arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2403.04239physics.ins-dethep-ex
收藏

PandaX-4T中的信号响应模型

Signal Response Model in PandaX-4T

Yunyang Luo, Zihao Bo, Shibo Zhang, Abdusalam Abdukerim, Chen Cheng, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Chan… 展开作者

Yunyang Luo, Zihao Bo, Shibo Zhang, Abdusalam Abdukerim, Chen Cheng, Wei Chen, Xun Chen, Yunhua Chen, Zhaokan Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Chencheng Han, Ke Han, Changda He, Jinrong He, Di Huang, Yanlin Huang, Zhou Huang, Ruquan Hou, Xiangdong Ji, Yonglin Ju, Chenxiang Li, Jiafu Li, Mingchuan Li, Shu Li, Shuaijie Li, Qing Lin, Jianglai Liu, Xiaoying Lu, Lingyin Luo, Wenbo Ma, Yugang Ma, Yajun Mao, Nasir Shaheed, Yue Meng, Xuyang Ning, Ningchun Qi, Zhicheng Qian, Xiangxiang Ren, Changsong Shang, Xiaofeng Shang, Guofang Shen, Lin Si, Wenliang Sun, Andi Tan, Yi Tao, Anqing Wang, Meng Wang, Qiuhong Wang, Shaobo Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wang, Yuehuan Wei, Mengmeng Wu, Weihao Wu, Jingkai Xia, Mengjiao Xiao, Xiang Xiao, Pengwei Xie, Binbin Yan, Xiyu Yan, Jijun Yang, Yong Yang, Chunxu Yu, Jumin Yuan, Ying Yuan, Zhe Yuan, Xinning Zeng, Dan Zhang, Minzhen Zhang, Peng Zhang, Shu Zhang, Tao Zhang, Yingxin Zhang, Yuanyuan Zhang, Li Zhao, Qibin Zheng, Jifang Zhou, Ning Zhou, Xiaopeng Zhou, Yong Zhou, Yubo Zhou

AI总结:

本文系统构建并拟合了PandaX-4T暗物质探测器的信号响应模型,覆盖电子反冲与核反冲关键能区,并整合信号重建、选择与修正方法,为数据解释提供关键支撑。

摘要:

PandaX-4T实验是一个深地下的暗物质直接探测实验,采用双相时间投影室,其灵敏体积包含3.7吨液氙。PandaX-4T探测器能够同时收集初级闪烁信号和电离信号,并利用二者的比值来区分暗物质信号与伽马射线、贝塔粒子等本底源。信号响应模型在解释PandaX-4T所获数据中起着关键作用,它描述了从暗物质相互作用沉积能量到探测器内可探测信号的转换过程。该信号响应模型已被用于多项PandaX-4T物理结果。本工作全面描述了信号响应模型的构建与参数拟合流程,覆盖电子反冲约1 keV至25 keV以及核反冲6 keV至90 keV的能量范围。文中还介绍了信号重建、选择与修正方法,这些方法是集成到信号响应模型中的关键组成部分。

英文摘要:

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of simultaneously collecting the primary scintillation and ionization signals, utilizing their ratio to discriminate dark matter signals from background sources such as gamma rays and beta particles. The signal response model plays a crucial role in interpreting the data obtained by PandaX-4T. It describes the conversion from the deposited energy by dark matter interactions to the detectable signals within the detector. The signal response model is utilized in various PandaX-4T results. This work provides a comprehensive description of the procedures involved in constructing and parameter-fitting the signal response model for the energy range of approximately 1 keV to 25 keV for electronic recoils and 6 keV to 90 keV for nuclear recoils. It also covers the signal reconstruction, selection, and correction methods, which are crucial components integrated into the signal response model.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑