从单个封装探测器到INTEGRAL卫星的谱仪:预测高γ能量下的峰总比
From a single encapsulated detector to the spectrometer for INTEGRAL satellite: predicting the peak-to-total ratio at high gamma-energies
摘要:
在最近的两篇论文(R。Kshetri,JINST 2012 7 P04008;同上,P07006),概率形式主义被引入到预测封装型复合锗探测器的响应,如SPI(光谱仪的INTEGRAL卫星)。预测的峰-总和峰-背景比给出在1.3兆电子伏的addback操作模式。在两篇独立的论文中讨论了该形式在三叶草锗探测器中的应用。Kshetri,JINST 2012 7 P07008;同上,P08015)。使用这些文件中开发的基本方法,我们第一次提出了一个程序,用于计算的峰值总比的簇探测器的伽马能量高达8兆电子伏。结果显示为裸和抑制探测器以及单晶和addback操作模式。我们已经考虑了实验数据(i)峰总比在1.3 MeV,和(ii)单探测器效率和addback因子为其他能量高达8 MeV。使用这些数据,计算其他复合探测器的峰总比的近似方法,示出。考虑到SPI光谱仪的数据,我们的方法(能量高达8兆电子伏)的实验验证已得到证实。我们已经讨论了各种操作模式和抑制情况之间的比较。本文是复合锗探测器系列论文的第五篇,首次讨论了由小球、团簇和SPI探测器组成的复杂探测器的折叠分布和峰总比的变化。我们的工作可以提供指导,在设计新的复合探测器,并在与现有的高能γ射线探测器进行实验研究。
英文摘要:
In two recent papers (R. Kshetri, JINST 2012 7 P04008; ibid., P07006), a probabilistic formalism was introduced to predict the response of encapsulated type composite germanium detectors like the SPI (spectrometer for INTEGRAL satellite). Predictions for the peak-to-total and peak-to-background ratios are given at 1.3 MeV for the addback mode of operation. The application of the formalism to clover germanium detector is discussed in two separate papers (R. Kshetri, JINST 2012 7 P07008; ibid., P08015). Using the basic approach developed in those papers, for the first time we present a procedure for calculating the peak-to-total ratio of the cluster detector for gamma-energies up to 8 MeV. Results are shown for both bare and suppressed detectors as well as for the single crystal and addback modes of operation. We have considered the experimental data of (i) peak-to-total ratio at 1.3 MeV, and (ii) single detector efficiency and addback factor for other energies up to 8 MeV. Using this data, an approximate method of calculating the peak-to-total ratio of other composite detectors, is shown. Experimental validation of our approach (for energies up to 8 MeV) has been confirmed considering the data of the SPI spectrometer. We have discussed about comparisons between various modes of operation and suppression cases. The present paper is the fifth in the series of papers on composite germanium detectors and for the first time discusses about the change in fold distribution and peak-to-total ratio for sophisticated detectors consisting of several modules of miniball, cluster and SPI detectors. Our work could provide a guidance in designing new composite detectors and in performing experimental studies with the existing detectors for high energy gamma-rays.
机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。