Variation of the relative biological effectiveness with fractionation in proton therapy: analysis of prostate cancer response

Instituto de Investigación Sanitaria de Santiago (IDIS)(圣地亚哥卫生研究所);Complexo Hospitalario Universitario de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学医院复合体);Istituto Nazionale di Fisica Nucleare-Torino Section(意大利国家核物理研究所都灵分部);Universidade de Santiago de Compostela(圣地亚哥-德孔波斯特拉大学)

Juan Pardo-Montero, Miguel Pombar, Antonio Gómez-Caamaño, Simona Giordanengo, Isabel González-Crespo

AI总结:

本文基于临床数据,利用LQ模型和泊松TCP公式分析质子治疗中分次剂量对RBE的影响,发现RBE随分次剂量单调递减,且与光子和质子照射的α、β值变化有关。

摘要:

目的:提出一种方法,利用肿瘤控制概率(TCP)的临床数据来分析分次剂量对RBE的变异性,并将其应用于研究质子治疗对前列腺癌的反应。方法与结果:通过LQ模型和泊松TCP公式分析RBE与分次剂量的依赖关系。临床TCP数据表明,随着分次剂量增加,RBE值呈下降趋势,尽管接近名义值1.1。结论:提出分析不同分次方案下RBE的方法,并利用临床数据研究前列腺癌反应,结果显示RBE随分次剂量增加而单调递减,符合LQ模型和光子与质子照射间α、β值变化的预期。然而,研究结果需谨慎对待,可能受模型限制或临床数据集的影响。

英文摘要:

Purpose: To present a methodology to analyze the variation of RBE with fractionation from clinical data of tumor control probability (TCP) and to apply it to study the response of prostate cancer to proton therapy. M&M: We analyzed the dependence of the RBE on the dose per fraction by using the LQ model and the Poisson TCP formalism. Clinical TCPs for prostate cancer treated with photon and proton therapy for conventional fractionation (2 Gy(RBE)x37 fractions), moderate hypofractionation (3 Gy(RBE)x20 fractions) and hypofractionation (7.25 Gy(RBE)x5 fractions) were obtained from the literature and analyzed. Results: The theoretical analysis showed three distinct regions with RBE monotonically decreasing, increasing or staying constant with the dose per fraction, depending on the change of (α, \{beta}) values between photon and proton irradiation (the equilibrium point being at(α_p/\{beta}_p)=(α_X/\{beta}_X)(α_X/α_p)). An analysis of the clinical data showed RBE values that decline with increasing dose per fraction: for low risk RBE=1.124, 1.119, and 1.102 for 1.82 Gy, 2.73 Gy and 6.59 Gy per fraction (physical proton doses), respectively; for intermediate risk RBE=1.119, and 1.102 for 1.82 Gy, and 6.59 Gy per fraction (physical proton doses), respectively. These values are nonetheless very close to the nominal 1.1 value. Conclusions: We presented a methodology to analyze the RBE for different fractionations, and we used it to study clinical data for prostate cancer. The analysis shows a monotonically decreasing RBE with increasing dose per fraction, which is expected from the LQ formalism and the changes in (α, \{beta}) between photon and proton irradiation. However, the calculations in this study have to be considered with care as they may be biased by limitations in the modeling and/or by the clinical data set used for the analysis.