arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2107.09398physics.ins-dethep-ex
收藏

PandaX-4T低温精馏除氪系统的实验分析

Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon

Rui Yan, Zhou Wang, Xiangyi Cui, Yonglin Ju, Haidong Sha, Shuaijie Li, Peiyao Huang, Xiuli Wang, Wenbo Ma, Yingjie Fan, Xiangdong Ji, Jifang Zhou, Changsong Shang, Liqiang Liu

摘要:

基于McCabe-Thiele(M-T)方法和质量、能量守恒原理,为PandaX-4 T暗物质探测器设计并搭建了一套高效的低温蒸馏系统。该蒸馏系统设计用于将市售氙气中的氪浓度从5 × $10^{-7}$ mol/mol降低至$10^{-14}$ mol/mol,在最大流速为10 kg/h时,氙气收集效率为99%。已完成离线蒸馏操作,生产出5.75吨超高纯氙气,用作PandaX-4 T探测器中的探测介质。测量产物氙的氪浓度,上限为8.0 ppt。通过对实验数据的分析,研究了低温精馏系统的稳定性和净化性能,对理论研究和精馏操作优化具有重要意义。

英文摘要:

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the concentration of krypton in commercial xenon from 5X$10^{-7}$ mol/mol to $10^{-14}$ mol/mol with 99% xenon collection efficiency at a maximum flow rate of 10 kg/h. The offline distillation operation has been completed and 5.75 tons of ultra-high purity xenon was produced, which is used as the detection medium in PandaX-4T detector. The krypton concentration of the product xenon is measured with an upper limit of 8.0 ppt. The stability and purification performance of the cryogenic distillation system are studied by analyzing the experimental data, which is important for theoretical research and distillation operation optimization.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑