F. Carnesecchi, G. Vignola, N. Agrawal, A. Alici, P. Antonioli, S. Arcelli, F. Bellini, D. Cavazza, L. Cifarelli, M. Colocci, S. Durando, F. Ercolessi, M. Garbi… 展开作者
F. Carnesecchi, G. Vignola, N. Agrawal, A. Alici, P. Antonioli, S. Arcelli, F. Bellini, D. Cavazza, L. Cifarelli, M. Colocci, S. Durando, F. Ercolessi, M. Garbini, M. Giacalone, D. Hatzifotiadou, N. Jacazio, A. Margotti, G. Malfattore, R. Nania, F. Noferini, O. Pinazza, R. Preghenella, R. Ricci, L. Rignanese, N. Rubini, E. Scapparone, G. Scioli, S. Strazzi, S. Tripathy, A. Zichichi
The direct response of Silicon PhotoMultipliers being traversed by a MIP charged particle have been studied in a systematic way for the first time. Using beam test data, time resolution and the crosstalk probability have been measured. A characterization of the SiPM by means of a laser beam is also reported. The results obtained for different sensors indicate a measured time resolution around 40-70 ps. Although particles are expected to traverse only one SPAD per event, crosstalk measurements on different sensors indicate an unexpected higher value with respect to the one related to the sensor noise.
Efficient and precise Cherenkov-based charged particle timing using SiPMs
Istituto Nazionale di Fisica Nucleare, Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Dipartimento di Fisica “M. Merlin” dell’Università e del Politecnico di Bari(巴里大学与理工大学M. Merlin物理学系)
Measurements of efficiency, timing and response to irradiation for direct detection of charged particles with SiPMs
Museo Storico della Fisica e Centro Studi Enrico Fermi(恩里科·费米物理历史博物馆与研究中心);University of Bologna(博洛尼亚大学);Istituto Nazionale di Fisica Nucleare(意大利国家核物理研究所);Politecnico di Torino(都灵理工大学);Fondazione Bruno Kessler(布鲁诺·凯斯勒基金会);Laboratori Nazionali di Frascati(弗拉斯卡蒂国家实验室)
Beam test studies for a SiPM-based RICH detector prototype for the future ALICE~3 experiment
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系);CERN, the European Organization for Nuclear Research(欧洲核子研究中心);Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México(墨西哥国立自治大学核科学研究所)
Characterization of FBK NUV-HD-Cryo SiPMs near LHe temperature
China Institute of Atomic Energy(中国原子能科学研究院);Brown University(布朗大学);Yalong River Hydropower Development Company, Ltd.(雅砻江流域水电开发有限公司);Jinping Deep Underground Frontier Science and Dark Matter Key Laboratory of Sichuan Province(四川省锦屏深地前沿科学与暗物质重点实验室);Peking University(北京大学);Fondazione Bruno Kessler(布鲁诺·克塞勒基金会)
A 16-ch module for thermal neutron detection using ZnS:${}^6$LiF scintillator with embedded WLS fibers coupled to SiPMs and its dedicated readout electronics
SiPM non-linearity studies in beam tests with scintillating crystals
Tsung-Dao Lee Institute, Shanghai Jiao Tong University(上海交大李政道研究所);Key Laboratory for Particle Astrophysics and Cosmology (MOE), Shanghai Key Laboratory for Particle Physics and Cosmology (SKLPPC), Shanghai Jiao Tong University(上海交通大学粒子天体物理与宇宙学教育部重点实验室/上海粒子物理与宇宙学重点实验室);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);University of Chinese Academy of Sciences(中国科学院大学)
Enhanced Dark Matter Sensitivity using a Hybrid SiPM-SNSPD-Qubit Detector in Liquid Argon
Laboratory of Advanced Technologies and Instruments, IRSRA(IRSRA先进技术与仪器实验室);Institute of Theoretical Physics, INRC(INRC理论物理研究所);Energy Research Center, Al-Nahrain University(纳海林大学能源研究中心);Laboratory of Quantum Information, JINNR(JINNR量子信息实验室)
Characterization of SiPMs at 40 K for neutrino coherent detection based on pure CsI
University of South China(南华大学);Key Laboratory of Advanced Nuclear Energy Design and Safety, Ministry of Education(教育部先进核能设计与安全重点实验室);Institute of High Energy Physics, Chinese Academy of Sciences(中国科学院高能物理研究所);State Key Laboratory of Particle Detection and Electronics(粒子探测与电子学国家重点实验室)
Development of a Cherenkov-Based Time-of-Flight Detector Using Silicon Photomultipliers
Istituto Nazionale di Fisica Nucleare (INFN), Sezione di Bari(意大利国家核物理研究所巴里分部);CERN, European Organization for Nuclear Research(欧洲核子研究组织(CERN));Dipartimento di Fisica dell’Università e del Politecnico di Bari(巴里大学与理工大学物理系)
An FPGA Based energy correction method for one-to-one coupled PET detector: model and evaluation
基于硅光电倍增器(SiPMs)的PET扫描器已经被广泛用作先进的核医学成像技术,其产生局部体内生物学和生物化学的定量图像。SiPM的紧凑尺寸允许闪烁晶体和光电传感器之间的直接一对一耦合,从而产生比必须在光电倍增管(PMT)PET系统中使用的光共享方法更好的定时和能量分辨率。为了减小读出电子设备的体积,具有位置解码器的前端多路复用器是没有高度集成的专用集成电路(ASIC)的一对一系统的常见选择。然而,在这种情况下,我们不能测量每个晶体的沉积能量激发的湮灭光子,所以晶间散射(ICS)事件将导致晶体错位,然后恶化探测器的固有分辨率。此外,考虑到SiPM的增益色散和非线性输出导致的能量窗口内的事件拒绝,需要能量校正机制。然而,缺乏每个晶体的能量信息将引入大的能量校正误差的ICS事件。针对这一问题,本文提出了一种在Kintext-7现场可编程门阵列(FPGA)器件上实现的在线能量校正机制。实验室中的实验使用8 X 8分段LYSO晶体与8 X 8 SiPM(J系列,来自ON Semiconductor)阵列耦合进行,该阵列在22 Na点源激发下。测试结果表明,非ICS和ICS事件的能量都可以精确校正,能量分辨率优于12%。我们还将此方法应用于实际的临床PET扫描仪下的68 Ge线源,以验证其多通道的可靠性。