arXivDaily arXiv每日学术速递 周一至周五更新
arXiv 2310.02047physics.ins-det
收藏

4H-SiC PiN二极管中的中子辐射诱导效应

Neutron Radiation induced Effects in 4H-SiC PiN Diodes

Andreas Gsponer, Philipp Gaggl, Jürgen Maier, Richard Thalmeier, Simon Emanuel Waid, Thomas Bergauer

AI总结:

本研究针对宽禁带半导体SiC在强辐射环境的应用需求,测试了不同中子注量下4H-SiC PiN二极管的电学与电荷收集特性,明确了辐照损伤规律及正反向偏压下的探测性能差异。

摘要:

碳化硅(SiC)是一种宽禁带半导体,是空间、核聚变或未来高亮度对撞机等恶劣环境中应用的理想候选材料。由于禁带宽度大,SiC器件的漏电流极小,即使在接受极高注量的辐照后也是如此,这使其能够在无冷却且高温的条件下工作。本研究采用电流-电压、电容-电压以及电荷收集效率(CCE)测量方法,研究了中子辐照对50μm p-n型4H-SiC二极管的影响,实验的中子注量最高达$1\times 10^{16}$ n$_{\text{eq}}$/cm$^2$。所研究器件的漏电流始终极小,在1.1 kV反向偏压下低于10 pA。在正向偏压下,观察到电流显著下降,这归因于深能级缺陷对外延层掺杂的补偿作用导致外延电阻率升高。研究分别利用放射源产生的α粒子、MedAustron离子治疗中心的62.4 MeV质子束以及UV-TCT(紫外瞬态电流技术)对CCE进行了评估。结果表明,反向偏压下的电荷收集效率与1 MeV等效注量$Φ_{\text{eq}}$直接成比例关系,即$\text{CCE} \times Φ_{\text{eq}}^{-0.63\boldsymbol{\times}0.01}$。在注量高达$1 \times 10^{15}$ n$_{\text{eq}}$/cm$^2$时,仍能获得优于50%的CCE。由于正向电流较低,器件在正向偏压下也可实现粒子探测,且正向偏压下的CCE相较于反向偏压有所提升。此外,研究还观察到CCE与注入电荷量存在显著依赖关系:在α粒子和UV-TCT测量中,CCE超过了100%,这一现象需要进一步的系统研究。

英文摘要:

Silicon carbide (SiC) is a wide band gap semiconductor and an attractive candidate for applications in harsh environments such as space, fusion, or future high luminosity colliders. Due to the large band gap, the leakage currents in SiC devices are extremely small, even after irradiation to very high fluences, enabling operation without cooling and at high temperatures. This study investigates the effect of neutron irradiation on 50$μ$m p-n 4H-SiC diodes using current-voltage, capacitance-voltage, and charge collection efficiency (CCE) measurements up to neutron fluences of $1\times 10^{16}$ n$_{\text{eq}}$/cm$^2$. The leakage currents of the investigated devices remained extremely small, below 10 pA at 1.1 kV reverse bias. In the forward bias, a remarkable drop of the current was observed, which was attributed to an increased epi resistivity due to compensation of the epi layer doping by deep-level defects. The CCE was evaluated for alpha particles from a radioactive source, a 62.4 MeV proton beam at the MedAustron ion therapy center and using UV-TCT. The charge collection efficiency in reverse bias was shown to scale directly with the 1 MeV equivalent fluence $Φ_{\text{eq}}$ as $\text{CCE} \propto Φ_{\text{eq}}^{-0.63\pm0.01}$. A CCE better than 50% was able to be obtained for fluences up to $1 \times 10^{15}$ n$_{\text{eq}}$/cm$^2$. Because of the low currents in the forward direction, particle detection was also possible in forward bias, where the CCE was found to be increased relative to reverse bias. Furthermore, a significant dependency on the amount of injected charge was observed, with the CCE surpassing 100% in alpha and UV-TCT measurements, requiring further systematic investigation.

机构、总结、中文摘要均由AI分析而来,可能存在错误,请以论文正文为准。

↑