Magnetic Resonance Imaging (MRI) has become a popular modality in guiding minimally invasive thermal therapies, due to its advanced, non-ionizing, imaging capabilities and its ability to record changes in temperature. A variety of MR thermometry techniques have been developed over the years, and Proton Resonance Frequency (PRF) Shift Thermometry is the current clinical gold standard to treat a variety of cancers. It is used extensively to guide hyperthermic thermal ablation techniques such as high-intensity focused ultrasound (HIFU) and laser-induced thermal therapy (LITT). Essential attributes of PRF Shift Thermometry include excellent linearity with temperature, good sensitivity, and independence from tissue type. This non-invasive temperature mapping method gives accurate quantitative measures of the temperature evolution inside biological tissues. In this review, the current status and new developments in the fields of MR-guided HIFU and LITT are presented with an emphasis on breast, prostate, bone, uterine and brain treatments.
Referenceless Proton Resonance Frequency Thermometry Using Deep Learning with Self-Attention
Shanghai Jiao Tong University(上海交通大学);Soochow University(东吴大学);Harvard Medical School(哈佛医学院);Brigham and Women’s Hospital(布莱根妇女医院);Shanghai Sixth People’s Hospital Affiliated to Shanghai Jiao Tong University School of Medicine(上海交通大学医学院附属第六人民医院)
Highly sensitive and high throughput magnetic resonance thermometry using superparamagnetic nanoparticles
磁共振成像(MRI)能够在癌性肿瘤的热消融过程中进行无创3D测温。虽然T1或T2对比MRI对温度相对不敏感,但具有更高温度敏感性的技术(如化学位移或扩散成像)会受到运动伪影和长扫描时间的影响。我们描述了一种高灵敏度和高通量MR测温方法,它不容易受到运动伪影的影响。我们使用超顺磁性氧化铁纳米粒子(SPION)破坏水质子的T2。运动变窄导致T2和扩散常数之间成比例,仅取决于特定环境中的温度。结果表明,对于纯水,核磁共振(NMR)谱线宽度和T2遵循与水的自扩散常数相同的温度依赖性。因此,T2映射是存在SPION的扩散映射,T2是温度计。对于纯水,在9.4 T MRI扫描仪中64 x 64图像(体素尺寸= 0.5 mm x 0.5 mm x 3 mm)的T2标测导致温度分辨率为0.5 K,扫描时间为2分钟。这表明一种高灵敏度和高通量的MR测温技术,可能用于在热治疗期间监测生物组织或用于诊断。
A full-scale clinical prototype for proton range verification using prompt gamma-ray spectroscopy
我们提出了一个全尺寸的临床原型系统,在体内范围验证的质子束,使用即时伽玛射线光谱法。探测系统由八个LaBr3吸收器和一个钨准直器组成,安装在一个旋转框架上。定制的电子和校准算法已被开发用于测量的能量和时间分辨的伽玛射线光谱在质子照射在临床剂量率。使用实验确定的核反应截面和GPU加速的蒙特卡罗模拟,为每个单独的伽马射线束创建预期的伽马射线发射的详细模型。通过最小化测量和该模型之间的差异来确定质子束的绝对范围,留下束的绝对范围和被照射物质的元素浓度作为自由参数。该系统的特点是在一个类似临床的情况下,通过照射不同的phantomes与扫描的准直光束。将0.9 Gy的剂量输送至5 x 10 x 10 cm $^3$靶,射束电流2 nA入射到体模上。使用不同的范围移位器和材料来测试验证方法的稳健性并计算检测范围的准确度。当在10 mm半径和10 mm深度的圆柱形区域内聚集质子束点时,确定远端能量层每个点的绝对质子范围,平均统计精度为1.1 mm,置信水平为95%,平均系统偏差为0.5 mm。我们引入的小范围误差被成功地检测到,即使元素组成的大差异也不会影响范围验证的准确性。这些结果表明,我们的系统适用于我们即将进行的临床研究中患者治疗期间的范围验证。
The First Nozzle-Mounted Compton Camera Prompt Gamma Imaging System for In Vivo Proton Therapy Dose Verification
University of Maryland School of Medicine(马里兰大学医学院);University of Cape Town(开普敦大学);University of Wisconsin School of Medicine and Public Health(威斯康星大学医学院与公共卫生学院);University of Maryland, Baltimore County(马里兰大学巴尔的摩县分校);H3D, Inc.(H3D公司)
Variation of the relative biological effectiveness with fractionation in proton therapy: analysis of prostate cancer response
Instituto de Investigación Sanitaria de Santiago (IDIS)(圣地亚哥卫生研究所);Complexo Hospitalario Universitario de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学医院复合体);Istituto Nazionale di Fisica Nucleare-Torino Section(意大利国家核物理研究所都灵分部);Universidade de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学)
Commissioning of a clinical pencil beam scanning proton therapy unit for ultrahigh dose rates (FLASH)
目的:这项工作的目的是提供一个灵活的平台,通过调整以前的临床笔形束扫描机架的照射剂量率与质子的FLASH研究。方法:PSI机架1治疗患者直至2018年12月。我们优化了光束线参数,以将从PSI COMET加速器提取的250 MeV光束传输到治疗室,最大限度地提高光束强度到样品的传输。我们的特点是剂量监测器的机架上,以确保良好的控制剂量,提供点扫描模式。我们的特点是不同的剂量率和字段大小的传输辐照的光束。我们探索了扫描的可能性,以使大目标的共形辐射或透射辐射(横向扫描)。结果:我们实现了从回旋加速器到治疗室的86%的传输。我们达到了9000 Gy/s的峰值剂量率在3毫米水当量深度,沿一个单一的笔形束的中心轴。单点闪光照射可实现高达5 × 5 mm $^{2}$的射野尺寸。快速横向扫描可覆盖16 x 1.2 cm $^{2}$的视野。通过使用安装在桅杆上的量程转换器,我们能够在19.6至37.9厘米的水中跨越深度。输送的各种剂量水平的精度小于1%。结论:我们已经实现了一个质子FLASH照射设置能够连续调查宽剂量率谱,从1到9000 Gy/s的单点照射,以及在笔形束扫描模式。因此,我们已经开发了一个多功能的测试平台,闪存的研究。
Enabling Clinical Use of Linear Energy Transfer in Proton Therapy for Head and Neck Cancer -- A Review of Implications for Treatment Planning and Adverse Events Study
Mayo Clinic(梅奥诊所);China Three Gorges University(三峡大学);Guangzhou Concord Cancer Center(广州协和肿瘤中心);the University of Georgia(佐治亚大学);the University of Texas MD Anderson Cancer Center(德克萨斯大学安德森癌症中心);New York Proton Center(纽约质子中心);Memorial Sloan Kettering Cancer Center(纪念斯隆-凯特琳癌症中心)
A new detector for the beam energy measurement in proton therapy: a feasibility study
在粒子治疗中最迫切的改进之一是用于射束质量评估和用于在照射期间监测射束能量调制的快速程序。事实上,粒子束能量的在线测量可以允许评估治疗期间的穿透范围,鼓励开发用于移动目标的新剂量输送技术。为此,提出了一种新设备的概念证明,该设备能够在几秒钟内从质子的飞行时间(ToF)测量临床质子束的能量(从60到230 MeV)。该原型由两个超快速硅探测器(UFSD)垫,具有80微米的有效厚度和3 × 3 mm 2的敏感区域,沿望远镜配置中的光束方向对齐,连接到宽带放大器并通过数字化仪读出。在Centro Nazionale di Adroterapia Oncologica(CNAO,Pavia,Italy)进行测量,使用五种不同的临床射束能量,每种能量的传感器之间有四种距离(7 - 97 cm)。为了从测量的平均ToF中获得束流能量,考虑了几种系统效应,开发了蒙特卡罗模拟来验证该方法,并采用全局拟合方法来校准系统。计算结果与审计署提供的当量水深能量值进行了对比。几百keV的偏差已经实现了所有考虑的质子束能量为67和97厘米的传感器之间的距离和几秒钟的照射是必要的收集所需的统计数据。这些初步结果表明,UFSD望远镜可以在几秒钟内达到临床应用所需的精度,因此鼓励进一步研究对本原型的改进和优化。
A novel methodology to estimate pileup effects and induced error in microdosimetric spectra
GSI Helmholtzzentrum für Schwerionenforschung(GSI亥姆霍兹重离子研究中心);Trento Institute for Fundamental Physics and Application (TIFPA)(特伦托基础物理与应用研究所);University of Miami Miller School of Medicine(迈阿密大学米勒医学院)
Combined photon-proton modeling of radiation-induced brain imaging changes supports variability in proton relative biological effectiveness and increased periventricular radiosensitivity
TUD Dresden University of Technology(德累斯顿工业大学);Helmholtz-Zentrum Dresden-Rossendorf(德累斯顿-罗斯多夫亥姆霍兹中心);TU Dortmund University(多特蒙德工业大学);National Center for Tumor Diseases (NCT)(国家肿瘤疾病中心);Institute of Neuroradiology(神经放射学研究所);German Cancer Research Center (DKFZ)(德国癌症研究中心)
Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
Instituto de Física Corpuscular (CSIC-University of Valencia)(粒子物理研究所(西班牙科学理事会-瓦伦西亚大学));Universitat Politècnica de Catalunya(加泰罗尼亚理工大学);GSI Helmholtzzentrum für Schwerionenforschung(德国重离子研究中心);Institut für Kernphysik, Technische Universität Darmstadt(达姆施塔特工业大学核物理研究所);West German Proton Therapy Centre(西德质子治疗中心)