arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 1611.03585physics.ins-det
收藏

用溶解氡-220源校准XENON100的结果

Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220

The XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benab… 展开作者

The XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Butikofer, J. Calven, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre, A. P. Colijn, J. Conrad, J. P. Cussonneau, M. P. Decowski, P. dePerio, P. DiGangi, A. DiGiovanni, S. Diglio, E. Duchovni, G. Eurin, J. Fei, A. D. Ferella, A. Fieguth, D. Franco, W. Fulgione, A. Gallo Rosso, M. Galloway, F. Gao, M. Garbini, C. Geis, L. W. Goetzke, L. Grandi, Z. Greene, C. Grignon, C. Hasterok, E. Hogenbirk, R. Itay, B. Kaminsky, G. Kessler, A. Kish, H. Landsman, R. F. Lang, D. Lellouch, L. Levinson, M. LeCalloch, Q. Lin, S. Lindemann, M. Lindner, J. A. M. Lopes, A. Manfredini, I. Maris, T. Marrodan Undagoitia, J. Masbou, F. V. Massoli, D. Masson, D. Mayani, Y. Meng, M. Messina, K. Micheneau, B. Miguez, A. Molinario, M. Murra, J. Naganoma, K. Ni, U. Oberlack, S. E. A. Orrigo, P. Pakarha, B. Pelssers, R. Persiani, F. Piastra, J. Pienaar, M. -C. Piro, G. P lante, N. Priel, L. Rauch, S. Reichard, C. Reuter, A. Rizzo, S. Rosendahl, N. Rupp, R. Saldanha, J. M. F. dosSantos, G. Sartorelli, M. Scheibelhut, S. Schindler, J. Schreiner, M. Schumann, L. Scotto Lavina, M. Selvi, P. Shagin, E. Shockley, M. Silva, H. Simgen, M. v. Sivers, A. Stein, D. Thers, A. Tiseni, G. Trinchero, C. Tunnell, N. Upole, H. Wang, Y. Wei, C. Weinheimer, J. Wulf, J. Ye, Y. Zhang

摘要:

为了解决吨级液体稀有元素探测器的校准问题,在XENON 100暗物质探测器上安装了一个Rn-220源。我们表明,Pb-212 β发射可用于低能量电子反冲校准在寻找暗物质。这种同位素散布在探测器的整个活动区域,其活动在源关闭后一周内自然衰减到本底水平以下。我们发现校准后,麻烦的Rn-222背景的活性没有增加。α发射体也分布在整个探测器中,便于校准其对Rn-222的响应。利用Rn-220/Po-216的延迟符合,我们首次在XENON 100探测器中绘制了粒子的对流运动。此外,我们对Po-212的半衰期进行了竞争性测量,t = 293.9 ±(1.0)±(0.6)ns。

英文摘要:

A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below background level within a week after the source is closed. We find no increase in the activity of the troublesome Rn-222 background after calibration. Alpha emitters are also distributed throughout the detector and facilitate calibration of its response to Rn-222. Using the delayed coincidence of Rn-220/Po-216, we map for the first time the convective motion of particles in the XENON100 detector. Additionally, we make a competitive measurement of the half-life of Po-212, t = 293.9+-(1.0)+-(0.6) ns.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑