A probability model has been presented for understanding the operation of an array of encapsulated germanium detectors generally known as composite detector. The addback mode of operation of a composite detector has been described considering the absorption and scattering of gamma-rays. Considering up to triple detector hit events, we have obtained expressions for peak-to-total and peak-to-background ratios of the cluster detector, which consists of seven hexagonal closely packed encapsulated HPGe detectors. Results have been obtained for the miniball detectors comprising of three and four seven hexagonal closely packed encapsulated HPGe detectors. The formalism has been extended to the SPI spectrometer which is a telescope of the INTEGRAL satellite and consists of nineteen hexagonal closely packed encapsulated HPGe detectors. This spectrometer comprises of twelve detector modules surrounding the cluster detector. For comparison, we have considered a spectrometer comprising of nine detector modules surrounding the three detector configuration of miniball detector. In the present formalism, the operation of these sophisticated detectors could be described in terms of six probability amplitudes only. Using experimental data on relative efficiency and fold distribution of cluster detector as input, the fold distribution and the peak-to-total, peak-to-background ratios have been calculated for the SPI spectrometer and other composite detectors at 1332 keV. Remarkable agreement between experimental data and results from the present formalism has been observed for the SPI spectrometer.
Measurement of the Background Activities of a 100Mo-enriched Powder Sample for an AMoRE Crystal Material by using Fourteen High-Purity Germanium Detectors
Intrinsic Spatial Position Resolution of P-type Point-Contact Germanium Detector
College of Physics, Sichuan University(四川大学物理学院);Key Laboratory of Particle and Radiation Imaging (Ministry of Education) and Department of Engineering Physics, Tsinghua University(清华大学工程物理系粒子与辐射成像教育部重点实验室)
中国暗物质实验(CDEX)的目标是在中国锦屏地下实验室(CJPL)直接搜索轻弱相互作用大质量粒子(WIMP),覆盖层约为2400米。报道了CDEX-1 994 g p型点接触锗(pPCGe)探测器的实验结果。研究计划的追求,以进一步降低物理阈值,通过改进硬件和数据分析。目前正在测试CDEX-10实验,其pPCGe阵列的目标质量范围为10公斤。本研究亦将介绍CDEX计划发展为“CDEX-1 T实验”的过程,其中包括使用吨级锗探测器阵列。
Search for Pauli Exclusion Principle Violating Atomic Transitions and Electron Decay with a P-type Point Contact Germanium Detector
使用在Kimballton地下研究设施运行的p型点接触高纯锗探测器收集的89.5 kg-d数据,对违反Pauli不相容原理的K-α电子跃迁进行了搜索。在90% C. L时,跃迁寿命的下限为5.8x10^30秒。通过寻找在10.6 keV处的峰值来设定,该峰值由在跃迁之后存在的X射线和俄歇电子产生。为了寻找原子K壳层电子衰变为中微子的过程,也做了类似的分析,结果是在90 C. L时,衰变的下限为6.8x10^30秒。据估计,MAJORANA DEMONSTRATOR,一个44公斤的p型点接触探测器阵列,将寻找76-Ge的无中微子双β衰变,可以改善这些排除限制的数量级后,三年的操作。
Results of direct dark matter detection with CDEX experiment at CJPL
中国暗物质实验(CDEX)位于中国锦屏地下实验室(CJPL),其覆盖层约为2400米,旨在直接搜索轻弱相互作用大质量粒子(WIMP)。单元件994克p型点接触(PPC)锗探测器(CDEX-1B)在固体被动屏蔽系统内运行。为了实现更低的背景,将原型10 kg PPC锗探测器阵列(CDEX-10)直接浸入液氮中,该原型10 kg PPC锗探测器阵列(CDEX-10)由三个探测器串组成,每个探测器串具有三个锗晶体。在160 eV的能量阈值下,分别用能谱和年度调制分析确定了WIMP与核散射的极限。在排除Migdal效应的基础上,对CDEX-1B的数据进行了重新分析,以寻找亚GeV的WIMP。最后,对CJPL-Ⅱ的CDEX实验的未来计划进行了介绍。
Design and Performance of the GERDA Low-Background Cryostat for Operation in Water
在寻找$^{76}$ Ge的无中微子双β衰变过程中,在INFN国立大萨索实验室进行的锗探测器阵列(GERDA)实验在感兴趣的区域获得了远低于10 $^{-3}$ cts/(keV $\cdot$ kg $\cdot$ yr)的前所未有的低本底。它利用了第一次实现的一种新的屏蔽概念的基础上,一个大型低温恒温器充满了液体惰性气体,浸没在水箱。锗探测器无需在液氩中封装即可工作。氩气和水将实验室和低温恒温器构造材料的环境背景屏蔽到可忽略的水平。在此期间,各种实验都采用了同样的方法。本文概述了64 m $^3$液氩低温恒温器及其相关基础设施的设计和运行经验。讨论包括与水箱中大型低温恒温器的操作相关的具有挑战性的安全问题。
Probing Internal Conversion and Dark-Matter-Induced De-excitation of 180mTa with a gamma-ray TES Array
Research Center for Neutrino Science, Tohoku University(东北大学中微子科学研究中心);Department of Human Science, Obihiro University of Agriculture and Veterinary Medicine(带广畜产大学人类科学系);National Institute of Advanced Industrial Science and Technology (AIST)(产业技术综合研究所);Research Center for Nuclear Physics, The University of Osaka(大阪大学核物理研究中心);Department of Physics, The University of Osaka(大阪大学物理系)