In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector, and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in nondestructive assay for nuclear safeguards, and explore trends in performance vs.\ parameters such as clustering algorithm type. We also compare the NMF+clustering pipeline to several non-machine-learning algorithms, including several greedy algorithms. Overall, we find that the NMF+clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the un-optimized spectra, but that a greedy accumulation of spectra segmented by detector depth can in some cases give similar performance improvements in much less computation time.
A multi-stop time-of-flight spectrometer for the measurement of positron annihilation-induced electrons in coincidence with the Doppler-shifted annihilation gamma photon
Monte Carlo analysis of the contributions of long-lived positronium to the spectra of positron-impact-induced secondary electrons measured using an annihilation-gamma-triggered time-of-flight spectrometer
Gamma Imagers for Nuclear Security and Nuclear Forensics: Recommendations based on results from a side-by-side intercomparison
Natural Resources Canada(加拿大自然资源部);National Research Council Canada(加拿大国家研究委员会);Carleton University(卡尔顿大学);Canadian Nuclear Safety Commission(加拿大核安全委员会);Defence Research and Development Canada(加拿大国防研发局)
Gamma-induced background in the KATRIN main spectrometer
KATRIN实验的目的是测量有效电子反中微子质量$m_{\overlineν_e}$,灵敏度为0.2 eV/c $^2$,使用气态氚源结合MAC-E过滤技术。低背景速率对于实现所提出的灵敏度是至关重要的,并且已经进行了专门的测量以研究背景电子的可能来源。在这项工作中,我们测试的假设,从外部放射性源的伽马辐射显着增加了在主光谱仪(MS)中创建的背景事件,并在焦平面探测器中观察到的速率。使用实验大厅中伽马通量的详细模拟,结合一系列人为增加或减少到MS的局部伽马通量的实验测试,我们将上限设定为0.006计数/秒(90% C. L.)从这个机制。我们的研究结果表明,用于阻止从MS的内表面发射的次级电子的静电和磁屏蔽的有效性。
Data-driven optimization of pixelated CdZnTe spectrometers for uranium enrichment assay
Nuclear Science Division, Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室核科学部);National Security Directorate, Pacific Northwest National Laboratory(太平洋西北国家国家安全局)
Inter-detector differential fuzz testing for tamper detection in gamma spectrometers
Nuclear Science Division, Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室核科学部);Computing Sciences Research, Lawrence Berkeley National Laboratory(劳伦斯伯克利国家实验室计算科学研究);Computer Science and Public Health Departments, University of California, Davis(加州大学戴维斯分校计算机科学与公共卫生学院)
Characterisation and calibration of a scintillating fibre detector with > 4000 multi-anode photomultiplier channels
在美因茨的Kaos光谱仪中,运行着一个高分辨率的高能粒子坐标探测器。它由直径为4000个< 1mm and is read out by >多阳极光电倍增管通道的增强纤维组成。它是世界上最先进的磁谱仪焦平面探测器之一。为了校正由不同的增益和不同的光学透射率引起的检测效率的变化,已经开发了全自动离线校准程序。该过程包括将放射性同位素源定位在探测器平面旁边以及自动采集和分析探测器信号。可以通过低程度的人工交互来校准和校准每个单独的光纤通道。