The energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of sqrt(s)=7 TeV with integrated luminosities of about 5 inverse femtobarns. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are discussed in detail and include the maintenance of the calibration in the challenging radiation environment inside the CMS detector. The energy resolution for electrons from Z-boson decays is better than 2% in the central region of the ECAL barrel (for pseudorapidity abs(eta)<0.8) and is 2-5% elsewhere. The derived energy resolution for photons from 125 GeV Higgs boson decays varies across the barrel from 1.1% to 2.6% and from 2.2% to 5% in the endcaps. The calibration of the absolute energy is determined from Z to e+e- decays to a precision of 0.4% in the barrel and 0.8% in the endcaps.
The CMS detector at the LHC is in the final stages of preparation. The high resolution Electromagnetic Calorimeter, which consists of nearly 76000 lead tungstate crystals, will play a crucial role in the coming physics searches undertaken by CMS. The design, status, and initial performance of the calorimeter, in test beams and with cosmic rays, will be reviewed.
The high flux of charged particles interacting with the CMS Forward Hadron Calorimeter PMT windows introduced a significant background for the trigger and offline data analysis. During Long Shutdown 1, all of the original PMTs were replaced with multi-anode, thin window photomultiplier tubes. At the same time, the back-end electronic readout system was upgraded to μTCA readout. The experience with commissioning and calibration of the Forward Hadron Calorimeter is described as well as the μTCA system. The upgrade was successful and provided quality data for Run 2 data-analysis at 13 TeV.
The Compact Muon Solenoid (CMS) calorimeter regional trigger system is designed to detect signatures of isolated and non-isolated electrons/photons, jets, ?-leptons, and missing and total transverse energy using a deadtimeless pipelined architecture. This system contains 18 crates of custom-built electronics. The pre-production prototype backplane, boards, links and Application-Specific Integrated Circuits (ASICs) have been built and their performance is characterized.
The CASTOR calorimeter is a detector covering the very forward region of the CMS experiment at the LHC. It surrounds the beam pipe with 14 longitudinal modules each of which consisting of 16 azimuthal sectors and allows to reconstruct shower profiles, separate electrons and photons from hadrons and search for phenomena with anomalous hadronic energy depositions. The physics program that can be performed with this detector includes a large variety of different QCD topics. In particular, the calorimeter is supposed to contribute to studies of low-x parton dynamics, diffractive scattering, multi-…
The CASTOR Calorimeter at the CMS experiment is an electromagnetic/hadronic calorimeter which covers the very forward region of the detector (-6.6 < eta < -5.2). CASTOR is a Cherenkov sampling calorimeter, consisting of quartz and tungsten plates, with an overall depth of 10 interaction lengths, able to detect penetrating cascade particles. It is segmented in 16 transversal and 14 longitudinal sections. Surrounding the beam pipe, its design is determined by space constraints and restricted to materials which tolerate a high radiation level. In this presentation we report on the operational exp…
The physics motivation, detector design, triggers, calibration, alignment, simulation, and overall performance of the very forward CASTOR calorimeter of the CMS experiment are reviewed. The CASTOR Cherenkov sampling calorimeter is located very close to the LHC beam line, at a radial distance of about 1 cm from the beam pipe, and at 14.4 m from the CMS interaction point, covering the pseudorapidity range of $-$6.6 $\lt$ $η$ $\lt$ $-$5.2. It was designed to withstand high ambient radiation and strong magnetic fields. The performance of the detector in measurements of forward energy density, jets…
We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that they indicate a strong dose rate effect. The damage for a given dose is larger for lower dose rate exposures. The results agree with previous measurements of dose rate effects, but are stronger due to the very low dose rates probed. We show that the scaling with dose rate is consistent with that expected from diffusion effects.
As part of its HL-LHC upgrade program, CMS is developing a High Granularity Calorimeter (HGCAL) to replace the existing endcap calorimeters. The HGCAL will be realised as a sampling calorimeter, including an electromagnetic compartment comprising 28 layers of silicon pad detectors with pad areas of 0.5 - 1.0 cm2 interspersed with absorbers. Prototype modules, based on 6-inch hexagonal silicon pad sensors with 128 channels, have been constructed and include many of the features required for this challenging detector. In 2016, beam tests of sampling configurations made from these modules have be…
CMS experiment is using Geant4 for Monte-Carlo simulation of the detector setup. Validation of physics processes describing hadronic showers is a major concern in view of getting a proper description of jets and missing energy for signal and background events. This is done by carrying out an extensive studies with test beam using the prototypes or real detector modules of the CMS calorimeter. These data are matched with Geant4 predictions. Tuning of the Geant4 models is carried out and steps to be used in reproducing detector signals are defined in view of measurements of energy response, ener…
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 10 GeV to 3 TeV. The analysis of the simulated data shows that standard calibration using just sampling coefficients for calorimeter parts with different sampling ratio gives nonlinear calorimeter response. Non-linear calibration technique was applied for improving calorimeter energy resolution and restoring the calorimeter linearity.
A template fitting technique for reconstructing the amplitude of signals produced by the lead tungstate crystals of the CMS electromagnetic calorimeter is described. This novel approach is designed to suppress the increased out-of-time pileup contribution to the signal following the reduction of the accelerator bunch spacing from 50 to 25 ns at the start of Run 2 of the LHC. Execution of the algorithm is sufficiently fast for it to be employed in the CMS high-level trigger. It is also used in the offline event reconstruction. Results obtained from simulations and from Run 2 collision data (201…
Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities $|η| <$ 3 and are positioned inside a solenoidal magnet. An outer calorimeter, outside the magnet coil, covers $|η| <$ 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to $|η| <$ 5.19. The initial calibration of the calorimeters was based on results from test b…
The Zero Degree Calorimeter (ZDC) is integral part of the CMS experiment, especially, for heavy ion studies. The design of the ZDC includes two independent calorimeter sections: an electromagnetic section and a hadronic section. Sampling calorimeters using tungsten and quartz fibers have been chosen for the energy measurements. An overview of the ZDC is presented along with a current status of calorimeter's preparation for Day 1 of LHC.
We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam.
The two Zero Degree Calorimeters (ZDCs) of the CMS experiment are located at $\pm 140~$m from the collision point and detect neutral particles in the $|η| > 8.3$ pseudorapidity region. This paper presents a study on the performance of the ZDC in the 2016 pPb run. The response of the detectors to ultrarelativistic neutrons is studied using in-depth Monte Carlo simulations. A method of signal extraction based on template fits is presented, along with a dedicated calibration procedure. A deconvolution technique for the correction of overlapping collision events is discussed.
CMS calorimeter energy calibration was done in the full CMS simulated geometry for the pseudorapidity region eta = 0. The samples of single pion events were generated with a set of incident energies from 5 GeV to 3 TeV and for single electrons from 5 to 500 GeV. The analysis of the simulated data shows that standard calibration using just sampling coefficients for calorimeter parts with different sampling ratio gives nonlinear calorimeter response. Non-linear calibration technique was applied simultaneously for pion and electron beams which is preparation for jets energy reconstruction. It imp…
This paper reports on the commissioning and first running experience of the CMS Zero Degree Calorimeters during December 2009. All channels worked correctly. The ZDCs were timed into the data acquisition system using beam splash events. These data also allowed us to make a first estimate of channel-by-channel variations in gain.
The installation of the High-Luminosity Large Hadron Collider (HL-LHC) presents unprecedented challenges to experiments like the Compact Muon Solenoid (CMS) in terms of event rate, integrated luminosity and therefore radiation exposures. To cope with this new environment, new detectors will be installed during the CMS Phase 2 Upgrade, including the replacement of the calorimeter endcaps with the "High Granularity Calorimeter" (HGCAL), which contains silicon sensors and scintillators as active elements. The silicon sensors will be produced in an 8" wafer process, which is new for high-energy ph…
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
We report on the performance of a prototype CMS Hadron Barrel Calorimeter (HCAL) module in a test beam. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. Placing a lead tungstate crystal electromagnetic calorimeter in front of HCAL affects the linearity and energy resolution of the combined system to hadrons. The data are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation.
The CMS Collaboration is preparing to build replacement endcap calorimeters for the HL-LHC era. The new high-granularity calorimeter (HGCAL) is, as the name implies, a highly-granular sampling calorimeter with approximately six million silicon sensor channels (approx. 1.1cm2 or 0.5cm2 cells) and about 250 thousand channels of scintillator tiles readout with on-tile silicon photomultipliers. The calorimeter is designed to operate in the harsh radiation environment at the HL-LHC, where the average number of interactions per bunch crossing is expected to exceed 140. Besides measuring energy and p…
CMS-HF Calorimeters have been undergoing a major upgrade for the last couple of years to alleviate the problems encountered during Run I, especially in the PMT and the readout systems. In this poster, the problems caused by the old PMTs installed in the detectors and their solutions will be explained. Initially, regular PMTs with thicker windows, causing large Cherenkov radiation, were used. Instead of the light coming through the fibers from the detector, stray muons passing through the PMT itself produce Cherenkov radiation in the PMT window, resulting in erroneously large signals. Usually, …
Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions. The upgraded CMS Outer Tracker and parts of the new CMS High Granularity Calorimeter (HGCAL) will encompass over $50{,}000$ new silicon sensors covering a total area of about $800\,\text{m}^{2}$. The sensor series production requires a dedicated strategy to monitor the quality and stability of the production process. The strategy is based on a test structure…
The CMS hadron Calorimeter is made of alternating layers of scintillating tiles and metals, such as brass or iron. The original photo detectors were hybrid units with a single accelerating gap called Hybrid Photo Diodes (HPD). Scintillating light was transmitted to the HPDs by means of optical fibers. During data taking at the Large Hadron Collider (LHC), the signal strength of scintillator tiles of detector units in the forward region degraded significantly due to the damage related to the amount of radiation to which the scintillator was exposed to. Scintillators suffer damage when exposed t…
Application of sequence learning for predicting radiation damage of the CMS electromagnetic calorimeter
Facultad de Ciencias, Universidad Nacional Autónoma de México(墨西哥国立自治大学理学院);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector. The tiles were exposed to particles produced in proton-proton (pp) collisions at the CERN LHC with a center-of-mass energy of 13 TeV, corresponding to a delivered luminosity of 50 fb$^{-1}$. The measurements are based on readout channels of the HE that were instrumented with silicon photomultipliers, and are derived using data from several sources: a laser calibration system, a movable radioactive source, as well as …
The electromagnetic ealorimeter (ECAL) of the CMS detector has played an important role in the physics program of the experiment, delivering outstanding performance throughout data taking. The High-Luminosity LHC will pose new challenges. The four to five-fold increase of the number of interactions per bunch crossing will require superior time resolution and noise rejection capabilities. For these reasons the electronics readout has been completely redesigned. A dual gain trans-impedance amplifier and an ASIC providing two 160 MHz ADC channels, gain selection, and data compression will be used…
The very-forward energy production in hadron collisions is of paramount importance for the understanding of ultra-high energy cosmic ray air showers. The CASTOR calorimeter of CMS is located at $-6.6 < η< -5.2$ in the phase-space where the peak of energy is deposited at LHC. The composition and characteristics of the particles in this phase-space have a determining impact on the formation of air shower cascades. An overview of various energy measurements performed with CASTOR is reported and possible implications for cosmic ray physics are outlined.
The foreseen upgrade of the LHC to its high luminosity phase (HL-LHC), will maximize the physics potential of the facility. The upgrade is expected to increase the instantaneous luminosity by a factor of 5 and deliver an integrated luminosity of 3000 fb-1 after 10 years of operation. As a result of the corresponding increase in radiation and pileup, the electromagnetic calorimetry in the CMS endcaps will sustain maximum integrated doses of 1.5 MGy and neutron fluences above 1e16 neq/cm2, necessitating their replacement for HL-LHC operation. The CMS collaboration has decided to replace the exis…
The artificial neural network approach is used for separation of signals from a single photon $γ$ and products of the $π^0,η, K^0_s$ meson neutral decay channels on the basis of the data from the CMS electromagnetic calorimeter alone. Rejection values for the three types of mesons as a function of single photon selection efficiencies are obtained for two Barrel and one Endcap pseudorapidity regions and initial $\Et$ of 20, 40, 60 and 100 GeV.
We present the current stage of research progress towards a one-pass, completely Machine Learning (ML) based imaging calorimeter reconstruction. The model used is based on Graph Neural Networks (GNNs) and directly analyzes the hits in each HGCAL endcap. The ML algorithm is trained to predict clusters of hits originating from the same incident particle by labeling the hits with the same cluster index. We impose simple criteria to assess whether the hits associated as a cluster by the prediction are matched to those hits resulting from any particular individual incident particles. The algorithm …
The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.
Physical possibility for bending the LHC protons (or ions) a huge angle of 1-20 degrees in the energy range of 0.45 to 7 TeV by means of a bent channeling crystal of Silicon or Germanium is demonstrated. Such an application can be useful for calibration of CMS (or ATLAS) calorimeters in situ by the LHC beam of precisely known energy. We show by simulations that such an application would be feasible at the LHC, and report the experience of IHEP Protvino in bending 70 GeV protons by 9 degrees (150 mrad) during 10 years in 1994-2004 experiments.
The possibility of separating the $π^0, η, ω$ and $K^0_s$ meson background from the signal photons produced directly in $pp$ collisions is analyzed. The rejection factors for two pseudorapidity regions 0.4<η<1.0$ and 1.6<η<2.0$ and six Et values, 20, 40, 60, 80, 100 and 200 GeV, are calculated for a case when only the calorimeter information is used. The cases of $η, ω$ and $K^0_s$ mesons decaying through the neutral and charged channels are considered separately.
The Compact Muon Solenoid (CMS) detector is a general-purpose experimental setup at the Large Hadron Collider (LHC) at CERN to investigate the production of new particles in the proton-proton collisions at a centre of mass energy 13 TeV. The third run of the data taken is started in April 2022 and will continue till the end of 2025. Then, during a long shutdown time, the existing CMS hadron endcap calorimeter will be replaced with a new high granularity calorimeter (HGCal) designed for the higher LHC luminosity. The HGCal contains the stainless-steel absorber plates with a relative permeabilit…
Jet substructure variables for hadronic jets with transverse momenta in the range from 2.5 TeV to 20 TeV were studied using several designs for the spatial size of calorimeter cells. The studies used the full Geant4 simulation of calorimeter response combined with realistic reconstruction of calorimeter clusters. In most cases, the results indicate that the performance of jet-substructure reconstruction improves with reducing cell size of a hadronic calorimeter from $Δη\times Δϕ= 0.087\times0.087$, which are similar to the cell sizes of the calorimeters of LHC experiments, by a factor of four,…
We report on the response of a prototype CMS hadron calorimeter module to charged particle beams of pions, muons, and electrons with momenta up to 375 GeV/c. The data were taken at the H2 and H4 beamlines at CERN in 1995 and 1996. The prototype sampling calorimeter used copper absorber plates and scintillator tiles with wavelength shifting fibers for readout. The effects of a magnetic field of up to 3 Tesla on the response of the calorimeter to muons, electrons, and pions are presented, and the effects of an upstream lead tungstate crystal electromagnetic calorimeter on the linearity and energ…
The CMS electromagnetic calorimeter (ECAL) is a high-resolution, hermetic, and homogeneous calorimeter made of 75,848 scintillating lead tungstate crystals. Following the discovery of the Higgs boson, the CMS ECAL is at the forefront of precision measurements and the search for new physics in data from the LHC, which recently began producing collisions at the unprecedented energy of 13 TeV. The exceptional precision of the CMS ECAL, as well as its timing performance, are invaluable tools for the discovery of new physics at the LHC Run 2. The excellent performance of the ECAL relies on precise …
The CMS apparatus was identified, a few years before the start of the LHC operation at CERN, to feature properties well suited to particle-flow (PF) reconstruction: a highly-segmented tracker, a fine-grained electromagnetic calorimeter, a hermetic hadron calorimeter, a strong magnetic field, and an excellent muon spectrometer. A fully-fledged PF reconstruction algorithm tuned to the CMS detector was therefore developed and has been consistently used in physics analyses for the first time at a hadron collider. For each collision, the comprehensive list of final-state particles identified and re…
Throughout the year 2011, the Large Hadron Collider (LHC) has operated with an instantaneous luminosity that has risen continually to around 4x10^33cm-2 s-1. With this prodigious high-energy proton collisions rate, efficient triggering on electrons and photons has become a major challenge for the LHC experiments. The Compact Muon Solenoid (CMS) experiment implements a sophisticated two-level online selection system that achieves a rejection factor of nearly 106. The first level (L1) is based on coarse information coming from the calorimeters and the muon detectors while the High-Level Trigger …
This paper discusses a study of tower and cell energy ranges of a hadronic calorimeter for a 100 TeV pp collider. The dynamic energy ranges were estimated using Standard Model jets with transverse momenta above 20 TeV. The simulations were performed using the PYTHIA Monte Carlo model after a fast detector simulation tuned to the ATLAS hadronic calorimeter. We estimate the maximum energy range of towers and cells as a function of lateral cell sizes for several extreme cases of jet transverse energy.
The CMS Detector consists of a large volume silicon tracker immersed in a high four Tesla magnetic field, together with a high resolution/granularity electromagnetic calorimeter and a nearly full solid angle coverage hadronic calorimeter. Particle flow reconstruction provides a global pp-collision event description by exploiting the combined information across all CMS sub-detectors, optimizing the reconstruction and the identification of each particle (photons, electrons, muons, unstable neutral hadrons, charged hadrons and neutral hadrons) in an event. This summary introduces the CMS particle…
The two calorimeters CASTOR and ZDCs enhance the hermeticity of the CMS detector at the LHC by extending the rapidity coverage in the forward region. After having described these detectors, their forward physics capabilities are presented. These latters include the study of parton shower, multiple parton interactions, diffraction and ultra high energy cosmic rays models. The processes to be measured to constrain these topics are multi-jet events with a forward jet, central-forward activity correlation, rapidity gaps and forward neutron production.
A simulation study of energy resolution, position resolution, and $π^0$-$γ$ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the design geometry of the Shashlik calorimeter which was considered as a candidate for CMS endcap for the phase II of LHC running. The methods proposed in this paper can be easily adapted to various geometrical layouts of a sampling calorimeter. Energy resolution is studied for different layouts and different absorber-scintillator combinations of the Shashlik detector. It …
The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for future colliders. As part of its HL-LHC upgrade program, the CMS collaboration is designing a High Granularity Calorimeter to replace the existing endcap calorimeters. It features unprecedented transverse and longitudinal segmentation for both electromagnetic (ECAL) and hadronic (HCAL) compartments. This will facilitate particle-flow calorimetry, where the fine …
The existing CMS endcap calorimeters will be replaced with a High Granularity Calorimeter (HGCAL) for operation at the High Luminosity (HL) LHC. Radiation hardness and excellent physics performance will be achieved by utilising silicon pad sensors and SiPM-on-scintillator tiles with high longitudinal and transverse segmentation. One of the major challenges of the HL-LHC will be the high pileup environment, with interaction vertices spread not only in position, but also in time. In order to efficiently reject particles originating from pileup, precision timing information of the order of 30 ps …
The Particle Flow Algorithms adopted for future $e^{+}e^{-}$ colliders detectors and phase-II CMS upgrade require very high granularity calorimeters to deconvolve the individual contributions of particles in jets. This is especially true for electromagnetic calorimeters (ECAL). For a realistic large detector many technological requirements have to be fulfilled: modularity for industrialization; compact integration of an embedded very front-end electronics featuring large dynamics, low-power and self-triggering; mechanical structure and cooling systems with minimal dead zones. The technological…
While the CMS experiment is currently harvesting LHC collision data at CERN, the performance of its electromagnetic calorimeter (ECAL) is being constantly monitored, and work has started to assess the need for changes to the detector to ensure an adequate performance for High-Luminosity LHC (HL-LHC) running, which is planned for 2022 and beyond. In this paper, results from CMS running, beam tests and laboratory measurements are combined to anticipate the detector performance evolution at the HL-LHC. Further, various R&D studies are illustrated, that will provide a useful choice for electromagn…