donisi, F. L. Fabbri, F. Felli, M. Giardoni B. Ortenzi, M. Pallotta, A. Paolozzi, L. Passamonti, B. Ponzio, C. Pucci, G. Saviano G. Polese, I. Segoni, N. Cavallo, F. Fabozzi, P. Paolucci, D. Piccolo, C. Sciacca G. Belli, A. Grelli, M. Necchi, S. P. Ratti, C. Riccardi, P. Torre, P. Vitulo
备注:
9 pages, 8 figures. Presented by Stefano Bianco (Laboratori Nazionali di Frascati dell'INFN) at the IEEE NSS, San Diego (USA), October 2006
The Resistive Plate Chambers (RPC) detector of the CMS experiment at the LHC proton collider (CERN, Switzerland) will employ an online gas analysis and monitoring system of the freon-based gas mixture used. We give an overview of the CMS RPC gas system, describe the project parameters and first results on gas-chromatograph analysis. Finally, we report on preliminary results for a set of monitor RPC.
CMS experiment constructed the fourth Resistive Plate Chamber (RPC) trigger station composed of 144 RPCs to enhance the high momentum muon trigger efficiency at both endcap regions. All new CMS endcap RPC gaps are produced in accordance with QA and QC at the Korea Detector Laboratory (KODEL) in Korea. All qualified gaps have been delivered to three assembly sites: CERN in Switzerland, BARC in India, and Ghent University in Belgium for the RPC detector assembly. In this paper, we present the detailed procedures used in the production of RPC gaps adopted for the CMS upgrade.
The CMS experiment recorded 177.75 /fb of proton-proton collision data during the RUN-1 and RUN-2 data taking period. Successful data taking at increasing instantaneous luminosities with the evolving detector configuration was a big achievement of the collaboration. The CMS RPC system provided redundant information for the robust muon triggering, reconstruction, and identification. To ensure stable data taking, the CMS RPC collaboration has performed detector operation, calibration, and performance studies. Various software and related tools are developed and maintained accordingly. In this pa…
The status of the CMS RPC Gas Gain Monitoring (GGM) system developed at the Frascati Laboratory of INFN (Istituto Nazionale di Fisica Nucleare) is reported on. The GGM system is a cosmic ray telescope based on small RPC detectors operated with the same gas mixture used by the CMS RPC system. The GGM gain and efficiency are continuously monitored on-line, thus providing a fast and accurate determination of any shift in working point conditions. The construction details and the first result of GGM commissioning are described.
Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the radiation background measurements performed with the 2011 and 2012 proton-proton collision data collected by CMS. Emphasis is given to the measurements of the background distribution inside the RPCs. The expected background rates during the future running of the LHC are estimated both from extrapolated measurements and from simulation.
The second LHC long shutdown period (LS2) is an important opportunity for the CMS Resistive Plate Chambers (RPC) to complete their consolidation and upgrade projects. The consolidation includes detector maintenance for gas tightness, HV (high voltage), LV (low voltage) and slow control operation. All services for the RPC Phase-2 upgrade, namely RE3/1 and RE4/1, were anticipated for installation to LS2. This paper summarises the RPC system maintenance and upgrade activities.
The high pseudorapidity ($η$) region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. During the annual Year-End Technical Stops 2022 & 2023, two new layers of improved Resistive Plate Chambers (iRPC) will be added, RE3/1 & RE4/1, which will completely cover the region of $1.8 < |η| < 2.4$ in the endcap. Thus, the additional new chambers will lead to increase efficiency for both trigger and offline reconstruction in the…
In the framework of the High Luminosity LHC upgrade program, the CMS muon group built several different RPC prototypes that are now under test at the new CERN Gamma Irradiation Facility (GIF++). A dedicated Detector Control System has been developed using the WinCC-OA tool to control and monitor these prototype detectors and to store the measured parameters data. Preliminary efficiency studies that set the base performance measurements of CMS RPC for starting aging studies are also presented.
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers (RPCs) and Drift Tube (DT) chambers in the barrel, RPC and Cathode Strip Chambers (CSCs) in the endcap region. In this paper, the first results of the performance of the RPC system during 2015 with the LHC running at 13 TeV is presented. The stability of the RPC performance, in terms of efficiency, cluster size and noise, is reported.
The muon spectrometer of the CMS (Compact Muon Solenoid) experiment at the Large Hadron Collider (LHC) is equipped with a redundant system made of Resistive Plate Chambers and Drift Tube in barrel and RPC and Cathode Strip Chamber in endcap region. In this paper, the operations and performance of the RPC system during the first three years of LHC activity will be reported. The stability of RPC performance, such as efficiency, cluster size and noise, will be reported. Finally, the radiation background levels on the RPC system have been measured as a function of the LHC luminosity. Extrapolation…
CMS experiment will use Resistive Plate Chambers (RPCs) as dedicated muon trigger detectors. The first 24 RPCs for the barrel muon system of the CMS experiment have been assembled and tested. A brief description of the cosmic muon telescope used for the tests is given. The preliminary results for the chamber performance are presented.
The CMS experiment collected around 150 fb$^{-1}$ of proton-proton collision data at $\sqrt{s}$ = 13 TeV during the Run-2 data taking period of LHC. The CMS RPC system provided redundant information for robust muon triggering, reconstruction and identification. To ensure stable data taking, the CMS RPC collaboration has performed detector operation, calibration and performance studies. After the end of Run-2, it was started the second LHC long shutdown period (LS2), an important opportunity for maintenance and preparation for the next data taking period (Run-3) and the installation of services…
During Phase-2 of the LHC, known as the High Luminosity LHC (HL-LHC), the accelerator will increase its instantaneous luminosity to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$, delivering an integrated luminosity of 3000 fb$^{-1}$ over 10 years of operation starting from 2027. In view of the HL-LHC, the CMS muon system will be upgraded to sustain efficient muon triggering and reconstruction performance. Resistive Plate Chambers (RPCs) serve as dedicated detectors for muon triggering due to their excellent timing resolution, and will extend $|η|$ (pseudorapidity) up to a region of 2.4. Before Long …
Resistive Plate Chambers have a very important role for muon triggering both in the barrel and in the endcap regions of the CMS experiment at the Large Hadron Collider (LHC). In order to optimize their performance, it is of primary importance to tune the electronic threshold of the front-end boards reading the signals from these detectors. In this paper we present the results of a study aimed to evaluate the effects on the RPC efficiency, cluster size and detector intrinsic noise rate, of variations of the electronics threshold voltage.
The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region), and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. The CMS RPC system confers robustness and redundancy to the muon trigger. The RPC system operation in the challenging background and pileup conditions of the LHC environment is presented. The RPC system provides information to …
The contribution of Resistive Plate Chamber (RPC) to muon reconstruction in CMS has been studied on a sample of muons collected in proton-proton collisions at sqrt(s) = 7 TeV at the LHC in 2011. Muon reconstruction is performed using the all-silicon inner tracker and with up to four stations of gas-ionization muon detectors. Drift Tubes and Cathode Strip Chambers detect muons in the barrel and endcap regions, respectively, and are complemented by the RPC system. Measured distributions of reconstructed hits in the RPCs crossed by muons from Z decays with a transverse momentum pT above 20 GeV/c …
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6 \cdot 10^{34}$ cm$^{-2}$s$^{-1}$. The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to 2 kHz/cm$^2$ ( including a safety factor 3 ) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC t…
The CMS RPC muon detector utilizes a gas recirculation system called closed loop (CL) to cope with large gas mixture volumes and costs. A systematic study of CL gas purifiers has been carried out over 400 days between July 2008 and August 2009 at CERN in a low-radiation test area, with the use of RPC chambers with currents monitoring, and gas analysis sampling points. The study aimed to fully clarify the presence of pollutants, the chemistry of purifiers used in the CL, and the regeneration procedure. Preliminary results on contaminants release and purifier characterization are reported.
We report a systematic study of charge distribution dependency of CMS Resistive Plate Chamber (RPC) on gap thickness. Prototypes of double-gap RPCs with six different gap thickness ranging from from 1.0 to 2.0 mm in 0.2-mm steps have been built with 2-mm-thick phenolic high-pressure-laminated plates. The efficiencies of the six gaps are measured as a function of the effective high voltages. We report that the strength of the electric fields of the gap is decreased as the gap thickness is increased. The distributions of charges in six gaps are measured. The space charge effect is seen in the ch…
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.
The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the $η$ coverage to ensure a reliable system for the High Luminosity Large Hadron Collider (HL-LHC) period. The Resistive Plate Chambers (RPCs) system will upgrade the off-detector electronics (called link system) of the chambers currently installed chambers and place improved RPCs (iRPCs) to cover the high pseudo$-$rapidity region, a challenging region for muon reconstruction in terms of background and momentum resolution. In order to find the best option for …
In the High Luminosity Large Hadron Collider (HL-LHC) program, during the next years, the instantaneous luminosity will increase up to 5 $\times$ 10$^{34}$ cm$^{-2}$ s$^{-1}$ which means a factor five higher than the nominal LHC. In that period, the present CMS Resistive Plate Chambers (RPC) system will be subjected to background rates higher than those for which the detectors have been designed, which could affect the detector properties and induce aging effects. To study whether the present RPC system can sustain the hard background conditions during the HL-LHC running period, a dedicated lo…
The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover…
The preliminary results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge density of 0.42 C/cm^2, corresponding to about 4 years of LHCb running at the highest background rate. We observe a rise in the dark current and noise measured with source off. The current drawn with source on steadily decreased, possibly indicating an increase of resistivity of the chamber plates. The performance of the chamber, studied with a muon beam under several photon flux…
The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value of 10^34/cm^2/s at 14 TeV. To prepare the machine and also the experiments for this, two long shutdown periods are scheduled for 2013-2014 and 2018-2019. The CMS Collaboration is planning several dete…
Recent results of an aging test performed at the CERN Gamma Irradiation Facility on a single--gap RPC prototype developed for the LHCb Muon System are presented. The results are based on an accumulated charge of about 0.45 C/cm$^2$, corresponding to about 4 years of LHCb running at the highest background rate. The performance of the chamber has been studied under several photon flux values exploiting a muon beam. A degradation of the rate capability above 1 kHz/cm$^2$ is observed, which can be correlated to a sizeable increase of resistivity of the chamber plates. An increase of the chamber da…
The CMS Resistive Plate Chamber (RPC) system has been certified for 10 years of LHC operation. In the next years, during the High luminosity LHC (HL-LHC) phase, the LHC instantaneous luminosity will increase to a factor five more than the existing LHC luminosity. This will subject the present CMS RPC system to background rates and operating conditions much higher with respect to those for which the detectors have been designed. Those conditions could affect the detector properties and introduce nonrecoverable aging effects. A dedicated longevity test is set up in the CERN Gamma Irradiation Fac…
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam…
The requirement of high rate capability for operation at LHC, led 20 years ago to the achievement of Resistive Plate Chambers operated in avalanche mode, thanks to the introduction of new gas mixtures and to the development of the Front-End electronics. The need for a further increase of the rate capability, in view of the upgrades of LHC, is imposing new detector geometries with thinner gas gaps and electrodes. Streamer operation of RPCs may still be suitable for low rate experiments, and therefore in this paper a comparison between two different detector geometries, the old standard and the …
The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at INFN Lecce site and delivered to CERN, for being integrated in the final muon station of the ATLAS barrel region. We show the key RPC characteristics which qualify the performance of this detector technology as muon trigger chamber in the harsh LHC enviroments. These are dark current, chamber efficiency, noise rate, gas volume tomography, and gas leakage.
In this work several aspects of ATLAS RPC offline monitoring and data quality assessment are illustrated with cosmics data selected by RPC trigger. These correspond to trigger selection, front-end mapping, detection efficiency and occupancy, which are studied in terms of low level quantities such as: RPC off-line hits and standalone tracks. The tools and techniques presented are also extended to the forthcoming LHC p-p beam collisions.
The innermost station of the present ATLAS forward muon detector needs to be upgraded for the super-LHC. We present a proposal to replace it with a sandwiched detector composed of several layers of small-radius Monitored Drift Tube chambers (sMDT) for precision tracking measurement and two stations of multi-gap Resistive Plate Chambers (mRPC) for triggering purpose. We describe the layout of the upgraded detector and the trigger strategy. Several modifications to the RPCs used in the ATLAS barrel region are needed to satisfy the super-LHC requirements. Various studies with the proposed mRPC ti…
Large Resistive Plate Chamber systems have their roots in High Energy Physics experiments at the European Organization for Nuclear Research: ATLAS, CMS and ALICE, where hundreds of square meters of both trigger and timing RPCs have been deployed. These devices operate with complex gas systems, equipped with re-circulation and purification units, which require a fresh gas supply of the order of 6 cm$^{3}$/min/m$^{2}$, creating logistical, technical and financial problems. In this communication, we present a new concept in the construction of RPCs which allowed us to operate a detector at ultra-…
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LH…
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
The response of RPC detectors is highly sensitive to environmental variables. A novel approach is presented to model the response of RPC detectors in a variety of experimental conditions. The algorithm, based on Artificial Neural Networks, has been developed and tested on the CMS RPC gas gain monitoring system during commissioning.
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technolog…
In order to get ready for physics at the LHC, the CMS experiment has to be set up for data taking. The data have to be well understood before new physics can be investigated. On the other hand, there are standard processes, well known from previous experiments and from simulation, which will help to understand the data of the detector in the early days of the LHC.
The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timing for every strip has been developed. Experimental data obtained from cosmic and proton-proton collisions at $\sqrt{s}=7$ TeV have been used for determination of the parameters. A dedicated validation…
The CMS Hadron Calorimeter in the barrel, endcap and forward regions is fully commissioned. Cosmic ray data were taken with and without magnetic field at the surface hall and after installation in the experimental hall, hundred meters underground. Various measurements were also performed during the few days of beam in the LHC in September 2008. Calibration parameters were extracted, and the energy response of the HCAL determined from test beam data has been checked.
The High-Luminosity LHC will put significant demands on trigger systems. To control trigger thresholds, the CMS Collaboration is designing a novel Level-1 track trigger. The Outer Tracker will use modules with pairs of sensor layers to read out hits compatible with charged particles above 2-3 GeV. The system will combine these front-end trigger primitives to reconstruct tracks, providing a measurement of $p_{\mathrm{T}}$, $η$ , $ϕ$, and $z_{0}$. This presentation will introduce the CMS L1 track finding system: the algorithm and its estimated performance, hardware prototypes, and the unique cha…
The CMS experiment will include a pixel detector for pattern recognition and vertexing. It will consist of three barrel layers and two endcaps on each side, providing three space-points up to a pseudoraditity of 2.1. Taking into account the expected limitations of its performance in the LHC environment an 8-9 layer pixel detector for an upgraded LHC is discussed.
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditions and the radiation level inside the detector on different time scales. They detect adverse beam conditions, facilitate beam tuning close to CMS, and measure the doses accumulated in different detector components. Data are taken and analysed independently of the CMS data acquisition, displayed in the control room, and provide inputs to the trigger system and the LHC operators. In case of beam conditions dangerous to…
As part of the Compact Muon Solenoid experiment Phase-II upgrade program, new Resistive Plate Chambers will be installed in the forward region. High background conditions are expected in this region during the high-luminosity phase of the Large Hadron Collider, therefore an improved RPC design has been proposed with a new front-end electronics to sustain a higher rate capability and better time resolution. A new technology is used in the front-end electronics resulting in very low achievable thresholds of the order of several fC. Crucial in the design of the improved RPC is the capability of a…
The CMS Electromagnetic Calorimeter (ECAL) is a high resolution crystal calorimeter operating at the CERN LHC. It is responsible for the identification and precise reconstruction of electrons and photons in CMS, which were crucial in the discovery and subsequent characterization of the Higgs boson. It also contributes to the reconstruction of tau leptons, jets, and calorimeter energy sums, which are vital components of many CMS physics analyses. The ECAL trigger system employs fast digital signal processing algorithms to precisely measure the energy and timing information of ECAL energy deposi…
This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns.
The High Luminosity Large Hadron Collider (HL-LHC) at CERN is expected to collide protons at a centre-of-mass energy of 14\,TeV and to reach the unprecedented peak instantaneous luminosity of 5\,$-$\,7.5\,x\,$10^{34}$\,cm$^{-2}$s$^{-1}$ with an average number of pileup events of 140\,$-$\,200. This will allow the ATLAS and CMS experiments to collect integrated luminosities up to 3000\,$-$\,4000\,fb$^{-1}$ during the project lifetime. To cope with this extreme scenario the CMS detector will be substantially upgraded before starting the HL-LHC, with a plan known as CMS Phase-2 upgrade. The CMS T…
Nowadays RPCs are in a booming phase: they are successfully used in many experiments, including LHC; there are ambitious plans to use them in several upgrade detectors and in some new experiments as well as in various applications. The aim of this paper is to highlight the main challenges which the RPC community may face in the next few years and which were addressed in talks presented at this conference. Examples could be: new and difficult requirements from experiments (and their upgrades) and applications, optimization and improvements of the existing traditional detector designs, improveme…
The limitation of the detection rate of standard bakelite resistive plate chambers (RPC) used as muon detectors in the LHC experiments has prevented the use of such detectors in the high rate regions in both CMS and ATLAS detectors. One alternative to these detectors are RPCs made with low resistivity glass plates ($10^{10} {\rm Ω.cm}$), a beam test at DESY has shown that such detectors can operate at few thousand Hz/cm$^2$ with high efficiency(> 90%)
The forward muon spectrometer of ALICE (A Large Ion Collider Experiment) is equipped with a trigger system made of four planes of Resistive Plate Chambers (RPC), arranged in two stations with two planes each, for a total area of about 140 m2 . The system provides single and di-muon triggers with suitable transverse momentum selection, optimised for the physics of quarkonia and open heavy flavour. In the first two years of data-taking at the Large Hadron Collider (2010 and 2011) the 72 RPCs were operated in highly saturated avalanche mode in both pp and Pb-Pb collisions. The integrated charge w…
The era of High-Luminosity Large Hadron Collider will pose unprecedented challenges for detector design and operation. The planned luminosity of the upgraded machine is 5-7.5 x 10$^{34}$ cm$^{-2}$ s$^{-1}$, reaching an integrated luminosity of 3000-4000 fb$^{-1}$ by the end of 2039. The CMS Tracker detector will have to be replaced in order to fully exploit the delivered luminosity and cope with the demanding operating conditions. The new detector will provide robust tracking as well as input for the first level trigger. This report is focusing on the replacement of the CMS Outer Tracker syste…
In the high luminosity scenario of the LHC (HL-LHC), which will bring the instantaneous luminosity up to 7.5\,$\times$\,$10^{34}$\,cm$^{-2}$s$^{-1}$, ATLAS and CMS will need to operate at up to 200 interactions per 25\,ns beam crossing and reaching up to 4000\,fb$^{-1}$ of integrated luminosity. To achieve their physics goals the experiments will need to improve the tracking and vertexing capability and the ability to selectively trigger on specific physics events at reasonable thresholds. The upgrade of the CMS Tracker requires designing new inner and outer tracking detectors to cope with the…
The ATLAS experiment at the Large Hadron Collider (LHC) employs a trigger system consisting of a first-level hardware trigger (L1) and a software-based high-level trigger. The L1 muon trigger system selects muon candidates, assigns them to the correct LHC bunch crossing and classifies them into one of six transverse-momentum threshold classes. The L1 muon trigger system uses resistive-plate chambers (RPCs) to generate the muon-induced trigger signals in the central (barrel) region of the ATLAS detector. The ATLAS RPCs are arranged in six concentric layers and operate in a toroidal magnetic fie…
At the High Luminosity LHC (HL-LHC), the CMS experiment will need to operate at up to 200 interactions per 25 ns beam crossing time and with up to 4000 fb-1 of integrated luminosity. To achieve the physics goals the experiment needs to improve the tracking resolution and the ability to selectively trigger on specific physics events. The CMS tracker upgrade requires designing a new detector to cope with the HL-LHC conditions. The new Outer Tracker is based on two types of silicon modules (strip-strip and pixel-strip). Each module type has a few types of high-density interconnect hybrid circuits…
The CMS experiment will collect data from the proton-proton collisions delivered by the Large Hadron Collider (LHC) at a centre-of-mass energy up to 14 TeV. The CMS trigger system is designed to cope with unprecedented luminosities and LHC bunch-crossing rates up to 40 MHz. The unique CMS trigger architecture only employs two trigger levels. The Level-1 trigger is implemented using custom electronics. The High Level Trigger is implemented on a large cluster of commercial processors, the Filter Farm. Trigger menus have been developed for detector calibration and for fulfilment of the CMS physic…
The operations of Resistive Plate Chambers in LHC experiments require F-based gases for optimal performance. Recent regulations demand the use of environmentally unfriendly F-based gases to be limited or banned. This report shows results of studies on performance of RPCs operated with a potential eco-friendly gas candidate 1,3,3,3-Tetrafluoropropene, commercially known as HFO-1234ze.