AI总结:

本文报道了单片CMOS探测器内部增益的初步测试结果,展示了其在高能物理实验中的应用潜力。

摘要:

本文报告了对首个单片LGAD原型的测试结果,该原型集成在定制的110 nm CMOS工艺中,具有48 μm的耗尽活性体积厚度。该原型由像素阵列组成,每个像素的总尺寸为100 μm×250 μm,并包含高速前端放大器。在描述传感器和电子架构后,报告了实验室和在束测量结果。使用红外脉冲激光装置进行的光学测试显示传感器内部增益约为2.5。使用相同实验装置,电子抖动被发现在50 ps到150 ps之间,具体取决于信号幅度。此外,使用在欧洲核子研究中心(CERN)的质子同步加速器(PS)T10设施进行的测试束分析,表明整体探测器时间分辨率为234 ps至244 ps。进一步的TCAD研究,基于从C(V)测量中提取的掺杂分布,确认了测试器件上测得的倍增增益。最后,TCAD模拟被用于调整未来增益层植入的掺杂浓度,目标是具有更高雪崩增益的传感器。这种调整预计将提高未来生产传感器的时序性能,以应对未来大多数高能和高亮度物理实验中预期的高事件率,其中时间分辨率对于区分重叠事件和粒子识别(PID)至关重要。

英文摘要:

In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 $μ$m. This prototype is formed by a pixel array where each pixel has a total size of 100 $μ$m $\times$ 250 $μ$m and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from $C(V)$ measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).