We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with $^{88}$Sr$^+$ ions using laser ablation, which is compatible with the cryogenic environment. Using Doppler cooling we observed small ion crystals in which optically resolved ions have a trapped lifetime over 2500 minutes.
We describe the design, commissioning and operation of an ultra-low-vibration closed-cycle cryogenic ion trap apparatus. One hundred lines for low-frequency signals and eight microwave / radio frequency coaxial feed lines offer the possibility of implementing a small-scale ion-trap quantum processor or simulator. With all supply cables attached, more than 1.3 W of cooling power at 5 K is still available for absorbing energy from electrical pulses introduced to control ions. The trap itself is isolated from vibrations induced by the cold head using a helium exchange gas interface. The performan…
Cryogenic semiconductor detectors operated at temperatures below 100 mK are commonly used in particle physics experiments searching for dark matter. The largest such germanium and silicon detectors, with diameters of 100 mm and thickness of 33 mm, are planned for use by the Super Cryogenic Dark Matter Search (SuperCDMS) experiment at SNOLAB, Canada. In order to scale up the sensitive mass of future experiments, larger individual detectors are being investigated. We present here the first results of testing two prototype 150 mm diameter silicon ionization detectors. The detectors are 25 mm and …
We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access, and enables rapid turnaround and flexiblity for future modifications. Long rectangular windows provide nearly 360 degrees of optical access in the plane of the ion trap, while a circular bottom window near the trap enables NA 0.4 light collection without the need for in-vacuum optics. We evaluate the system's mechanical and thermal characteris…
Trapping ions in Paul traps requires high radio-frequency voltages, which are generated using resonators. When operating traps in a cryogenic environment, an in-vacuum resonator showing low loss is crucial to limit the thermal load to the cryostat. In this study, we present a guide for the design and production of compact, shielded cryogenic resonators. We produced and characterized three different types of resonators and furthermore demonstrate efficient impedance matching of these resonators at cryogenic temperatures.
We have successfully demonstrated an integrated optical system for collecting the fluorescence from a trapped ion. The system, consisting of an array of transmissive, dielectric micro-optics and an optical fiber array, has been intimately incorporated into the ion-trapping chip without negatively impacting trapping performance. Epoxies, vacuum feedthrough, and optical component materials were carefully chosen so that they did not degrade the vacuum environment, and we have demonstrated light detection as well as ion trapping and shuttling behavior comparable to trapping chips without integrate…
In this paper we present the design, modeling, and experimental testing of surface electrode ion traps fabricated in a heterostructure configuration comprising a silicon substrate, silicon dioxide insulators, and aluminum electrodes. This linear trap has a geometry with symmetric RF leads, two interior DC electrodes, and 40 individual lateral DC electrodes. Plasma enhanced chemical vapor deposition (PECVD) was used to grow silicon dioxide pillars to electrically separate overhung aluminum electrodes from an aluminum ground plane. In addition to fabrication, we report techniques for modeling th…
We have developed an trapped ion system for producing two-dimensional (2D) ion crystals for applications in scalable quantum computing, quantum simulations, and 2D crystal phase transition and defect studies. The trap is a modification of a Paul trap with its ring electrode flattened and split into eight identical sectors, and its two endcap electrodes shaped as truncated hollow cones for laser and imaging optics access. All ten trap electrodes can be independently DC-biased to create various aspect ratio trap geometries. We trap and Doppler cool 2D crystals of up to 30 Ba+ ions and demonstrat…
Discharge quenching mechanism and performance of RPWELL with tunable 3D printed resistive plates, charge evacuation in semiconductive glass RPWELL and discharge quenching for Cryogenic-RWELL over a wide range of resistivity
Despite the progress in building sophisticated microfabricated ion traps, Paul traps employing needle electrodes retain their significance due to the simplicity of fabrication while producing high-quality systems suitable for quantum information processing, atomic clocks etc. For low noise operations such as minimizing `excess micromotion', needles should be geometrically straight and aligned precisely with respect to each other. Self-terminated electrochemical etching, previously employed for fabricating ion trap needle electrodes employs a sensitive and time-consuming technique resulting in …
The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\mathrm{V/cm}$), and as a consequence charge-carrier trapping significantly affects both the ionization and heat energy measurements. This paper describes an analytical model of the signals induced by trapped charges in FID detectors based on the Shockley-Ramo theorem. It is used to demonstrate that veto electrodes, initially designed for the sole purpose of surface event rejection, can be used to provide a sensitivity …
Cryogenic source of atomic tritium for neutrino-mass measurements and precision spectroscopy
University of Turku(图尔库大学);Sorbonne Université(索邦大学);ENS-PSL Université(巴黎文理研究大学);Collège de France(法兰西公学院);Institut Max von Laue - Paul Langevin(马克斯·冯·劳厄-保罗·朗之万研究所);Marietta Blau Institute for Particle Physics, Austrian Academy of Sciences(奥地利科学院玛丽亚·布劳粒子物理研究所);Institute for Particle Physics and Astrophysics, ETH(苏黎世联邦理工学院粒子物理与天体物理研究所);Institute for Astroparticle Physics (IAP), Karlsruhe Institute of Technology (KIT)(卡尔斯鲁厄理工学院亚原子物理研究所)
The use of electrostatic ion beam traps require to set many potentials on the electrodes (ten in our case), making the tuning much more difficult than with quadrupole traps. In order to obtain the best trapping conditions, an analytical formula giving the electrostatic potential inside the trap is required. In this paper, we present a general method to calculate the analytical expression of the electrostatic potential in any axisymmetric set of electrodes. We use conformal mapping to simplify the geometry of the boundary. The calculation is then performed in a space of simple geometry. We show…
The advent of microfabricated ion traps for the quantum information community has allowed research groups to build traps that incorporate an unprecedented number of trapping zones. However, as device complexity has grown, the number of digital-to-analog converter (DAC) channels needed to control these devices has grown as well, with some of the largest trap assemblies now requiring nearly one hundred DAC channels. Providing electrical connections for these channels into a vacuum chamber can be bulky and difficult to scale beyond the current numbers of trap electrodes. This paper reports on the…
We present the design of a compact optical clock based on the $^2S_{1/2} \rightarrow ^2D_{3/2}$ 435.5 nm transition in $^{171}$Yb$^+$. The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred $μ$m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm need…