arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2312.07720physics.ins-det
收藏

用于气态暗物质和稀有事件探测器的分子筛真空变压吸附纯化及降氡系统

Molecular sieve vacuum swing adsorption purification and radon reduction system for gaseous dark matter and rare-event detectors

R. R. Marcelo Gregorio, N. J. C. Spooner, F. Dastgiri, A. C. Ezeribe, G. Lane, A. G. McLean, K. Miuchi, H. Ogawa

AI总结:

本研究针对暗物质实验靶气体SF6的杂质去除难题,研发出基于低放射性5A分子筛的真空变压吸附循环系统,可同时降氡和去除常见污染物,显著降低探测器本底并缓解增益劣化。

摘要:

在定向暗物质实验领域,SF6已成为一种理想的靶气体。这种气体以及其他拟用气体面临的一项关键挑战是杂质气体的有效去除。这些杂质既包括会产生不必要本底事件的氡,也包括水、氧气和氮气等常见污染物——这类污染物会俘获电离电子,导致探测器气体增益随时间下降。本文提出了一种新型基于分子筛(MS)的气体循环系统,可同时去除SF6中的氡和常见污染物。该装置的额外优势是能最大程度减少实验所需的气体量,并采用真空变压吸附(VSA)技术实现连续、长期运行。研究人员使用一台100升低压SF6时间投影室(TPC)探测器测试了该气体系统的性能。本文首次展示了一种新研发的低放射性5A型分子筛。经测定,与市售同类产品相比,该材料每俘获一个氡原子的氡析出量低98%,是撰写本文时已知的最低分子筛氡析出水平。相应地,TPC探测器中的氡活度得以降低,在95%置信水平(C.L.)下其上限小于7.2 mBq。研究还发现,加入3A型和4A型分子筛来吸收常见污染物,可在循环靶气体的同时成功缓解增益劣化问题。

英文摘要:

In the field of directional dark matter experiments, SF6 has emerged as an ideal target gas. A critical challenge with this gas, and with other proposed gases, is the effective removal of contaminant gases. This includes radon which produce unwanted background events, but also common pollutants such as water, oxygen, and nitrogen, which can capture ionisation electrons, resulting in loss of detector gas gain over time. We present here a novel molecular sieve (MS) based gas recycling system for the simultaneous removal of both radon and common pollutants from SF6. The apparatus has the additional benefit of minimising gas required in experiments and utilises a Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation. The gas system's capabilities were tested with a 100 L low-pressure SF6 Time Projection Chamber (TPC) detector. For the first time, we present a newly developed low-radioactive MS type 5A. This material was found to emanate radon at 98% less per radon captured compared to commercial counterparts, the lowest known MS emanation at the time of writing. Consequently, the radon activity in the TPC detector was reduced, with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.). Incorporation of MS types 3A and 4A to absorb common pollutants was found successfully to mitigate against gain deterioration while recycling the target gas.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑