Dosimetric uncertainties related to the elasticity of bladder and rectal walls: Adenocarcinoma of the prostate

Cyril Voyant, Katia Biffi, Leschi Delphine, Jerome Briancon, Celine Lantieri Marcovici

摘要:

目的. - 放射治疗是前列腺癌的一种重要治疗方法。在治疗过程中,膀胱和直肠充盈难以量化,无法通过单次和初始CT扫描采集进行测量。一些方法,如图像引导的放射治疗和剂量引导的放射治疗,旨在通过定期CT采集来补偿这种缺失的信息。其目的是调整患者的位置、射束配置或处方剂量以达到剂量测定依从性。方法. - 在计算新CT扫描采集的原始弹道后,我们评估了54名患者的器官运动(和充盈)。对前列腺、膀胱和直肠进行了新的勾画,以确定新的位移和定义器官剂量误差(等效均匀剂量、平均剂量和剂量体积直方图)。结果- 新的CT采集证实膀胱和直肠体积在会话期间不是恒定的。一些病例显示,先前验证的治疗计划变得不适用。提出的解决方案是当膀胱体积改变显著时校正剂量测定。结果表明,膀胱剂量的稳定性得到改善,D50误差降低了25.3%,平均剂量误差降低了5.1%,等效均匀剂量误差降低了2.6%。对于直肠,该方法仅将误差降低1%。这个过程可以降低初始扫描和后续治疗之间不匹配的风险。结论- 对于提出的方法,锥束CT是必要的,以正确定位等中心,量化膀胱和直肠的体积变化和沉积剂量。如果超过膀胱(或直肠)体积修改限值,则进行剂量测定。为了确定这些限值,我们计算出等效均匀剂量的容差为10%(与第一次剂量测定的初始值相比),这代表膀胱11%的废弃剂量测定,直肠4%。

英文摘要:

Purpose. - Radiotherapy is an important treatment for prostate cancer.During treatment sessions, bladder and rectal repletion is difficult to quantify and cannot be measured with a single and initial CT scan acquisition. Some methods, such as image-guided radiation therapy and dose-guided radiation therapy, aimto compensate thismissing information through periodic CT acquisitions. The aimis to adapt patient's position, beam configuration or prescribed dose for a dosimetric compliance. Methods. -We evaluated organmotion (and repletion) for 54 patients after having computed the original ballistic on a new CT scan acquisition. A new delineation was done on the prostate, bladder and rectum to determine the newdisplacements and define organ dosesmistakes (equivalent uniformdose, average dose and dose-volume histograms). Results. - The new CT acquisitions confirmed that bladder and rectal volumes were not constant during sessions. Some cases showed that previously validated treatment plan became unsuitable. A proposed solution is to correct dosimetries when bladder volume modifications are significant. The result is an improvement for the stability of bladder doses, D50 error is reduced by 25.3%, mean dose error by 5.1% and equivalent uniform dose error by 2.6%. For the rectum this method decreases errors by only 1%. This process can reduce the risk of mismatch between the initial scan and following treatment sessions. Conclusion. - For the proposedmethod, the cone-beamCT is necessary to properly position the isocenter and to quantify bladder and rectal volume variation and deposited doses. The dosimetries are performed in the event that bladder (or rectum) volume modification limits are exceeded. To identify these limits, we have calculated that a tolerance of 10% for the equivalent uniformdose (compared to the initial value of the first dosimetry), this represents 11% of obsolete dosimetries for the bladder, and 4% for the rectum.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑