使用试验束、Cosmic Ray和LHC束数据的CMS强子量热计定时和同步性能

Performance of CMS Hadron Calorimeter Timing and Synchronization using Test Beam, Cosmic Ray, and LHC Beam Data

CMS Collaboration

摘要:

本文讨论了CMS强子量能器的时间测量技术和同步系统的设计和性能。时间测量性能的结果,从2004年和2006年采取的测试梁数据。对于能量大于100 GeV的强子簇射,测得的时间分辨率约为1.2 ns。时间同步和时间外的背景抑制结果来自于2008年秋季进行的四特斯拉宇宙运行和LHC束流运行。通道间同步被测量为在2ns内。

英文摘要:

This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within 2 ns.