arXiv 1608.01109physics.ins-det
收藏

水下原位LaBr3:Ce谱仪的能量自定标和效率定标优化

Optimization of an underwater in-situ LaBr3:Ce spectrometer with energy self-calibration and efficiency calibration

Zhi Zeng, Xingyu Pan, Hao Ma, Jianhua He, Jirong Cang, Ming Zeng, Yuhao Mi, Jianping Cheng

摘要:

研制并优化了一种用于海洋放射性监测的LaBr3水下原位γ能谱仪。采用低本底测量和脉冲形状判别法,较好地确定了LaBr_3的本征本底,本征本底主要来自La_(138)和Ac_(227)。提出了一种利用三个内污染峰进行自校正的方法,以消除长期监测过程中的峰漂移。通过不同温度下的实验,证明该方法有利于保持长期稳定性。为了监测海洋放射性,通过水槽实验和蒙特卡罗模拟计算了谱仪的效率。

英文摘要:

An underwater in situ gamma ray spectrometer based on LaBr3 was developed and optimized to monitor marine radioactivity. The intrinsic background mainly from La138 and Ac227 of LaBr3 was well determined by low background measurement and pulse shape discrimination method. A method of self-calibration using three internal contaminant peaks was proposed to eliminate the peak shift during long term monitoring. With experiments under different temperatures, the method was proved to be helpful for maintaining long term stability. To monitor the marine radioactivity, the spectrometer efficiency was calculated via water tank experiment as well as Monte Carlo simulation.