arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2210.16161physics.ins-detphysics.app-ph
收藏

保罗·谢尔研究所用于μ子诱发X射线发射(MIXE)的无损检测锗阵列(GIANT)装置

GermanIum Array for Non-destructive Testing (GIANT) setup for Muon Induced X-ray Emission (MIXE) at the Paul Scherrer Institute

Lars Gerchow, Sayani Biswas, Gianluca Janka, Carlos Vigo, Andreas Knecht, Stergiani Marina Vogiatzi, Narongrit Ritjoho, Thomas Prokscha, Hubertus Luetkens, Alex Amato

AI总结:

本文介绍PSI在SμS建造并调试的GIANT专用MIXE谱仪,表征其束斑、分辨率与探测效率,并展示其在多领域无损元素分析中的应用。

摘要:

利用μ子X射线研究核半径等元素性质的历史可追溯至20世纪70年代。这促成了20世纪80年代保罗·谢尔研究所(PSI)在μ子诱发X射线发射(Muon Induced X-ray Emission,MIXE)技术方面的开创性工作,该技术用于元素组成的无损评估。近年来,该方法在全球大多数μ子设施中迎来复兴、改进和应用。在此方面,PSI凭借其瑞士μ子源(SμS)的高计数率连续μ子束提供了独特能力。我们在此报告PSI专用MIXE谱仪——无损检测锗阵列(GermanIum Array for Non-destructive Testing,GIANT)装置的决策、建造和调试。多次实验活动凸显了PSI的MIXE的出色能力,例如仅需1小时数据采集即可分辨低至1 at%的元素浓度,测量从铁到铅等元素的同位素比,以及表征由μ子核俘获诱发的γ射线。使用专用带电粒子径迹探测器表征得到,在25和45 MeV/c时,靶上束斑分别为22.06±0.18和14.45±0.06 mm。对高纯锗(High Purity Germanium,HPGe)信号的先进分析还可将1 MeV处的能量分辨率和时间分辨率分别提升至约1 keV和20 ns。在GIANT装置中,平均探测器在E=1000 keV时的光电峰效率为ε̅_E=0.11%,能量分辨率为σ̅_E=0.8 keV。GIANT装置在SμS的整体性能使其得以启动内容丰富的用户项目,包括考古样品、锂离子电池研究以及与产业界的合作。未来改进将包括基于模拟的分析和更高程度的自动化,例如自动扫描一系列μ子动量以及自动更换样品。

英文摘要:

The usage of muonic X-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties, on the Muon Induced X-ray Emission (MIXE) technique for a non-destructive assessment of elemental compositions. In the recent years, this method has seen a rebirth, improvement and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (S$μ$S). We report here the decision making, construction and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g. resolving down to 1 at% elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beamspots were characterized with a dedicated charged particle tracker to be 22.06$\pm$0.18 and 14.45$\pm$0.06 mm for 25 and 45 MeV/c, respectively. Advanced analysis of the High Purity Germanium (HPGe) signals further allows to improve energy and timing resolutions to ~1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of $\overline{ε_E}$ =0.11% and an energy resolution of $\overline{σ_E}$ = 0.8 keV at E=1000 keV. The overall performance of the GIANT setup at S$μ$S allowed to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with industry. Future improvements will include a simulation based analysis and a higher degree of automation, e.g. automatic scans of a series of muon momenta and automatic sample changing.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑