Design, construction, and testing of the PandaX-xT cryogenics system
Shanghai Jiao Tong University(上海交通大学);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Sun Yat-Sen University(中山大学);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
Xu Wang, Li Zhao, Xiang Xiao, Xiangyi Cui, Shuaijie Li, Jianglai Liu
The PandaX-xT is a next-generation experiment with broad scientific goals, including the search for dark matter, Neutrinoless Double Beta Decay, and astrophysical neutrinos, using a dual-phase time projection chamber with about 43 tons of liquid xenon. A new cryogenics system of the PandaX-xT is described in this paper. It is developed to handle large mass of liquid xenon efficiently and safely, including two cooling towers for normal operation and one liquid-nitrogen coil for emergency case. Each cooling tower equipped with an AL600 Gifford-McMahon cryocooler features a 1300 W heater, specifically designed to maintain the cold finger's temperature at the desired setpoint. The performance of the cooling tower and the coil has been tested. The cryogenics system with two cooling towers has achieved about 1900~W cooling power at 178~K. The liquid nitrogen coil provides emergency cooling power of more than 1500~W at liquid xenon temperature. For the prototype of a 1-tonne liquid xenon detector, the fluctuation of xenon saturated vapor pressure remains below 1 kPa over one month, while the pressure is around 210~kPa.
Tritiated methane reduction in the PandaX-4T experiment via purge and cryogenic distillation processes
Shanghai Jiao Tong University(上海交通大学);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司);Tsung-Dao Lee Institute(李政道研究所);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province(锦屏深地前沿科学与暗物质四川省重点实验室);Institute of Refrigeration and Cryogenic(制冷与低温研究所);Yantai University(烟台大学)
The throttling refrigeration system for high cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal
SJTU Paris Elite Institute of Technology, Shanghai Jiao Tong University(上海交通大学巴黎卓越工程师学院);New Cornerstone Science Laboratory, Tsung-Dao Lee Institute, Shanghai Jiao Tong University(新Cornerstone科学实验室,汤川秀树研究所,上海交通大学);School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province(四川省锦屏深地下前沿科学与暗物质重点实验室);Vacree Technologies Co., Ltd.(沃瑞科技有限公司);School of Chemical Engineering, Zhengzhou University(郑州大学化学工程与应用学院);School of Physics, Sun Yat-Sen University(中山大学物理学院);Department of Physics, University of Maryland, College Park(马里兰大学帕克分校物理系);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
Cryogenic Ion Trapping Systems with Surface-Electrode Traps
我们提出了两个简单的低温射频离子阱系统,其中低温温度和超高真空压力可以在短短12小时内达到。离子阱在液氦浴低温恒温器或低振动闭合循环低温恒温器中操作。快速的周转时间和缓冲气体冷却的可用性使该系统成为测试表面电极离子阱的理想选择。发现闭合循环低温恒温器的振动振幅低于106nm。我们评估了系统通过加载表面电极离子阱与$^{88}$ Sr $^+$离子使用激光烧蚀,这是兼容的低温环境。使用多普勒冷却,我们观察到小的离子晶体中,光学分辨的离子具有超过2500分钟的捕获寿命。
Optimization studies of silicon remoTES cryogenic calorimeters
Max-Planck-Institut für Physik(马克斯·普朗克物理研究所);Marietta-Blau-Institut für Teilchenphysik(玛丽塔·布劳粒子物理研究所);Atominstitut, Technische Universität Wien(维也纳工业大学原子研究所);INFN - Sezione di Roma(意大利国家核物理研究所罗马分部);Gran Sasso Science Institute(格兰萨索科学研究所);INFN - Laboratori Nazionali del Gran Sasso(意大利国家核物理研究所格兰萨索国家实验室)
Development of a dedicated beam forming system for material and bioscience research with high intensity, small field electron beam of LILLYPUT 3 accelerator at Wroclaw Technology Park