arXivDaily arXiv每日学术速递 周一至周五更新
感恩节,周五至周末无更新,大家顺遂。周一再来吧
arXiv 2502.13091cond-mat.soft
收藏

广义偏振与时间分辨荧光为脂质囊泡中不同 Laurdan 群体提供证据

Generalized Polarization and time-resolved fluorescence provide evidence for different populations of Laurdan in lipid vesicles

M. Bacalum, M. Radu, S. Osella, S. Knippenberg, M. Ameloot

AI总结:

本研究通过 DMPC、DPPC 大单层囊泡的 GP 与时间分辨荧光角度测量,发现不同脂质相和发射通道中的异常寿命及强度变化,为膜内 Laurdan 存在不同群体及弯曲构象提供实验证据。

摘要:

溶致变色染料 Laurdan 被广泛用于感知模型膜和生物膜的脂质堆积。其荧光发射最大值从凝聚膜(So)中约 440 nm(蓝色通道)移动到液晶相(Lα)中约 490 nm(绿色通道)。尽管基于荧光强度的广义偏振(GP)被广泛用于表征脂质膜,但蓝色和绿色通道中的 Laurdan 荧光寿命较少用于该目的。在此,我们通过对 DMPC 和 DPPC 的大单层囊泡的 So 相和 Lα 相进行光谱测量,探索 GP 与荧光寿命之间的相关性。对于两种脂质相,在每个光学通道中都观察到 GP 与寿命之间呈正相关。荧光强度、GP 和荧光寿命取决于激发光线性偏振方向与光学截面膜局部法线之间的夹角。这种角度变化取决于脂质相和发射通道。So 相中蓝色和绿色通道以及 Lα 相中蓝色通道的 GP 和荧光强度在接近 90° 处呈现最小值。令人惊讶的是,Lα 相中绿色通道的强度在接近 90° 处达到最大值。两个光学通道中的荧光寿命在 So 相和 Lα 相中也都在接近 90° 处达到明显最小值,例外是 Lα 相蓝色通道中的寿命较短且角度变化极小。据我们所知,这些实验观察首次证明了脂质膜中存在 Laurdan 的弯曲构象,正如此前分子动力学计算所提出的那样。

英文摘要:

The solvatochromic dye Laurdan is widely used in sensing the lipid packing of both model and biological membranes. The fluorescence emission maximum shifts from about 440 nm (blue channel) in condensed membranes (So) to about 490 nm (green channel) in the liquid-crystalline phase (Lα). Although the fluorescence intensity based generalized polarization (GP) is widely used to characterize lipid membranes, the fluorescence lifetime of Laurdan, in the blue and the green channel, is less used for that purpose. Here we explore the correlation between GP and fluorescence lifetimes by spectroscopic measurements on the So and Lα phases of large unilamellar vesicles of DMPC and DPPC. A positive correlation between GP and the lifetimes is observed in each of the optical channels for the two lipid phases. Fluorescence intensities, GP and fluorescence lifetimes depend on the angle between the orientation of the linear polarization of the excitation light and the local normal to the membrane of the optical cross-section. This angular variation depends on the lipid phase and the emission channel. GP and fluorescence intensities in the blue and green channel in So and in the blue channel in Lα exhibit a minimum near 90o. Surprisingly, the intensity in the green channel in Lα reaches a maximum near 90o. The fluorescence lifetimes in the two optical channels also reach a pronounced minimum near 90o in So and Lα, apart from the lifetime in the blue channel in Lα where the lifetime is short with minimal angular variation. To our knowledge, these experimental observations are the first to demonstrate the existence of a bent conformation of Laurdan in lipid membranes, as previously suggested by molecular dynamics calculations.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑