arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2006.09311physics.ins-dethep-exnucl-ex
收藏

用氡气体源对PandaX-II探测器进行内标

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

Wenbo Ma, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Ge… 展开作者

Wenbo Ma, Abdusalam Abdukerim, Zihao Bo, Wei Chen, Xun Chen, Yunhua Chen, Chen Cheng, Xiangyi Cui, Yingjie Fan, Deqing Fang, Changbo Fu, Mengting Fu, Lisheng Geng, Karl Giboni, Linhui Gu, Xuyuan Guo, Ke Han, Changda He, Shengming He, Di Huang, Yan Huang, Yanlin Huang, Zhou Huang, Xiangdong Ji, Yonglin Ju, Shuaijie Li, Huaxuan Liu, Jianglai Liu, Yugang Ma, Yajun Mao, Yue Meng, Kaixiang Ni, Jinhua Ning, Xuyang Ning, Xiangxiang Ren, Changsong Shang, Lin Si, Guofang Shen, Andi Tan, Anqing Wang, Hongwei Wang, Meng Wang, Qiuhong Wang, Siguang Wang, Wei Wang, Xiuli Wang, Zhou Wang, Mengmeng Wu, Shiyong Wu, Weihao Wu, Jingkai Xia, Mengjiao Xiao, Pengwei Xie, Binbin Yan, Jijun Yang, Yong Yang, Chunxu Yu, Jumin Yuan, Ying Yuan, Jianfeng Yue, Xinning Zeng, Dan Zhang, Tao Zhang, Li Zhao, Qibin Zheng, Jifang Zhou, Ning Zhou, Xiaopeng Zhou

摘要:

我们发展了一种用$^{220}$ Rn标定PandaX-Ⅱ探测器低能电子反冲(ER)的方法。天然钍化合物释放出的$^{220}$ Rn通过氙净化系统进入探测器。从2017年到2019年,我们进行了三次不同氡源的专门校准活动。我们研究了探测器对$α$、$β$和$γ$粒子的响应,重点是低能ER事件。在2017年和2018年的运行期间,$^{222}$ Rn的放射性量约为$^{220}$ Rn的1\%,钍颗粒污染可忽略不计,尤其是在2018年。在PandaX-II中,我们还在$^{222}$ Rn注入的帮助下首次测量了$^{214}$ Pb的背景贡献。使用$^{220}$ Rn和$^{222}$ Rn的校准策略将在即将到来的PandaX-4 T实验中实施,并且也可以用于其他氙基探测器。

英文摘要:

We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑