放射治疗计划中Pareto最优剂量分布的生成

Generating Pareto optimal dose distributions for radiation therapy treatment planning

Dan Nguyen, Azar Sadeghnejad Barkousaraie, Chenyang Shen, Xun Jia, Steve Jiang

摘要:

放射疗法治疗计划目前需要在计划器和治疗计划系统之间以及在计划器和医生之间进行多次试错迭代以进行讨论/咨询。医生对特定患者的偏好无法轻易量化并准确传达给计划者。在这项研究中,我们提出了一种实时体积帕累托表面剂量生成深度学习神经网络,可以在医生分割后使用,添加有形和可量化的终点来描绘规划器。从70名前列腺患者中,我们首先生成了84,000个调强放射治疗计划(每个患者1,200个计划),对Pareto曲面进行采样,代表了计划靶体积(PTV)和危险器官(OAR)之间的各种权衡,包括膀胱,直肠,左股骨,右股骨和身体。我们将数据分为10名测试患者和60名训练/验证患者。然后,我们训练了一个分层密集连接的卷积U网(HD U网),以获取PTV和代表OAR掩码和权重的回避图,并预测优化计划。HD U-net能够准确预测3D Pareto最佳剂量分布,平均[平均值,最大值]剂量误差为[3.4%,7.7%](PTV),[1.6%,5.6%](膀胱),[3.7%,4.2%](直肠),[3.2%,8.0%](左股骨)、[2.9%,7.7%](右股骨)和[0.04%,5.4%](身体)处方剂量。PTV剂量覆盖预测也非常相似,误差为1.3%(D98)和2.0%(D99)。均匀性也相似,平均相差0.06。神经网络可以在1.7秒内预测剂量。临床上,优化和剂量计算要慢得多,需要5-10分钟。

英文摘要:

Radiotherapy treatment planning currently requires many trail-and-error iterations between the planner and treatment planning system, as well as between the planner and physician for discussion/consultation. The physician's preferences for a particular patient cannot be easily quantified and precisely conveyed to the planner. In this study we present a real-time volumetric Pareto surface dose generation deep learning neural network that can be used after segmentation by the physician, adding a tangible and quantifiable end-point to portray to the planner. From 70 prostate patients, we first generated 84,000 intensity modulated radiation therapy plans (1,200 plans per patient) sampling the Pareto surface, representing various tradeoffs between the planning target volume (PTV) and the organs-at-risk (OAR), including bladder, rectum, left femur, right femur, and body. We divided the data to 10 test patients and 60 training/validation patients. We then trained a hierarchically densely connected convolutional U-net (HD U-net), to take the PTV and avoidance map representing OARs masks and weights, and predict the optimized plan. The HD U-net is capable of accurately predicting the 3D Pareto optimal dose distributions, with average [mean, max] dose errors of [3.4%, 7.7%](PTV), [1.6%, 5.6%](bladder), [3.7%, 4.2%](rectum), [3.2%, 8.0%](left femur), [2.9%, 7.7%](right femur), and [0.04%, 5.4%](body) of the prescription dose. The PTV dose coverage prediction was also very similar, with errors of 1.3% (D98) and 2.0% (D99). Homogeneity was also similar, differing by 0.06 on average. The neural network can predict the dose within 1.7 seconds. Clinically, the optimization and dose calculation is much slower, taking 5-10 minutes.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑