Tao Yang, Yuhang Tan, Qing Liu, Suyu Xiao, Kai Liu, Jianyong Zhang, Ryuta Kiuchi, Mei Zhao, Xiyuan Zhang, Congcong Wang, Boyue Wu, Jianing Lin, Weimin Song, Hai Lu, Xin Shi
We address the determination of the time resolution for the $\rm 100~μm$ 4H-SiC PIN detectors fabricated by Nanjing University (NJU). The time response to $\rm β$ particles from a $\rm ^{90}$Sr source is investigated for the detection of the minimum ionizing particles (MIPs). We study the influence of different reverse voltages, which correspond to different carrier velocities and device sizes, and how this correlates with the detector capacitance. We determine a time resolution $\rm (94\pm1)~ps$ for $\rm 100~μm$ 4H-SiC PIN detector. A fast simulation software, termed RASER (RAdiation SEmiconductoR), is developed, and validated by comparing the waveform obtained from simulated and measured data. The simulated time resolution is $\rm (73\pm 1)~ps$ after considering the intrinsic leading contributions of the detector to time resolution.
4H-SiC PIN detector for alpha particles from room temperature to 90 °C
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Jilin University(吉林大学);Shandong Institute of Advanced Technology(山东高等技术研究院)
Stable Charge Collection and Sub-45 ps Time Resolution in a 4H-SiC PIN Detector Irradiated With Low Fluence 16.5 MeV/u Ta Ions
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Qufu Normal University(曲阜师范大学);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室);Liaoning University(辽宁大学)
Rise Time and Charge Collection Efficiency of Graphene-Optimized 4H-SiC p-i-n Detector
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Liaoning University(辽宁大学);Jilin University(吉林大学);Shandong Institute of Advanced Technology(山东高等技术研究院)
Extraction of Electron and Hole Drift Velocities in thin 4H-SiC PIN Detectors using High-Frequency Readout Electronics
Marietta Blau Institute for Particle Physics, Austrian Academy of Sciences(马里埃塔·布劳粒子物理研究所,奥地利科学院);Institute of Atomic and Subatomic Physics, TU Wien(原子与亚原子物理研究所,维也纳工业大学)
Stability of Charge Collection Efficiency and Time Resolution in a Novel Ultra-fast Graphene-Optimized Silicon Carbide Detector Under X-ray Irradiation
Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);Liaoning University(辽宁大学);Qufu Normal University(曲阜师范大学);Jilin University(吉林大学)
In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams
Marietta Blau Institute for Particle Physics, Austrian Academy of Sciences(玛丽塔·布劳粒子物理研究所,奥地利科学院);Institute of Atomic and Subatomic Physics, TU Wien(维也纳工业大学原子与亚原子物理研究所)
Effects of irradiation by protons, neutrons, and gamma particles on electrical properties of 4H-SiC diodes and LGAD sensors
Institute of Physics of the Czech Academy of Sciences(捷克科学院物理研究所);onsemi(安森美);Faculty of Nuclear Sciences and Physical Engineering, Czech Technical University in Prague(布拉格捷克技术大学核科学与物理工程学院)
Performance Characteristics of the Battery-Operated Si PIN Diode Detector with Integrated Preamplifier and Data Acquisition Module for Fusion Particle Detection
An active Transverse Energy Filter based on microstructured Si-PIN diodes with an angular-selective detection efficiency
University of Münster(明斯特大学);Istituto Nazionale di Fisica Nucleare (INFN) – Sezione di Milano-Bicocca(意大利国家核物理研究所(INFN)米兰-比科卡分部);Kirchhoff-Institute for Physics, University of Heidelberg(海德堡大学基希霍夫物理研究所)
A Timing RPC with low resistive ceramic electrodes
为了精确确定开始时间,德国达姆施塔特反质子和离子研究设施(FAIR)正在为压缩重子物质谱仪(CBM)的飞行时间壁研制束分裂T $_0$计数器(BFTC)。该探测器将位于射束管周围,覆盖射弹旁观者探测器的前部区域。预计该区域的通量将超过10 $^5$ cm $^{-2}$ s $^{-1}$。陶瓷复合电极电阻板电离室(RPC)由于其高倍率性能和材料的抗辐射性而得到广泛应用。在相对论电子高束流条件下的多次实验中,效率$\ge$为97%,时间分辨$\le$为90 ps,速率性能$\ge$为10 $^5$ cm $^{-2}$ s $^{-1}$。我们确认这些特性的稳定性与低电阻的Si $_3$ N $_4$ /SiC浮动电极的原型8个小RPC,其中每个包含6个气隙。活性RPC尺寸为20 $\times$ 20 mm $^2$,基于Al $_3$ O $_2$和Si $_3$ N $_4$ /SiC陶瓷生产。最近的测试结果与相对论电子在亥姆霍兹Zentrum德累斯顿-罗森多夫的线性加速器ELBE与新的PADI-10前端电子将提交。