The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.
We describe the electronics and data acquisition system used in the first phase of the PandaX experiment -- a 120 kg dual-phase liquid xenon dark matter direct detection experiment in the China Jin-Ping Underground Laboratory. This system utilized 180 channels of commercial flash ADC waveform digitizers. This system achieved low trigger threshold ($<$1 keV electron-equivalent energy) and low deadtime data acquistion during the entire experimental run.
We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-phase xenon dark matter experiment. This is the first time that a significant number of R11410 photomultiplier tubes were operated in liquid xenon for an extended period, providing important guidance to the future large xenon-based dark matter experiments.
PandaX-II experiment is a dark matter direct detection experiment using about half-ton of liquid xenon as the sensitive target. The electrical pulses detected by photomultiplier tubes from scintillation photons of xenon are recorded by waveform digitizers. The data acquisition of Pandax-II relies on a trigger system that generates common trigger signals for all waveform digitizers. Previously an analog device-based trigger system was used for the data acquisition system. In this paper we present a new FPGA-based trigger system. The design of this system and trigger algorithms are described. Th…
PandaX-4T, the new generation of the PandaX detector, is a xenon dual-phase detector with about six tons of liquid xenon as target for dark matter search. A cryogenics and xenon handling system is designed to liquify and purify this large detector. In this paper, the results on the commission of the cryogenics and gas handling system are reported. The maximum cooling power of ~ 580 W at 178 K with three cooperating coldheads has been achieved. The filling rate with an assisted liquid nitrogen cooling can reach ~ 700 kg/day. The average rate of recuperation by liquid nitrogen is around 440 kg/d…
We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limi…
We report a systematic determination of the responses of PandaX-II, a dual phase xenon time projection chamber detector, to low energy recoils. The electron recoil (ER) and nuclear recoil (NR) responses are calibrated, respectively, with injected tritiated methane or $^{220}$Rn source, and with $^{241}$Am-Be neutron source, within an energy range from $1-25$ keV (ER) and $4-80$ keV (NR), under the two drift fields of 400 and 317 V/cm. An empirical model is used to fit the light yield and charge yield for both types of recoils. The best fit models can well describe the calibration data. The sys…
PandaX-4T is a dark matter direct detection experiment located in China jinping underground laboratory. The central apparatus is a dual-phase xenon detector containing 4 ton liquid xenon in the sensitive volume, with about 500 photomultipliers instrumented in the top and the bottom of the detector. In this paper we present a completely new system of readout electronics and data acquisition in the PandaX-4T experiment. Compared to the one used in the previous PandaX dark matter experiments, the new system features triggerless readout and higher bandwidth. With triggerless readout, dark matter s…
Design, construction, and testing of the PandaX-xT cryogenics system
Shanghai Jiao Tong University(上海交通大学);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Sun Yat-Sen University(中山大学);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to transport heat loads to a free-boiling liquid nitrogen bath. The performance of the test module and commercial refrigerators is compared. The module with an optimized copper rod has demonstrated more than 1500W cooling power at 178K.The temperature of the "cold head" can be kept stable with an error of 0.02K, its fluctuation is within 0.1K.
The PandaX project consists of a series of xenon-based experiments that are used to search for dark matter (DM) particles and to study the fundamental properties of neutrinos. The next DM experiment PandaX-4T will be using 4 ton liquid xenon in the sensitive volume, which is nearly a factor of seven larger than that of the previous experiment PandaX-II. Due to the increasing target mass, the sensitivity of searching for both DM and neutrinoless double-beta decay ($0νββ$) signals in the same detector will be significantly improved. However, the typical energy of interest for $0νββ$ signals is a…
Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent resul…
We discuss an in-situ evaluation of the $^{85}$Kr, $^{222}$Rn, and $^{220}$Rn background in PandaX-I, a 120-kg liquid xenon dark matter direct detection experiment. Combining with a simulation, their contributions to the low energy electron-recoil background in the dark matter search region are obtained.
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operates in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120\,kg. In stage II, the target mass will be increased to about 0.5\,ton. In the final stage, the detector can…
The throttling refrigeration system for high cooling power recovery of the PandaX-xT cryogenic distillation system for radon removal
SJTU Paris Elite Institute of Technology, Shanghai Jiao Tong University(上海交通大学巴黎卓越工程师学院);New Cornerstone Science Laboratory, Tsung-Dao Lee Institute, Shanghai Jiao Tong University(新Cornerstone科学实验室,汤川秀树研究所,上海交通大学);School of Physics and Astronomy, Shanghai Jiao Tong University(上海交通大学物理与天文学院);Shanghai Jiao Tong University Sichuan Research Institute(上海交通大学四川研究院);Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province(四川省锦屏深地下前沿科学与暗物质重点实验室);Vacree Technologies Co., Ltd.(沃瑞科技有限公司);School of Chemical Engineering, Zhengzhou University(郑州大学化学工程与应用学院);School of Physics, Sun Yat-Sen University(中山大学物理学院);Department of Physics, University of Maryland, College Park(马里兰大学帕克分校物理系);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司)
We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP …
The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fi…
Results of WIMP dark matter search from the first data of the PandaX-II experiment are presented. PandaX-II experiment uses a 500 kg scale dual phase liquid xenon time projection chamber, operating at the China JinPing Underground Laboratory. The first data correspond to a total exposure of $3.1\times10^{4}$ kg-day. The observed data after selections are found to be consistent with background expection, and upper limits of the spin-independent WIMP-nucleon cross sections are derived for a range of WIMP mass between 5 GeV/c$^2$ and 1000 GeV/$c^{2}$. The lowest cross section limit obtained is 2.…
In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and developed. This system includes a diaphragm pump, the heat management system, the main recuperation pipeline, the reflux pipeline, the auxiliary recuperation pipeline and the automatic control system. The liquid xenon in the detector is vaporized by the heat management system, and the gaseous xenon is compressed to 6 MPa at the flow rate of 200 standard litres p…
We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross sectio…
The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark ma…
We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.
Dual-phase noble-gas time projection chambers (TPCs) have improved the sensitivities for dark matter direct search in past decades. The capability of TPCs to reconstruct 3-D vertexes of keV scale recoilings is one of the most advantageous features. In this work, we develop two horizontal position reconstruction algorithms for the PandaX-II dark matter search experiment using the dual-phase liquid xenon TPC. Both algorithms are optimized by the $^{83m}$Kr calibration events and use photon distribution of ionization signals among photomultiplier tubes to infer the positions. According to the eve…
We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,…
Capacitive devices are customarily used as probes to measure the level of noble liquids in detectors operated for neutrino studies and dark matter searches. In this work we describe the use of a high-temperature superconducting material as an alternative to control the level of a cryogenic noble liquid. Lab measurements indicate that the superconductor shows a linear behaviour, a high degree of stability and offers a very accurate determination of the liquid volume. This device is therefore a competitive instrument and shows several advantages over conventional level meters.
A study of the dynamics of the positive charges in liquid argon has been carried out in the context of the future massive time projection chambers proposed for dark matter and neutrino physics. Given their small mobility coefficient in liquid argon, the ions spend a considerably longer time in the active volume with respect to the electrons. The positive charge density can be additionally increased by the injection, in the liquid volume, of the ions produced by the electron multiplying devices located in gas argon. The impact of the ion current on the uniformity of the field has been evaluated…
In recent years cooling technology for Liquid Xenon (LXe) detectors has advanced driven by the development of Dark Matter (DM) detectors with target mass in the 100 - 1,000 kg range. The next generation of DM detectors based on LXe will be in the 50,000 kg (50 t) range requiring more than 1 kW of cooling power. Most of the prior cooling methods become impractical at this level. For cooling a 50 t scale LXe detector, a method is proposed in which Liquid Nitrogen (LN$_2$) in a small local reservoir cools the xenon gas via a cold finger. The cold finger incorporates a heating unit to provide temp…
An optical link system is being developed for the ATLAS Liquid Argon Calorimeter Phase-II upgrade. The optical link system is responsible for transmit the data of over 182 thousand detector channels from 1524 Front-End Boards (FEBs) through 26 optical fibers per FEB over 150 meters to the counting room and brings clocks, bunch crossing reset signals and slow control/monitoring signals back to the FEBs. The optical link system is based on the Low-Power GigaBit Transceivers (lpGBTs) and the Versatile optical Transceiver (VTRx+) modules, which both are being developed for the High-Luminosity LHC …
$\rm ^{83m}Kr$, with a short lifetime, is an ideal calibration source for liquid xenon or liquid argon detectors. The $\rm ^{83m}Kr$ isomer can be generated through the decay of $\rm ^{83} Rb$ isotope which is usually produced by proton beams bombarding natural krypton atoms. In this paper, we report a successful production of $\rm ^{83}Rb/^{83m}Kr$ with a proton beam energy of 3.4 MeV, and the first measurement of the production rate with such low energy proton beams. Another production attempt is performed using the newly available 20 MeV proton beam in China, and the measured production rat…
We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon and monitor the light yield from an alpha source. The source is placed at different distances from a cryogenic photomultiplier tube assembly. By comparing the light yield from each position we extract the absorption cross section of nitrogen. We find that nitrogen absorbs argon scintillation light with strength of $(1.51\pm 0.15)\times10^{-4} \;\mathrm{cm^{-…
We present the results of FLUKA simulations of the propagation of cosmogenic muons in a 20 kton spherical liquid scintillator detector underneath 700 to 900 meters of rock. A showering muon is one which deposits at least 3 GeV in the detector in addition to ionization energy. We find that 20 percent of muons are showering and a further 10 percent of muon events are muon bundles of which more than one muon enters the detector. In this range the showering and bundle fractions are robust against changes in the depth and topography, thus the total shower and bundle rate for a given experiment can …
In this study, the conceptual design and physics simulations of a near-field Water-based Liquid Scintillator (WbLS) detector placed 100 meters from the Akkuyu Nuclear Power Plant (ANPP), currently under construction and aiming at being Turkey's first nuclear power plant, is presented. The ANPP is an excellent opportunity for neutrino studies and the development of an R&D program for neutrino detectors in Turkey. The Reactor Neutrino Experiments of Turkey (RNET) program includes a compact and portable detector with a 2.5-ton volume of WbLS and a ~30% photo-coverage, and the program is planned t…
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high pressure xenon time projection chamber (HPXe-TPC) has two advantages over liquid xenon TPCs: a better energy resolution and the access to topological features, which may provide extra discrimination from background events. The PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on Micromegas readout planes, to be located at the Jinping Underground Laboratory in China. Its detection concept is based on two results obtained within the T-REX project: Micromegas readouts can be built with extremely low level…
Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding one meter, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a five-liter, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. In this work, we present the ma…
Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., $β$, $α$) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged part…
A technique using layered wavelength shifting, scintillating and non-scintillating films is presented to achieve discrimination of surface $α$ events from low-energy nuclear recoils in liquid argon detectors. A discrimination power greater than $10^{8}$, similar to the discrimination possible for electronic recoils in argon, can be achieved by adding a 50 micron layer of scintillator with a suitably slow decay time, approximately 300 ns or greater, to a wavelength-shifter coated surface. The technique would allow suppression of surface $α$ events in a very large next-generation argon dark matt…
Muon tomography (MT), based on atmospheric cosmic rays, is a promising technique suitable for nondestructive imaging of the internal structures of mountains. This method uses the measured flux distribution after attenuation, combined with the known muon angular and energy distributions and a 3D satellite map, to perform tomographic imaging of the density distribution inside a probed volume. A muon tomography station (MTS) requires direction-sensitive detectors with a high resolution for optimal tracking of incident cosmic-ray muons. The spherical liquid scintillator detector is one of the best…
In order to carry out research in the field of possible existence of a sterile neutrino the laboratory based on SM-3 reactor (Dimitrovgrad, Russia) was created to search for oscillations of reactor antineutrino. The prototype of a multi-section neutrino detector with liquid scintillator volume of 350 l was installed in the middle of 2015. It is a moveable inside the passive shielding detector, which can be set at distance range from 6 to 11 meters from the reactor core. Measurements of antineutrino flux at such short distances from the reactor core are carried out with moveable detector for th…
Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensi…
This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($ν_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $ν_s$'s and LDM resulting from $π^+$ and $π^0$ decays in the tungsten target. …