arXivDaily arXiv每日学术速递 周一至周五更新
arXiv周末暂无论文更新,休息一下吧,周末愉快~~
arXiv 2511.03250physics.ins-dethep-ex
收藏

一种用于抑制外部氡本底的气密性气态氙探测器的研制

Development of a Hermetic Gaseous Xenon Detector for Suppressing External Radon Background

Ryuta Miyata, Koki Fujikawa, Rina Harata, Yoshitaka Itow, Shingo Kazama, Masatoshi Kobayashi

AI总结:

本文研制了一种采用法兰与ePTFE垫圈机械密封的气密性气态氙探测器,通过670小时氡注入实验验证其对氡泄漏的抑制能力,并外推证明该方案足以满足大型液氙暗物质实验对氡本底控制的要求。

摘要:

氡引起的本底,特别是来自$^{222}$Rn及其β发射子体的本底,对下一代旨在将暗物质探测推进到中微子雾的液氙(LXe)探测器构成了关键挑战。为解决这一问题,我们研制了一种紧凑型气密性气态氙(GXe)探测器。该装置通过使用一个密封在两个石英法兰之间的PTFE容器,并采用机械压缩的ePTFE垫圈,将灵敏体积与外部氡源物理隔离。为量化氡密封性能,我们搭建了一套双回路GXe循环系统,并开展了长达670小时的氡注入测量实验。利用静电氡探测器和光电倍增管(PMTs)对进入气密探测器的氡进行了监测。基于这两项独立测量,气密探测器内部与外部氡浓度的稳态比值分别估计为$(1.1 \pm 0.1) \times 10^{-2}$和$(1.1 \pm 0.2) \times 10^{-2}$,对应的氡泄漏流量分别为$(2.9 \pm 0.3) \times 10^{-11}$和$(2.6 \pm 0.4) \times 10^{-11}$ $\thinspace$m$^{3}$ $\thinspace$ $\mathrm{s}^{-1}$。将结果外推至如XLZD这样的60吨级LXe时间投影室(TPC),表明氡泄漏量可能仅为$1.2 \times 10^{-2}$ $\thinspace$mBq,与探测器内部预期的天然氡析出(通常为3$\thinspace$mBq)相比可以忽略不计。这些结果表明,基于法兰的机械密封为在大规模LXe实验中实现氡隔离的内部探测器提供了一种有效解决方案。

英文摘要:

Radon-induced backgrounds, particularly from $^{222}$Rn and its beta-emitting progeny, present a critical challenge for next-generation liquid xenon (LXe) detectors aimed at probing dark matter down to the neutrino fog. To address this, we developed a compact hermetic gaseous xenon (GXe) detector. This device physically isolates the active volume from external radon sources by using a PTFE vessel sealed between two quartz flanges with mechanically compressed ePTFE gaskets. To quantify radon sealing performance, we implemented a dual-loop GXe circulation system and conducted a 670-hour radon-injection measurement campaign. Radon ingress into the hermetic detector was monitored using electrostatic radon detectors and photomultiplier tubes (PMTs). From these two independent measurements, the steady-state ratios of the radon concentrations inside the hermetic detector to those outside were estimated to be $ (1.1 \pm 0.1) \times 10^{-2} $ and $ (1.1 \pm 0.2) \times 10^{-2} $, corresponding to radon-leakage flows of $ (2.9 \pm 0.3) \times 10^{-11} $ and $ (2.6 \pm 0.4) \times 10^{-11} $ $ \thinspace $m$^{3}$ $ \thinspace $ $\mathrm{s}^{-1}$, respectively. An extrapolation to a 60-tonne LXe TPC such as XLZD suggests that the radon leakage could amount to $ 1.2 \times 10^{-2} $ $ \thinspace $mBq, which is negligible compared to the expected natural radon emanation inside the detector, typically 3$ \thinspace $mBq. These results demonstrate that flange-based mechanical sealing provides an effective solution for realizing radon-isolated inner detectors in large-scale LXe experiments.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑